DEW 40 IHB Installatörshandbok Dockningssats för F750 med VPB 200. Installer manual Docking kit for F750 with VPB 200

Samankaltaiset tiedostot
SCA 40 IHB

DEW 40 IHB Installatörshandbok Dockningssats för F750 med VPB 200. Installer manual Docking kit for F750 with VPB 200

Installatörshandbok SCA 40 IHB SE SE Installatörshandbok Dockningssats. Installer manual Docking kit. Asentajan käsikirja Liitäntäsarja

Installatörshandbok - SCA 41

Asennusohje ilmaiskylmälle NIBE F1145/F1245

Installatörshandbok SCA 41 IHB SE

Asennusohje alashunttaukselle NIBE F1145/F1245

Asentajan käsikirja AXC 40. Lisätarvikkeet IHB FI LEK

SCA 41 IHB

Asennusohje AXC 40 IHB FI AXC 40 IHB FI 1

Asentajan käsikirja AXC 40

Asentajan käsikirja AXC 40. Lisätarvikkeet IHB FI

ASENNUSOHJE IHB FI POOL 40 IHB FI 1

ASENNUSOHJE KÄYTTÖVEDEN LÄMMITYKSEN OHJAUS VST 114/VST 200 MONTERINGSANVISNING VARMVATTENSTYRNING VST 114/VST 200

NIBE F1155/F1255. Elschema. Wiring diagram. Elektrischer Schaltplan IHB SE

Asentajan käsikirja AXC 40

NIBE ILMAVESILÄMPÖPUMPPUOPAS OSA 1: SISÄYKSIKÖT VVM 310 VVM 320 VVM 500

Manual. Linktower Retrofit kit

FJVM FIGHTER 310P/410P/360P

Anvisning till VDM6A för rundpumpning med seriekoppling

ASENNUSOHJE / INSTALLATIONSANVISNINGAR / INSTALLATION INSTRUCTIONS. PA KAIVO SA tarvikeluettelo/ förteckning över utrustning/ list of equipment:

Asentajan käsikirja MCU 40. Lisätarvikkeet. Lisävarustekortti IHB FI

Asentajan käsikirja Vedenpoistoputki KVR 10

Asentajan käsikirja AXC 50. Lisätarvikkeet IHB FI LEK

Arbetsplatsarmatur och badrumsarmatur Work-point and Bathroom luminaire Työpiste- ja kylpyhuonevalaisin. Onndeli Onnsani

NIBE F1155/F1255. Elschema. Wiring diagram. Elektrischer Schaltplan IHB SE LEK

MAALÄMPÖPUMPPUJEN ASENTAJAN OPAS

-BT1 -QM31 -XL15 -HQ1 -EB100 F1145

Swegon CASA Smart Sensor package

TÄYTTÖAUTOMAATIT TÄYTTÖAUTOMAATIT COMPUTER INFLATORS

SOLAR 41. Installatörshandbok SOLAR 41. Installer manual SOLAR 41. Installateurhandbuch SOLAR 41. Asentajan käsikirja SOLAR 41 IHB LEK

INSTALLATIONSGUIDE ASENNUSOHJE. USB 2.0 kort. USB 2.0 kortti

Linear S/SI/SR/P. Asennusohje Monteringsanvisning

National Building Code of Finland, Part D1, Building Water Supply and Sewerage Systems, Regulations and guidelines 2007

Asennusopas. DEVIreg 531. Elektroninen termostaatti.

PIKA- OHJE Jäspi Tehowatti Air Asentajan pikaohje

POISTOILMALÄMPÖPUMPPUJEN ASENTAJAN OPAS

Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Muutokset sallittu vain sertifikaatin my

BRUKSANVISNING KÄYTTÖOHJE

FinFamily PostgreSQL installation ( ) FinFamily PostgreSQL

TW-LTE 4G/3G. USB-modeemi (USB 2.0)

Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Muutokset sallittu vain sertifikaatin my

Liitäntäperiaate. Käyttökohteet Omakotitalot vesikiertoisilla lämmitysjärjestelmillä. Suurin suositeltu lämmitysteho 13,5 kw.

CONVERSION KITS FOR FRAMES MR8 AND MR9 INSTALLATION INSTRUCTIONS

Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Muutokset sallittu vain sertifikaatin my

Recirkulering. El-tilslutning. Kontrolpanel. Dansk. Timerfunktion

CW- suotimen asennusohje CW-filtrets monteringsanvisning

Lab SBS3.FARM_Hyper-V - Navigating a SharePoint site

Vakiomallisten kuumakanavajärjestelmien kytkeminen Wiring of standard hotrunner systems

HOO B00 - B01 HOO B20 - B24

YLEISET OHJEET LÄMMINVESIVARAAJAN ASENNUKSEEN

BRUKSANVISNING KÄYTTÖOHJE

Tehowatti Air PIKA- OHJE. Asentajan pikaohje. Huom.! Lue tämä opas ennen asennusta. Asentamiseen tarvitaan myös laitekohtaisia asentajan ohjeita.

Date Päiväys J.Mikkonen Signature Allekirjoitus. V.Tepponen

LYTH-CONS CONSISTENCY TRANSMITTER

HK 15 FI GB R 15. Käyttö- ja asennusohje HK 15. User and installer manual HK 15 CHB

ver INSTALLATIONSANVISNING/ ASENNUSOHJE Firewire PC-card Tiedonsiirto-ohjain Artikelnr/nro

1. SIT. The handler and dog stop with the dog sitting at heel. When the dog is sitting, the handler cues the dog to heel forward.

Porejärjestelmä. POREJÄRJESTELMÄN KÄYTTÖ TALVELLA (ei koskee Polaria)

PAINEILMALETKUKELA-AUTOMAATTI AUTOMATIC AIR HOSE REEL

LEK LEK ECS 40/ECS 41

ASENTAJAN KÄSIKIRJA. Jäspi Basic jäähdytyspaketti. Kaukora Oy. MCU 40 ohjausautomatiikalla varustettuihin järjestelmiin.

PIKA- OHJE Jäspi Tehowatti Air Asentajan pikaohje

Secto Design Oy Kauppalantie Kauniainen Finland tel fax info@sectodesign.fi

SIRIUS valaisin on asemoitava siten, ettei pitkäaikaista katsomista valaisimeen voi olettaa tapahtuvan 2,3m lähempää.

Exercise 1. (session: )

BRUTTO PINTA- ALA (M 2 ) KEHYKSEN MATERIAAL I. EA-HP-1500/47-18 Super heat ALUMIINI 1, , *1680*110 59

Installation / Asennusohje SO-3396-V

Essence. Asennusohje Monteringsanvisning

Elektronisk Scart-växel SCART-kytkin äänelle ja kuvalle. KÄYTTÖOHJE BRUKSANVISNINGVers:

Asentajan käsikirja AXC 50. Lisätarvikkeet IHB FI

You can check above like this: Start->Control Panel->Programs->find if Microsoft Lync or Microsoft Lync Attendeed is listed

Liitäntäperiaate. Käyttökohteet Kiinteistöt vesikiertoisilla lämmitysjärjestelmillä. Vaihtoehto Lämpöpumppu

Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Muutokset sallittu vain sertifikaatin my

Installation instruction PEM

Asennusohje SpaDealers Löylytynnyri S1800 lisäohje

Solar Water Heater Kit. EcoStyle. 1 User Manual/Operating Instructions. Contents FREE LESSON PLANS AVAILABLE.

INSTALLATIONSGUIDE ASENNUSOHJE

Start Here Start her Aloita tästä Start her Börja här

Fitting instructions. Fitting set for joining all types of DEVI self limiting heating cables to heating cables Art. no SSTL nro

WPS/Reset Hold i 5 sekunder for å automatisk konfigurere med WPS. Hold i 10 Seoncds å tilbakestille WiFi å faktor standardinnstillingene.

WINE COOLER TFW METOS TFW 160S, TFW 365-2S, TFW 375S MG ,

Anvisning till hydrauluttag MF & ANV008 SV

TYÖKALUVAUNU JA YLÄKAAPPI

LEK EXC 40. Installatörshandbok EXC 40. Installer manual EXC 40. Installateurhandbuch EXC 40. Asentajan käsikirja EXC 40 IHB

DEW 40. Dockningssats DEW 40. Docking kit DEW 40. Anschlusssatz DEW 40. Liitäntäsarja DEW 40 IHB

INSTALLATION INSTRUCTION ASENNUSOHJE PEM SJTK31 SJTK46 ENGLISH SUOMI

SPARE PART LIST FINN-POWER. P20X version 1.5. Released 9/2010

AMPLYVOX DOOR ENTRY SYSTEMS, ROOM UNITS

TRIMFENA Ultra Fin FX

SPARE PART LIST VARAOSALUETTELO FINN-POWER P51 MS 1.1 DATE:030403

IRROITETTAVAN ISTUIMEN ASENNUSOHJE LÖSTAGBAR SÄTE MONTERINGS MANUAL REMOVABLE SEAT S INSTALLATION MANUAL

TW- LTE 4G/3G. USB- sovitin (USB 2.0)

PERLAS. Art. No. mirror cabinet / yläkaappi / överskåp basin unit / allaskaappi / underskåp washbasin / pesuallas / handfat

NIBE ILMAVESILÄMPÖPUMPPUOPAS OSA 3: OHJAUSYKSIKÖT SMO 20 SMO 40

Käyttöohjekirja NIBE Uplink

SPARE PART LIST VARAOSALUETTELO FINN-POWER P32X 1.1 DATE:

OFFICE 365 OPISKELIJOILLE

Security server v6 installation requirements

Fonte 16045SAVA 16045VAVA 16045SAVA 16045VAVA ASENNUSOHJE MONTERINGSANVISNING ASSEMBLY INSTRUCTIONS K16045VAK2 K16045SAK1 K16045K3 K16045K3

Transkriptio:

LEK SE GB FI DEW 0 Installatörshandbok Dockningssats för F0 med VPB 00 Installer manual Docking kit for F0 with VPB 00 Asentajan käsikirja Liitäntäsarja F0:lle VPB 00:lla IHB 0-09

LEK Installatörshandbok - DEW 0 Allmänt Detta tillbehör används för att docka en VPB 00 till en F0 i hus där det finns ett stort behov av varmvatten. Denna installatörshandbok, med inkluderade pumpdiagram på sida 9, bygger på att VPB 00 installeras till vänster om F0 (se bild nedan). Innehåll st st st st Tillbehörslåda (apparatlåda) Temperaturgivare Buntband Buntband med clips SE st Växelventil st Backventil st Avstängningsventil mm st O-ringar st Planpackning LEK st Metallclips mm st Metallclips mm TIPS! Se installationshandboken för F0 för mer information om värmepumpen och dess installation. Dokumenten finns att ladda hem på www.nibe.se. st st st st Plastclips Flexrör Vinkelkoppling Förminskningssats - mm st Förstärkningshylsa mm st Klämring mm st Klämringsmutter mm st Plugg R st Plugg mm st Plugg mm st Skruv M

SE Komponentplacering LEK Elkomponenter SF Strömställare AA AA-X AA-X AA-X9 Tillbehörskort Anslutningsplint, givare och extern blockering Anslutningsplint, kommunikation Anslutningsplint, växelventil Beteckningar i komponentplacering enligt standard IEC - och -.

SE Röranslutning varmvatten Principschema Förklaring CP EB00 FQ WP AA BT BT QM0 QN RM VPB 00 F0 Blandningsventil, varmvatten (ingår inte F0 cu) DEW 0 Apparatlåda Temperaturgivare, varmvattenladdning, styrande Temperaturgivare, varmvatten topp, visande Avstängningsventil Växelventil, varmvatten Backventil Beteckningar enligt standard IEC -. Principschema extra varmvatten EB00 -CP -WP -BT -WP -BT -WP-AA -WP-QN GP FQ -WP-RM -WP-QM0 OBS! Detta är ett principschema. Verklig anläggning skall projekteras enligt gällande normer.

SE Allmänt Två flexrör ingår i DEW 0. All övrig rördragning skall ske med mm kopparrör och snäva böjar ska undvikas. Röranslutningar F0 Flexrör. Stäng av värmepumpen och slå av strömmen på säkerhetsbrytaren.. Ta bort frontluckorna enligt beskrivning i värmepumpens installatörshandbok.. Töm F0 på vatten samt släpp trycket i klimatsystemet om värmepumpen blivit installerad tidigare.. Koppla bort anslutningen för inkommande kallvatten, se Installatörshandbok för F0 för ytterligare instruktioner.. Demontera röret ovanför värmebärarpumpen (GP). 9. Demontera backventilen som sitter innanför påfyllningsventilen (QM0) och montera därefter bipackad R-plugg. F0, Koppar F0, rostfri eller emalj. Montera vinkelkoppling på flexröret med honanslutning. Montera medlevererade o-ringar och ett metallclips ( mm).. Montera flexröret och planpackning på värmebärarpumpen (GP).. Montera det andra flexröret i elpatronsanslutningen. Montera medlevererade o-ringar och ett metallclips ( mm). OBS! Backventilen i blandningsventilen i F0 ska demonteras för att det inte ska kunna uppstå undertryck i VPB 00. TÄNK PÅ! För att undvika onödiga värmeförluster bör rören isoleras.

SE Kallvatten F0 cu Om fabriksinställningen ändras så att varmvattentemperaturen kan överstiga 0 C ska blandningsventil monteras, se installatörshandbok för F0. I de fall det inte behövs någon blandningsventil ansluts inkommande kallvatten i anslutning för kallvatten (XL) i VPB 00. -vägskoppling. Demontera plugg i -vägskopplingen.. Den nu lediga anslutningen på -vägskopplingen kopplas samman med dockningssanslutning, returledning (XL9) i VPB 00. Kallvatten F0 rf och emalj. Mellan blandningsventilen (EB00-FQ) och kopplet för inkommande kallvatten finns ett flexrör. Lossa detta flexrör från den övre anslutningen på kopplet.. Plugga anslutningen på kopplet med bipackad plugg ( mm) och dra flexröret bakåt.. Anslut inkommande kallvatten till flexröret. LEK/APH

SE Röranslutningar VPB 00 Växelventil (WP-QN). Montera den bipackade växelventilen nertill i VPB 00.. Anslut flexrören för fram- och returledningen på växelventilen. Port A: Till anslutning för dockning, framledning (XL) i VPB 00. Port B: Till elpatronen i F0. Port AB: Från värmerbärarpumpen (GP) i F0. Anslutningar I de fall det inte finns blandningsventil i F0 ansluts inkommande kallvatten i anslutning för kallvatten (XL) i VPB 00. Montera bipackad avstängningsventil samt backventil på inkommande kallvatten. Dockningsanslutning, returledning (XL9) kopplas samman med -vägskopplingen i F0. LEK

SE Pump- och tryckfallsdiagram Vidstående diagram visar pumpkapacitet med VPB 00 dockad till F0, som i detta fall då ersätter motsvarande diagram i Installatörshandboken för F0. 0 0 0 0 00 90 0 0 0 0 0 0 0 0 0 0 0,0 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 0 0 0 00 90 0 0 0 0 0 0 0 0 0 0 0,0 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 0 0 0 00 90 0 0 0 0 0 0 0 0 0 0 0,0 0, 0, 0, 0, 0, 0, 0, 0, 0, 9

SE Elinkoppling OBS! All elektrisk inkoppling skall ske av behörig elektriker. Elektrisk installation och ledningsdragning skall utföras enligt gällande bestämmelser. Värmepumpen ska vara spänningslös vid installation av DEW 0. Montering av apparatlåda (WP-AA) Montera plåten med apparatlådan i botten av VPB 00. LEK OBS! Om matningskabeln är skadad får den endast ersättas av NIBE, dess serviceombud eller liknande behörig personal för att undvika eventuell fara och skada. OBS! För att undvika störningar får kommunikationsoch/eller givarkablar till externa anslutningar inte förläggas närmare än 0 cm från starkströmsledningar. Elschema finns i slutet av denna Installatörshandbok. 0

LEK 0 9 0 9 0 9 0 9 9 N L PE PE 9 N L PE PE SE Anslutning av kommunikation Detta tillbehör innehåller ett tillbehörskort (AA) som ska anslutas direkt till värmepumpen på ingångskortet (plint AA-X). Om flera tillbehör ska anslutas eller redan finns installerade måste nedanstående instruktion följas. Det första tillbehörskortet ska anslutas direkt till värmepumpens plint AA-X. De efterföljande korten ansluts i serie med föregående kort. Kommunikationskabeln (W0, längd, meter) är monterad från fabrik och ansluts enligt tabellen nedan. Anslutning av matning DEW 0 levereras med matningskabel med stickkontakt (W0, längd,0 meter) monterad från fabrik. Färg Vit (A) Brun (B) Grön (GND) Värmepump (AA-X) Annat tillbehörskort (AA-X) A B GND AA-X A B GND A B GND AA-X -X ON -X -X -X0 -X -X9 A B GND A B GND AA-X -X ON -X -X -X0 -X -X9

ON SE Montering av givare Givare, varmvattenladdning (WP-BT) och varmvatten topp (WP-BT) placeras i därför avsedda dykrör i VPB 00, se bild nedan. Fäst givarkablarna med bifogade plastclips. -X -X 0 9 0 9 -X -X9 9 -X0 -X N L PE PE Anslutning av givare Anslutning av fabriksmonterat kablage De utgående kablagen (W0) och (W0) från apparatlådan (WP-AA) ansluts internt på VPB 00. Kablage (W0) förläggs via baksidan och dras sedan, i därför avsedda spår, upp på framsidan av VPB 00. (W0) ansluts till givare, varmvattenladdning (WP- BT). (W0) anslut till givare, varmvatten topp (WP-BT). LEK Anslutning av växelventil (WP-QN) Den utgående kablaget (W0) från apparatlådan (WP- AA) ansluts till växelventilen (WP-QN). Anslutning av kontakt för extern blockering Om man önskar kunna blockera DEW 0 anslut en potentialfri kontakt till AA-X:-. AA Externt 9 0

SE DIP-switch DIP-switchen (S) på tillbehörskortet (AA) i apparatlådan (WP-AA) ska ställas in enligt nedan. ON S

SE Aktivering av DEW 0 Aktiveringen av DEW 0 kan göras via startguiden eller direkt i menysystemet. Startguiden Startguiden visas vid första uppstart efter värmepumpsinstallationen, men finns även i meny.. Menysystemet Om du inte aktiverar DEW 0 via startguiden kan du göra detta i menysystemet. Meny. - systeminställningar Aktivering/avaktivering av tillbehör. Meny. - serviceinfo Här kan du se om ev. extern blockering av DEW 0 är aktiv. TÄNK PÅ! Se även Installatörshandboken för F0. TÄNK PÅ! Värmepumpens mjukvara skall vara programvaruversion eller senare. Om så inte är fallet, skall en uppdatering av mjukvaran göras. Uppdatering finns tillgänglig på www.nibe.se/programvara, alternativt på USB-minne.

LEK Installer manual - DEW 0 General This accessory is used to dock a F0 to a VPB 00 in houses that have a large hot water demand. This installer manual, with pump diagram on page, is based on VPB 00 being installed to the left of F0 (see image below). Contents x Accessory box (unit box) x x x Temperature sensor Cable ties Cable tie with clips GB x Shuttle valve x Non-return valve x Shut-off valve mm x O-rings x Flat gasket LEK x Metal clips mm x Metal clips mm TIP See installer manual for F0 for more information about the heat pump and its installation. Documentation can be downloaded from www.nibe.se. x x x x Plastic clips Flexible pipe Angle connection Reduction kit - mm x Reinforcement sleeve mm x Compression ring mm x Compression ring nut mm x Plug R x Plug mm x Plug mm x Screw M

GB Component positions LEK Electrical components SF Switch AA AA-X AA-X AA-X9 Accessory card Terminal block, sensors and external blocking Terminal block, communication Terminal block, reversing valve Designations in component locations according to standard IEC - and -.

GB Pipe connection hot water Outline diagram Explanation CP EB00 FQ WP AA BT BT QM0 QN RM VPB 00 F0 Mixing valve, hot water (not included in F0 cu) DEW 0 Unit box Temperature sensor, hot water charging, control Temperature sensor, hot water peak, display Shut-off valve Reversing valve, hot water Non-return valve Designations according to standard IEC -. Outline diagram extra hot water EB00 -CP -WP -BT -WP -BT -WP-AA -WP-QN GP FQ -WP-RM -WP-QM0 Note! This is an outline diagram. Actual installations must be planned according to applicable standards.

GB General Two flexible pipes are included in DEW 0. All other pipe routing must be carried out with mm copper pipes and tight bends must be avoided. Pipe connections F0 Flexible pipe. Shut off the heat pump and turn off the current on the safety breaker.. Remove the front panels according to the description in the heat pump installation manual.. Drain F0 of water and release the pressure in the climate system if the heat pump was previously installed.. Disconnect the connection for incoming cold water, see Installation manual for F0 for further instructions.. Remove the pipe above the heating medium pump (GP). 9. Remove the non-return valve located next to the filler valve (QM0) and then install the enclosed R-plug. F0, Copper F0, enamel or stainless steel. Install the angled connector on the flexible pipe with the female connection. Install enclosed O-rings and a metal clip ( mm).. Install the flexible pipe and flat gasket on the heating medium pump (GP).. Install the other flexible pipe in the immersion heater connection. Install supplied O-rings and a metal clip ( mm). NOTE The non-return valve in the mixing valve in F0 must be removed to prevent a vacuum in VPB 00. Caution To prevent unnecessary heat losses insulate the pipes.

GB Cold water F0 cu If the default setting is changed so that the hot water temperature can exceed 0 C install a mixing valve, see installer' s handbook for F0. In cases where a mixing valve is not required, connect the incoming cold water in the connection for cold water (XL) in VPB 00. -way connector. Remove the plug from the -way coupling.. Connect the now free connection on the -way coupling with the docking connection, return line (XL9) in VPB 00. Cold water F0 stainless steel and enamel. There is a flexible hose between the mixing valve (EB00-FQ) and the coupling for incoming cold water. Detach this flexible hose from the upper connection on the coupling.. Plug the connection on the coupling using the enclosed plug ( mm) and route the flexible hose backwards.. Connect the incoming cold water to the flexible pipe. LEK/APH 9

GB Pipe connections VPB 00 Reversing valve (WP-QN). Install the supplied reversing valve at the bottom on VPB 00.. Connect the flexible pipes for the supply and return lines on the reversing valve. Port A: To connection for docking, supply (XL) in VPB 00. Port B: To immersion heater in F0. Port AB: From heating medium pump (GP) in F0. Connections In cases where there is not a mixing valve in F0, connect the incoming cold water in the connection for cold water (XL) in VPB 00. Install the supplied shut-off valve and non-return valve on the incoming cold water. Connect docking connection, return line (XL9) with the -way connector in F0. LEK 0

GB Pump and pressure drop diagrams The adjacent diagram shows the pump capacity with VPB 00 docked to F0, which, in this case replaces the corresponding diagram in the Installation manual for F0. 0 0 0 0 00 90 0 0 0 0 0 0 0 0 0 0 0,0 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 0 0 0 00 90 0 0 0 0 0 0 0 0 0 0 0,0 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 0 0 0 00 90 0 0 0 0 0 0 0 0 0 0 0,0 0, 0, 0, 0, 0, 0, 0, 0, 0,

GB Electrical connection NOTE All electrical connections must be carried out by an authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. The heat pump must not be powered when installing DEW 0. NOTE If the supply cable is damaged, only NIBE, its service representative or similar authorised person may replace it to prevent any danger and damage. Installing unit box (WP-AA) Install the panel with the unit box at the bottom of VPB 00. LEK NOTE To prevent interference, communication and/or sensor cables to external connections must not be laid closer than 0 cm from high voltage cables. The electrical circuit diagram is at the end of this Installer manual.

LEK 0 9 0 9 0 9 0 9 9 N L PE PE 9 N L PE PE GB Connecting communication This accessory contains an accessories card (AA) that must be connected directly to the heat pump on the input card (terminal block AA-X). If several accessories are to be connected or are already installed, the following instructions must be followed. The first accessory card must be connected directly to the heat pump's terminal block AA-X. The following cards must be connected in series with the previous card. The communication cable (W0, length, metres) is factory fitted and connected according to the table below. Connecting the supply DEW 0 is factory fitted with a power cable with plug (W0, length,0 metres). Colour White (A) Brown (B) Green (GND) Heat pump (AA-X) Another accessory card (AA- X) A B GND AA-X A B GND A B GND AA-X -X ON -X -X -X0 -X -X9 A B GND A B GND AA-X -X ON -X -X -X0 -X -X9

ON GB Installing the sensor Sensor, hot water charging (WP-BT) and hot water peak (WP-BT), placed in the submerged tube in VPB 00, see image below. Secure the sensor cables with enclosed plastic clips. -X -X 0 9 0 9 -X -X9 9 -X0 -X N L PE PE Connecting sensors Connection of factory fitted cables Connect the outgoing cables (W0) and (W0) from the unit box (WP-AA) internally in VPB 00. Route cables (W0) via the rear and then route in the relevant grooves, up to the front of VPB 00. Connect (W0) to sensor, hot water charging (WP- BT). Connect (W0) to sensor, hot water top (WP-BT). LEK Connection of reversing valve (WP-QN) Connect the outgoing cables (W0) from the unit box (WP-AA) to the reversing valve (WP-QN). Connecting switch for external blocking If you wish to block DEW 0 connect a potential free switch to AA-X:-. AA Externt 9 0

GB DIP switch The DIP switch (S) on the accessory card (AA) in the unit box (WP-AA) must be set as follows. ON S

GB Activating DEW 0 Activating DEW 0 can be performed via the start guide or directly in the menu system. Start guide The start guide appears upon first start-up after heat pump installation, but is also found in menu.. Menu system If you do not activate DEW 0 via the start guide, this can be done in the menu system. Menu. - system settings Activating/deactivating of accessories. Menu. - service info Here you can see whether any external blocking of DEW 0 is active. Caution Also see the Installer manual for F0. Caution The heat pump software must be version or later. If it is not, perform a software update. The update is available at www.nibe.se/programvara, alternatively on USB memory.

LEK Asentajan käsikirja - DEW 0 Yleistä Tätä lisävarustetta käytetään VPB 00:n liittämiseen F0-lämpöpumppuun talossa, jossa tarvitaan paljon käyttövettä. Tämä asennusohje ja pumppukäyrästö sivulla perustuu siihen, että VPB 00 asennetaan F0:n vasemmalle puolelle (katso kuva alla). Sisältö kpl kpl kpl kpl kpl kpl kpl kpl kpl Lisävarusterasia (kojerasia) Lämpötila-anturi Nippuside Pidikenippuside Vaihtoventtiili Takaiskuventtiili Sulkuventtiili mm O-renkaat Tasotiiviste FI LEK kpl Metallipidike mm VIHJE! Lisätietoa lämpöpumpusta ja sen asennuksesta on F0:n asennusohjeessa. Asiakirjat voit ladata osoitteesta www.nibe.se. kpl kpl kpl kpl kpl kpl kpl kpl kpl kpl kpl kpl Metallipidike mm Muovipidike Letku Kulmaliitin Supistussarja - mm Vahvistusholkki mm Puserrusrengas mm Puserrusrengasmutteri mm Tulppa R Tulppa mm Tulppa mm Ruuvi M

FI Komponenttien sijainti LEK Sähkökomponentit SF Katkaisin AA AA-X AA-X AA-X9 Lisävarustekortti Liitinrima, anturi ja ulkoinen esto Liitinrima, tiedonsiirto Liitinrima, vaihtoventtiili Komponenttikaavion merkinnät standardin IEC - ja - mukaan.

FI Putkiliitäntä käyttövesi Periaatekaavio Selvitys CP EB00 FQ WP AA BT BT QM0 QN RM VPB 00 F0 Sekoitusventtiili, käyttövesi (ei sisälly F0 cu versioon) DEW 0 Kojerasia Lämpötila-anturi, käyttöveden tuotanto, ohjaava Lämpötila-anturi, yläkäyttövesi, näyttävä Sulkuventtiili Vaihtoventtiili, käyttövesi Takaiskuventtiili Merkinnät standardin IEC - mukaan. Periaatekaavio lisäkäyttövesi EB00 -CP -WP -BT -WP -BT -WP-AA -WP-QN GP FQ -WP-RM -WP-QM0 HUOM! Tämä on periaatekaavio. Todellinen laitteisto on suunniteltava voimassaolevien määräysten ja standardien mukaisesti. 9

FI Yleistä Kaksi letkua sisältyy DEW 0:n toimitukseen. Muut putkiasennukset tulee tehdä mm kupariputkilla. Vältä jyrkkiä mutkia. Putkiliitännät F0 Letku. Kytke lämpöpumppu pois päältä ja katkaise virta turvakytkimellä.. Irrota etuluukut asennusohjeen mukaisesti.. Tyhjennä F0 vedestä ja päästä paine lämmitysjärjestelmästä, jos lämpöpumppu on asennettu aikaisemmin.. Irrota tulevan kylmän veden liitäntä. Katso lisäohjeet F0:n asentajan käsikirjasta.. Irrota putki kiertovesipumpun (GP) päällä. 9. Irrota vastaventtiili täyttöventtiilin (QM0) sisäpuolelta ja asenna mukana toimitettu R-tulppa. F0, Kupari F0, ruostumaton tai emali HUOM!. Asenna kulmaliitin letkuineen. Asenna mukana toimitettua o-rengasta ja metallipidike ( mm). Asenna letku ja tasotiiviste kiertovesipumppuun (GP).. Asenna toinen letku sähkövastusliitäntään. Asenna mukana toimitettua o-rengasta ja metallipidike ( mm) F0:n sekoitusventiilin vastaventtiili pitää irrottaa, jotta VPB 00:een ei synny alipainetta. MUISTA! Tarpeettomien lämpöhäviöiden välttämiseksi putket tulee eristää. 0

FI Kylmä vesi F0 cu Sekoitusventtiili on asennettava, jos asetuksia muutetaan niin, että lämpötila voi nousta yli 0 C, katso F0:n asennusohje. Jos sekoitusventiiliä ei tarvita, kylmän veden syöttö liitetään VPB 00:n kylmävesiliitäntään (XL). -tieliitäntä. Irrota tulppa -tieliitännästä.. Liitä -tieliitännän vapaa liitäntä VPB 00:n paluuliitäntään (XL9). Kylmä vesi F0 ruostumaton ja emali. Sekoitusventtiilin ja (EB00-FQ) ja kylmävesisyöttöliitännän välillä on letku. Irrota tämä letku ylemmästä liitännästä.. Tulppaa liitäntä tulpalla ( mm) ja vedä letkua taaksepäin.. Liitä kylmävesisyöttö letkuun. LEK/APH

FI Putkiliitännät VPB 00 Vaihtoventtiili (WP-QN). Asenna mukana toimitettu vaihtoventtiili VPB 00:n alaosaan.. Liitä meno- ja paluuletkut vaihtoventtiiliin. Portti A: Menoliitäntään (XL) VPB 00:ssa. Portti B: Sähkövastukselle F0:ssa Portti AB: Kiertovesipumpusta ((GP)) F0:ssa Liitännät Jos F0:ssa ei ole sekoitusventtiiliä, kylmän veden syöttö liitetään VPB 00:n kylmävesiliitäntään (XL). Asenna sulkuventtiili ja vastaventtiili kylmän veden syöttöön. Paluuliitäntä (XL9) liitetään F0:n -tieliitäntään. LEK

FI Pumppu- ja painehäviökäyrä Oheisessa käyrästössä näkyy pumpun tuotto, kun VPB 00 on liitetty F0:een. Se korvaa korvaa tässä tapauksessa vastaavan käyrästön F0:n asentajan käsikirjassa. 0 0 0 0 00 90 0 0 0 0 0 0 0 0 0 0 0,0 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 0 0 0 00 90 0 0 0 0 0 0 0 0 0 0 0,0 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 0 0 0 00 90 0 0 0 0 0 0 0 0 0 0 0,0 0, 0, 0, 0, 0, 0, 0, 0, 0,

FI Sähköasennukset HUOM! Sähköasennukset saa tehdä vain valtuutettu sähköasentaja. Sähköasennukset ja johtimien veto on tehtävä voimassa olevien määräysten mukaisesti. Lämpöpumpun pitää olla jännitteetön DEW 0:n asennuksen aikana. Kojerasian (WP-AA) asennus Asenna levy kojerasioineen VPB 00:n pohjalle. LEK HUOM! Jos syöttökaapeli vahingoittuu, sen saa vaihtaa vain NIBE, valmistajan huoltoedustaja tai vastaava pätevä ammattilainen vaaran välttämiseksi. HUOM! Häiriöiden välttämiseksi ulkoisten liitäntöjen tiedonsiirto- ja/tai anturikaapeleita ei saa asentaa alle 0 cm etäisyydelle vahvavirtakaapeleista. Kytkentäkaavio on tämän asennusohjeen lopussa.

LEK 0 9 0 9 0 9 0 9 9 N L PE PE 9 N L PE PE FI Tiedonsiirron kytkentä Tämä lisävaruste sisältää lisävarustekortin (AA), joka kytketään suoraan lämpöpumpun tulokorttiin (liitin AA- X). Jos olet kytkemässä useita lisävarusteita tai niitä on jo asennettu, sinun täytyy noudattaa alla olevia ohjeita. Ensimmäinen lisävarustekortti asennetaan suoraan lämpöpumpun liittimeen AA-X. Seuraavat kortit asennetaan sarjaan edellisen kanssa. Tiedonsiirtokaapeli (W0, pituus, m) on asennettu tehtaalla ja kytketään taulukon mukaan. Syöttöjännitteen kytkeminen DEW 0:n mukana toimitetaan pistotulpalla varustettu virtajohto (W0, pituus,0 m). Väri Valkoinen (A) Ruskea (B) Vihreä (GND) Lämpöpumppu (AA-X) Toinen lisävarustekortti (AA- X) A B GND AA-X A B GND A B GND AA-X -X ON -X -X -X0 -X -X9 A B GND A B GND AA-X -X ON -X -X -X0 -X -X9

ON FI Anturien kytkeminen Anturi, käyttöveden lataus (WP-BT) ja käyttövesi, yläosa (WP-BT) asennetaan anturiputkiinsa VPB 00:ssa, katso kuva alla. Kiinnitä anturikaapelit muovipidikkeillä. -X -X 0 9 0 9 -X -X9 9 -X0 -X N L PE PE Anturien kytkeminen LEK Tehdasasennetun kaapelin kytkentä Kojerasiasta (WP-AA) lähtevät kaapelit (W0) ja (W0) asennetaan ja kytketään VPB 00:een. Kaapelit (W0) vedetään takakautta ja sitten niille tarkoitetuissa urissa ylös VPB 00:n etusivulla. (W0) kytketään käyttöveden latausanturiin (WP- BT). (W0) kytketään yläkäyttövesianturiin (WP-BT). Vaihtoventtiilin kytkentä (WP-QN) Kojerasiasta (WP-AA) lähtevät kaapelit (W0) kytketään vaihtoventtiiliin (WP-QN). Ulkoisen estokoskettimen kytkeminen Jos halutaan DEW 0:n estomahdollisuus, kytke potentiaalivapaa kosketin välille AA-X:-. AA Externt 9 0

FI DIP-kytkin Kojerasian (WP-AA) lisävarustekortin (AA) DIP-kytkimet (S) pitää asettaa alla olevan mukaan. ON S

FI DEW 0:n aktivointi DEW 0:n aktivointi voidaan tehdä aloitusoppaan kautta tai suoraan valikkojärjestelmässä. Aloitusopas Aloitusopas näytetään ensimmäisen käynnistyksen yhteydessä lämpöpumpun asennuksen jälkeen, mutta se löytyy myös valikosta.. Valikkojärjestelmä Ellet aktivoi DEW 0:tä aloitusoppaan kautta, voit tehdä sen valikkojärjestelmässä. Valikko. - järjestelmäasetukset Lisävarusteiden aktivointi/deaktivointi. Valikko. - huoltotiedot Tässä voit nähdä, onko DEW 0:n mahdollinen ulkoinen esto aktiivinen. MUISTA! Katso myös F0:n asentajan käsikirja. MUISTA! Lämpöpumpun ohjelmistoversion pitää olla tai uudempi. Ellei näin ole, ohjelmisto pitää päivittää. Ohjelmiston voi päivittää osoitteesta www.nibe.se/programvara tai USB-muistilta.

FI 9

0 Elschema/Wiring diagram/sähkökytkentäkaavio

NIBE AB Sweden Hannabadsvägen Box SE- Markaryd Phone + 000 Telefax + 90 info@nibe.se www.nibe.se 09