Installatörshandbok ELK 42. Installatörshandbok Elkassett. SMO 20, SMO 40 Installer manual Immersion heater. Installateurhandbuch Elektroheizkassette



Samankaltaiset tiedostot
Installatörshandbok ELK 42. Installatörshandbok Elkassett. SMO 20, SMO 40 Installer manual Immersion heater. Installateurhandbuch Elektroheizkassette

Installatörshandbok ELK 26. Installatörshandbok Elkassett. SMO 20, SMO 40 Installer manual Immersion heater. Installateurhandbuch Elektroheizkassette

ELK 42. Installatörshandbok Elkassett SE. Installer manual Immersion heater GB. Installateurhandbuch Elektroheizkassette DE

NIBE F1155/F1255. Elschema. Wiring diagram. Elektrischer Schaltplan IHB SE

Asentajan käsikirja AXC 40. Lisätarvikkeet IHB FI LEK

JÄMÄ STAR RST. Energiamerkintä ja kierrätys. Energimärkning och återvinning. Energy labelling and recovery TIF LEK

LEK EXC 40. Installatörshandbok EXC 40. Installer manual EXC 40. Installateurhandbuch EXC 40. Asentajan käsikirja EXC 40 IHB

Asentajan käsikirja AXC 40. Lisätarvikkeet IHB FI

NIBE ILMAVESILÄMPÖPUMPPUOPAS OSA 1: SISÄYKSIKÖT VVM 310 VVM 320 VVM 500

Asennusohje AXC 40 IHB FI AXC 40 IHB FI 1

LEK LEK ECS 40/ECS 41

NIBE F1155/F1255. Elschema. Wiring diagram. Elektrischer Schaltplan IHB SE LEK

Asennusohje alashunttaukselle NIBE F1145/F1245

ASENNUSOHJE KÄYTTÖVEDEN LÄMMITYKSEN OHJAUS VST 114/VST 200 MONTERINGSANVISNING VARMVATTENSTYRNING VST 114/VST 200

Asentajan käsikirja AXC 40

-BT1 -QM31 -XL15 -HQ1 -EB100 F1145

Asentajan käsikirja AXC 40

SOLAR 41. Installatörshandbok SOLAR 41. Installer manual SOLAR 41. Installateurhandbuch SOLAR 41. Asentajan käsikirja SOLAR 41 IHB LEK

ASENNUSOHJE IHB FI POOL 40 IHB FI 1

Asennusohje ilmaiskylmälle NIBE F1145/F1245

FJVM FIGHTER 310P/410P/360P

Liitäntäperiaate. Käyttökohteet Omakotitalot vesikiertoisilla lämmitysjärjestelmillä. Suurin suositeltu lämmitysteho 13,5 kw.

ELK ELK 26 LEK

Anvisning till VDM6A för rundpumpning med seriekoppling

Alfa Q TW 56W Alfa Q 58W GLAQTW00056 GLAQ W 58 W 5300 lm 5400 lm

NIBE ILMAVESILÄMPÖPUMPPUOPAS OSA 3: OHJAUSYKSIKÖT SMO 20 SMO 40

KVR 10. Installatörshandbok Kondensvattenrör KVR 10. Installer manual Kondensvattenrör KVR 10. Installateurhandbuch Kondensvattenrör KVR 10

Asentajan käsikirja MCU 40. Lisätarvikkeet. Lisävarustekortti IHB FI

SIRIUS valaisin on asemoitava siten, ettei pitkäaikaista katsomista valaisimeen voi olettaa tapahtuvan 2,3m lähempää.

SQUARE. Greenled Tarjusojantie Kempele FINLAND

Asentajan käsikirja Vedenpoistoputki KVR 10

LYTH-CONS CONSISTENCY TRANSMITTER

Käyttöohjekirja. Huolto. Yleistä. Varoventtiili

MODBUS 40. Installatörshandbok Kommunikationsmodul F370, F470, F750, SMO 40, VVM 310, VVM 320, VVM 325, VVM 500 Installer manual Communications module

IR3000, IR4500, IR6000

Exercise 1. (session: )

Asentajan käsikirja AXC 50. Lisätarvikkeet IHB FI LEK

MONTERINGSANVISNING EXTRA SHUNT ESV 22 TILL NIBE SPLIT INSTALLATION INSTRUCTIONS EXTRA SHUNT ESV 22 FOR NIBE SPLIT

ELECTRIC SAUNA HEATERS. Experience the Genuine Finnish Sauna. Experience SAWO.

DEW 40 IHB Installatörshandbok Dockningssats för F750 med VPB 200. Installer manual Docking kit for F750 with VPB 200

DEW 40 IHB Installatörshandbok Dockningssats för F750 med VPB 200. Installer manual Docking kit for F750 with VPB 200

Puhalluslämmitin. Warmex

National Building Code of Finland, Part D1, Building Water Supply and Sewerage Systems, Regulations and guidelines 2007

Røgalarm CCTSA53200 Almost invisible Smokealarm CCTSA53200 Almost invisible (Cavius type 2001-TK001)

ASENNUSOHJE / INSTALLATIONSANVISNINGAR / INSTALLATION INSTRUCTIONS. PA KAIVO SA tarvikeluettelo/ förteckning över utrustning/ list of equipment:

Elektra V GB NO DE PL

ECO E II. Greenled Tarjusojantie Kempele FINLAND

Kytkentäperiaate Soveltuvuus Kiinteistöt, joissa on vesikiertoinen lämmitysjärjestelmä.

Varaosaluettelo Rerservdelslista Spare parts list Ersatzteilliste. [Type text]

Yhtiön nimi: - Luotu: - Puhelin: - Fax: - Päiväys: -

EMK 300. Energimätarkit EMK 300. Energy meter kit EMK 300. Energimesssatz EMK 300. Energimålersæt EMK 300. Energiamittarisarja EMK 300

Arbetsplatsarmatur och badrumsarmatur Work-point and Bathroom luminaire Työpiste- ja kylpyhuonevalaisin. Onndeli Onnsani

I-VALO LED 6721 RETROFIT instructions

performance DHW coil type exchanger Diverter valve Analogue thermostat control panel Heating pump DHW pump Digital electronic control panel

SCA 41 IHB

LEK LEK ECS 40/ECS 41

1. SIT. The handler and dog stop with the dog sitting at heel. When the dog is sitting, the handler cues the dog to heel forward.

SPARE PART LIST FINN-POWER. P20X version 1.5. Released 9/2010

Lapuan myöntämä EU tuki SOLUTION asuinalueille omakoti- tai rivitaloa rakentaville

BRUTTO PINTA- ALA (M 2 ) KEHYKSEN MATERIAAL I. EA-HP-1500/47-18 Super heat ALUMIINI 1, , *1680*110 59

Installatörshandbok - SCA 41

PIKA- OHJE Jäspi Tehowatti Air Asentajan pikaohje

Installatörshandbok SCA 41 IHB SE

Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Muutokset sallittu vain sertifikaatin my

Liitäntäperiaate. Käyttökohteet Kiinteistöt vesikiertoisilla lämmitysjärjestelmillä. Vaihtoehto Lämpöpumppu

mini Safe by Design and optimized for tilting windows

5 Energiatehokkuus ja suorituskyky

KONEISTUSKOKOONPANON TEKEMINEN NX10-YMPÄRISTÖSSÄ

POOL 310. Installatörshandbok Dockningssats pool. Installer manual Docking kit pool. Installateurhandbuch Anschlusssatz Pool

Asennus, käyttö ja huolto

PCS 44 IHB LEK Type UPS P/N: LEK LEK. Max. 10bar TF 110 IP 44. Class H PC;0017NIB

Thermozone AD 102/103

IRROITETTAVAN ISTUIMEN ASENNUSOHJE LÖSTAGBAR SÄTE MONTERINGS MANUAL REMOVABLE SEAT S INSTALLATION MANUAL

HK 15 FI GB R 15. Käyttö- ja asennusohje HK 15. User and installer manual HK 15 CHB

LTY17, LTY17C Lisätehoyksikkö Extra effektenhet

ELK ELK 42 LEK

CONVERSION KITS FOR FRAMES MR8 AND MR9 INSTALLATION INSTRUCTIONS

MODBUS 40. Installatörshandbok Kommunikationsmodul F370, F470, F750, SMO 40, VVM 310, VVM 320, VVM 325, VVM 500 Installer manual Communications module

MOS FI ASENNUS- JA HOITO-OHJEET ELK ELK 26 LEK

Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Muutokset sallittu vain sertifikaatin my

Asennusopas. DEVIreg 531. Elektroninen termostaatti.

FinFamily PostgreSQL installation ( ) FinFamily PostgreSQL

5kW, 6kW, 8kW, 10kW, 14kW, 16kW model. Ilma-vesilämpöpumppu WATERSTAGE

Suihkunurkka Shower enclosure / Duschhörna

HOO B00 - B01 HOO B20 - B24

F2015/F2016/F2025/F2026/F2030/F2300

Date Päiväys J.Mikkonen Signature Allekirjoitus. V.Tepponen

DESIGN NEWS MATTI MÄKINEN EIN DESIGNER IN ANGEBOT WIE LOCKEN WIR DEN GEIST IN DIE FLASCHE?

INSTALLATIONSGUIDE ASENNUSOHJE. USB 2.0 kort. USB 2.0 kortti

SCA 40 IHB

STEF STOF CE... 9!, 2-.,. Version Fläkt Woods Oy

Svenska, Installatörshandbok - PCS 44

Elhah listavalaisin. Made in Finland. Pidätämme oikeuden tuotemuutoksiin.

LK Sähkökattila - 4,5

paranee oleellisesti.

Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Muutokset sallittu vain sertifikaatin my

Provides power to the aerial amplifier when power supply is missing from a satellite receiver box or TV.

Käyttö- ja asennusohje HM 150, 230, 300

Asennus- ja käyttöohje

Suihkunurkka ja -seinä. Shower corner and walls Duschhörna och duschvägg

Transkriptio:

Installatörshandbok SE GB DE FI Installatörshandbok Elkassett för NIBE F1145, F1155, F1255, F1345, VVM 500, SMO 20, SMO 40 Installer manual Immersion heater for NIBE F1145, F1155, F1255, F1345, VVM 500, SMO 20, SMO 40 Installateurhandbuch Elektroheizkassette für NIBE F1145, F1155, F1255, F1345, VVM 500, SMO 20, SMO 40 Asentajan käsikirja Sähkövastus laitteille NIBE F1145, F1155, F1255, F1345, VVM 500, SMO 20, SMO 40 LEK IHB SE 1528-3 331550

Innehållsförteckning 1 Svenska, IHB - Allmänt Uppställning Komponentplacering Röranslutning Elinkoppling 2 2 2 3 4 6 Aufstellung Position der Komponenten Rohranschluss/Durchflussmesser Elektrischer Anschluss Aktivierung von Technische Daten 24 25 26 28 31 32 Aktivering av Tekniska uppgifter 1 English, IHB, General Assembly Component positions Pipe connections Electrical connection 9 10 13 13 13 14 15 17 1 Suomi, IHB - Yleistä Asennus Komponenttien sijainti Putkiliitäntä Sähköasennukset :n aktivointi Tekniset tiedot 35 35 35 36 37 39 42 43 Activating Technical data 1 Deutsch, IHB - 20 21 24 1 Elschema/Wiring diagram/elektrischer schaltplan/elektrisch schema 46 Allgemeines 24 Innehållsförteckning 1

LEK SE Svenska, IHB - Allmänt är en elkassett som kan användas för att komplettera uppvärmningskapaciteten i din NIBE klimatanläggning. När värmebehovet är större än klimatanläggningens kapacitet kopplas elkassetten automatiskt in. Elutrustningen är anpassad till klimatanläggningens funktion. Elkassetten är i princip en elpatron monterad i en vattenbehållare eller en elpanna utan varmvattenberedare. De rostfria elslingorna och elpannetuben är gjorda av syrafast stål (SIS 2333) vilket ger en mycket bra livslängd. Tack vare en liten vattenvolym och en välisolerad kassett ger väldigt små värmeförluster. Uppställning Elkassetten ska monteras stående (se bild nedan). För service erfodras ett fritt utrymme på 500 mm framför kassetten. Om detta inte är möjligt ska demonterbara kopplingar användas. Kompatibla produkter Beroende på vilken produkt ska användas mot ser inkopplingen ut på olika sätt. Dessa produkter kan kopplas in direkt till : F1345 SMO 20 SMO 40 Dessa produkter kräver tillbehöret AXC 40: F1145 F1155 F1255 VVM 500 kräver tillbehöret DEH 500. Innehåll 1 st Elkassett 2

SE Komponentplacering Komponentista EB1, EB20 FA1 FD1, FD4 QA1 Elpatron Automatsäkring Överhettningsskydd Anslutningsplint, inkommande Kopplingsplint Kontaktor 6,0 (-K1) FD1 FD4 RF1 FA1 QA1 QM60 BT30 QM61 X EB1 QA2 QA3 QA41 Kontaktor 12,0 (-K2) Kontaktor 24,0 (-K3) Kontaktor, överhettningsskydd (-K4) QA2 QA3 QA41 EB20 X QA42 Kontaktor, överhettningsskydd (-K5) QA42 UB1 BT30 RF1 X Reservlägestermostat Avstörningskondensator Anslutning framledning, G 40 LEK UB2 PF1 X Anslutning returledning, G 40 UB1, UB2 Kabelgenomföring QM60, QM61 Avluftning PF1 Dataskylt 3

SE Röranslutning Allmänt Rörinstallationen ska utföras enlig gällande normer. Cirkulationspump ska användas för att säkerställa flödet över elpatronen. Om värmesystemets ventiler kan stänga cirkulationen helt ska bypassventil installeras för att flödet genom elkassetten inte ska upphöra. Vid sluten anläggning ska godkänd säkerhetsventil installeras samt tryckexpansionskärl. TÄNK PÅ! Se även installatörshandboken för din värmepump/inomhusmodul. OBS! Avtappning Rörsystemet ska vara urspolat innan elkassetten ansluts så att föroreningar inte skadar ingående komponenter. Systemet töms lättast genom att montera en avtappningsventil på rörinstallationens lägsta punkt. Kvarvarande vatten i töms genom returledningsanslutning (X), se "Komponentplacering" på sida 3. Används returledningsanslutningen på normalt för avtappning av anläggningen monteras här lämpligen en avtappningsventil. Tryckfallsdiagram 9 kpa 8 7 6 5 4 3 2 1 0 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Flöde l/h 4

SE Systemprincip TIPS! Se www.nibe.se/dockning för fullständiga dockningsprinciper. Förklaring EB1 CM4 F QM40 - QM41 RN11 GP10 RM5 BT25 BT71 Elkassett Expansionskärl Säkerhetsventil Avstängningsventiler Reglerventil Cirkulationspump Backventil Framledningsgivare Returledningsgivare Beteckningar i komponentplacering enligt standard IEC 81346-1 och 81346-2. Systemprincip -F -CM4 -EB1 -QM40 -QM41 -RN11 -RM5 -BT25 -BT71 -GP10 Värmepump/ Inomhusmodul OBS! Detta är ett principschema. Verklig anläggning ska projekteras enligt gällande normer. 5

SE Elinkoppling OBS! All elektrisk inkoppling skall ske av behörig elektriker. Elektrisk installation och ledningsdragning skall utföras enligt gällande bestämmelser. Klimatanläggningen ska vara spänningslös vid installation av. ska installeras via allpolig arbetsbrytare med minst 3 mm brytaravstånd. innehåller överhettningsskydd samt kontaktorer för att externt kunna styra de tre effektstegen 6, 12 och 24. För bästa funktion bör effekten binärstyras, det vill säga 6, 12, 18, 24, 30, 36 och 42. Elschema finns i slutet av denna installatörshandbok. Elkopplingsversioner F1345 F1345 har olika elinkopplingar beroende på när värmepumpen tillverkades. För att se vilken elinkoppling som gäller för din F1345, kontrollera om beteckningen "2.0" syns ovanför plintarnas högra sida enligt bild. Utan termostat, tre aktiva elsteg 42 elpatronsteg aktivt. Värmepump F1345 X3 5 6 7 8 9 1 2 3 4 5 6 Med termostat, tre aktiva elsteg 42 elpatronsteg aktivt. 24 elpatronsteg i reservläge. 5 6 7 8 9 1 2 3 4 5 6 X3 X3 X4 X4 1 2 3 Värmepump F1345 F1345 utan 2.0 Plint i ansluts till plintarna -X4 i värmepumpen enligt bild. X3 X4 LEK 6

SE F1345 med 2.0 Plint i ansluts till plintarna X5, X7 och X8 på ingångskortet AA101 i värmepumpen enligt bild. -FC1 -AA101 -AA101 -AA101 -X3 -X4 -X5 N 1 2 3 1 2 3 4 5 6 7 8 9 X5 X7 X8 -AA101 -X6 1 2 3 4 5 6 7 8 9 -AA101 -AA101 -AA101 -X7 -X8 - -AA101-0 1 2 3 4 1 2 3 1 2 3 1 2 3 4 5 Utan termostat, tre aktiva elsteg 42 elpatronsteg aktivt. 6 7 8 9 10 11 12131415 16171819 20 2122 X5 X5 X7 X7 2.0 -AA3 -AA3 -AA3 -X6 2 3 4 5 6 7 8 9 10 11 12131415 16 17 18-2 -3 1 2 3 4 5 6 1 2 3 4 -AA3 2-0 -1 1 3 123 L N L L L N N N L N L N QN10 GP16 C K1 K2 K3 C NO NC K4 C NO NC -AA3-X7 A B A B 12V A B 0-10V 13 14 -GP16 -BE1 -BE2 -BE3 AUX 4 AUX 5 -BT1 -BT50 -BT25 -BT6 AUX 1 AUX 2 AUX 3 -BT7 -BT71 -EP14 -EP15 -BF1 Värmepump F1345 2.0 Med termostat, tre aktiva elsteg 42 elpatronsteg aktivt. 24 elpatronsteg i reservläge. X5 X7 X8 X5 X7 X8 1 2 3 4 5 6 1 2 3 4 1 2 3 Värmepump F1345 2.0 7

SE SMO 20 och SMO 40 Plint i ansluts till plintarna och AA7- i styrmodulen enligt bild. - 123456 F1145, F1155, F1255 och VVM 500 För inkoppling av till ovanstående produkter krävs ett tillbehör. Se avsnittet "Allmänt" på sida 2 för att se vilket tillbehör som behövs för din klimatanläggning. Plint i ansluts till plint och 0 på tillbehörskortet enligt bild. - 1 2 3 4 5 6 AA7-0 1 2 3 4 5 0 2 6 7 8 9 LEK Tillbehörskort L N 1 1 0 2 3 4 Utan termostat, tre aktiva elsteg 42 elpatronsteg aktivt. AA7- AA7: 1 2 3 4 5 6 1 0 2 3 4 Styrmodul SMO Med termostat, tre aktiva elsteg 42 elpatronsteg aktivt. 24 elpatronsteg i reservläge. AA7- AA7: 1 2 3 4 5 6 1 0 2 3 4 Styrmodul SMO 8

SE Aktivering av Menyinställningen av kan göras via startguiden eller direkt i menysystemet. TÄNK PÅ! Se även installatörshandboken för produkten som ska anslutas till. Startguiden Startguiden visas vid första uppstart efter värmepumpsinstallationen, men finns även i meny 5.7. Menysystemet F1345, SMO 20 och SMO 40 Meny 4.9.3 - gradminutinställning Här väljer du när tillsatsen ska starta. Meny 5.1.12 - tillsats Inställning av: Max antal tillåtna tillsatssteg. Om binär stegning ska användas. F1145, F1155, F1255 och VVM 500 Information om menyinställningar för ovanstående produkter finns i manualerna för AXC 40 och DEH 500. Se avsnittet "Allmänt" på sida 2 för att se vilket tillbehör som behövs för din produkt. 9

SE Tekniska uppgifter Mått Alla mått är i millimeter. 400 350 75 100 85 210 350 700 10

SE Tekniska data IP 44 Elektriska data Märkspänning Effekt elpatron Avsäkring elpatron Kapslingsklass Värmebärarkrets Max tillåtet tryck i pannan Min flöde Max flöde Mått och vikt Bredd Djup Höjd Vikt Volym Övrigt Material elpatron Material tub RSK nr Art nr V A MPa/bar l/h l/h mm mm mm kg liter 3 x 400 V ~ 50 Hz 42 63 IP 44 0,7/7 1800 5400 350 400 700 30 4,5 SIS 2333 EN 1.4301 SIS 2333 EN 1.4301 624 07 89 067 075 Energimärkning Informationsblad Tillverkare Modell NIBE Effektivitetsklass rumsuppvärmning Nominell värmeeffekt (Pdesign) Säsongsmedelverkningsgrad rumsuppvärmning Ljudeffektnivå L WA inomhus % db D 42 36,9 35 11

SE Teknisk dokumentation Modell Kondenserande panna Lågtemperatur-panna Panna av typ B11 Kraftvärmepanna Panna med inbyggd tappvarmvattenberedning Tillämpade standarder Nominell avgiven värmeeffekt Prated För pannor för central rumsuppvärmning och pannor med inbyggd tappvarmvattenberedning: Nyttiggjord avgiven värme Vid nominell avgiven värmeeffekt och högtemperaturdrift Vid 30 % av nominell avgiven värmeeffekt och lågtemperaturdrift P 4 P 1 Ja Ja Ja Ja Ja 42 42 Nej Nej Nej Nej Nej Säsongsmedelverkningsgrad för rumsuppvärmning ƞ s 36,9 För pannor för central rumsuppvärmning och pannor med inbyggd tappvarmvattenberedning: Nyttoverkningsgrad Vid nominell avgiven värmeeffekt och högtemperaturdrift Vid 30 % av nominell avgiven värmeeffekt och lågtemperaturdrift ƞ 4 ƞ 1 40 % % % Tillsatselförbrukning Vid full belastning Vid delbelastning Standbyläge elmax elmin P SB 0,01 Övriga poster Varmhållningsförlust Tändbrännarens energiförbrukning Årlig energiförbrukning Ljudeffektnivå, inomhus P stby P ign Q HE L WA 0,2 35 h db För pannor med inbyggd tappvarmvattenberedning Deklarerad tapprofil varmvattenberedning Daglig energiförbrukning Q elec Årlig energiförbrukning AEC h h Energieffektivitet varmvattenberedning Daglig bränsleförbrukning Årlig bränsleförbrukning ƞ wh Q fuel AFC % h GJ 12

LEK English, IHB, GB General is an electric heater that can be used to supplement the heating capacity of your NIBE climate unit. When the heating demand is greater than the climate unit's capacity, the electric heater connects automatically. The electrical equipment is adapted to the climate unit's function. The electric heater is in principle an immersion heater mounted in a water container or an electric boiler without a water heater. The stainless steel electric coils and electric boiler tube are made of stainless steel (SIS 2333) which gives a very good service life. Thanks to a small water volume and a well-insulated electrical heater, has very small heat losses. Assembly The electric heater must be installed upright (see image below). Free space of 500 mm is required in front of the water heater for service. If this is not possible, detachable connections must be used. Compatible products Connection is different depending on which product is to be used with. These products can be connected directly to : F1345 SMO 20 SMO 40 These products require the accessory AXC 40: F1145 F1155 F1255 VVM 500 requires the accessory DEH 500. Contents 1 x Immersion heater 13

GB Component positions Component list EB1, EB20 FA1 FD1, FD4 QA1 Immersion heater Miniature circuit-breaker Overheat protection Terminal block, incoming Terminal block Contactor 6,0 (-K1) FD1 FD4 RF1 FA1 QA1 QM60 BT30 QM61 X EB1 QA2 QA3 QA41 Contactor 12,0 (-K2) Contactor 24,0 (-K3) Contactor, overheat protection (-K4) QA2 QA3 QA41 EB20 X QA42 Contactor, overheat protection (-K5) QA42 UB1 BT30 RF1 X Emergency mode thermostat Suppression capacitor Connection supply line, G 40 LEK UB2 PF1 X Connection return line, G 40 UB1, UB2 Cable gland QM60, QM61 Venting PF1 Rating plate 14

GB Pipe connections General The pipe installation must be carried out in accordance with applicable standards. A circulation pump must be used to ensure the flow over the immersion heater. If the heating system valves can close the circulation completely, the bypass valve must be installed so that the flow through the electric heater does not stop. In closed installations an approved safety valve and pressure expansion vessel must be used. Caution Also see the installer manual for your heat pump/indoor module. Draining NOTE The pipe work must be flushed before the electric heater is connected, so that any contaminants do not damage the component parts. The system is most easily drained by installing a drainage valve at the lowest point on the pipe installation. The remaining water in is drained through the return line connection (X), see "Component location" on page 14. If the return line connection on is normally used for draining the unit, a drain valve can be installed here. Pressure drop diagram 9 kpa 8 7 6 5 4 3 2 1 0 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Flow l/h 15

GB System diagram TIP See www.nibe.se/dockning for complete docking principles. Explanation EB1 CM4 F QM40 - QM41 RN11 GP10 RM5 BT25 BT71 Electric heater Expansion vessel Safety valve Shut off valves Control valve Circulation pump Non-return valve Flow line sensor Return line sensor Designations in component locations according to standard IEC 81346-1 and 81346-2. System diagram -F -CM4 -EB1 -QM40 -QM41 -RN11 -RM5 -BT25 -BT71 -GP10 Värmepump/ Heat Indoor module Inomhusmodul NOTE This is an outline diagram. Actual installations must be planned according to applicable standards. 16

GB Electrical connection NOTE All electrical connections must be carried out by an authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. The climate unit must not be powered when installing. must be installed via a circuit breaker with a minimum breaking gap of 3mm. contains overheat protection and contactors for external control of the three power stages 6, 12 and 24. For best function the power should be binary controlled, that is to say 6, 12, 18, 24, 30, 36 and 42. The electrical circuit diagram is at the end of this Installer handbook. Electrical connection versions F1345 F1345 has different electrical connection versions depending on when the heat pump was manufactured. To check which electrical connection applies to your F1345, check the designation "2.0" visible above the right hand side of the terminal block as illustrated. Without thermostat, three active power steps 42 electric heater step active. Heat F1345 pump X3 5 6 7 8 9 1 2 3 4 5 6 With thermostat, three active power steps 42 immersion heater step active. 24 immersion heater step in emergency mode. X3 X3 5 6 7 8 9 1 2 3 4 5 6 X4 X4 1 2 3 Heat F1345 pump F1345 without 2.0 Terminal block in connects to the terminal blocks -X4 in the heat pump as illustrated. X3 X4 LEK 17

GB F1345 with 2.0 Terminal block on is connected to terminal blocks X5, X7 and X8 on the input board AA101 in the heat pump as illustrated. -FC1 -AA101 -AA101 -AA101 -X3 -X4 -X5 N 1 2 3 1 2 3 4 5 6 7 8 9 X5 X7 X8 -AA101 -X6 1 2 3 4 5 6 7 8 9 -AA101 -AA101 -AA101 -X7 -X8 - -AA101-0 1 2 3 4 1 2 3 1 2 3 1 2 3 4 5 Without thermostat, three active power steps 42 electric heater step active. 6 7 8 9 10 11 12131415 16171819 20 2122 X5 X5 X7 X7 2.0 1-AA32 3 4 5 6 1 2 3 4 -AA3 -AA3 -X6 1 2 3 4 5 6 7 8 9 10 11 12131415 16 17 18-2 -3 -AA3 2-0 -1 1 3 123 L N L L L N N N L N L N QN10 GP16 C K1 K2 K3 C NO NC K4 C NO NC -AA3-X7 A B A B 12V A B 0-10V 13 14 -GP16 -BE1 -BE2 -BE3 AUX 4 Heat F1345 pump 2.0 AUX 5 -BT1 -BT50 -BT25 -BT6 AUX 1 AUX 2 AUX 3 -BT7 -BT71 -EP14 -EP15 -BF1 With thermostat, three active power steps 42 immersion heater step active. 24 immersion heater step in emergency mode. X5 X7 X8 X5 X7 X8 1 2 3 4 5 6 1 2 3 4 1 2 3 Heat F1345 pump 2.0 18

GB SMO 20 and SMO 40 Terminal block in connects to the terminal blocks and AA7- in the control module as illustrated. - 123456 F1145, F1155, F1255 and VVM 500 For connection of to the above products an accessory is required. See the General section on page 13 to see which accessory is required for your climate unit. Terminal block in connects to terminal block and 0 on the accessory board as illustrated. LEK 1 2 3 4 5 6 - AA7-0 1 2 3 4 5 0 Accessory Tillbehörskort card 2 6 7 8 9 L N 1 1 0 2 3 4 Without thermostat, three active power steps 42 electric heater step active. AA7- AA7: 1 2 3 4 5 6 1 0 2 3 4 Control SMO module With thermostat, three active power steps 42 immersion heater step active. 24 immersion heater step in emergency mode. AA7- AA7: 1 2 3 4 5 6 1 0 2 3 4 Control SMO module 19

GB Activating The menu setting of can be performed via the start guide or directly in the menu system. Caution Start guide Also see the Installer manual for the product that will be connected to. The start guide appears upon first start-up after heat pump installation, but is also found in menu 5.7. Menu system F1345, SMO 20 and SMO 40 Menu 4.9.3 - degree minute setting Select when the addition is to start. Menu 5.1.12 - addition Setting: Max. number of permitted additional steps If binary stepping is to be used. F1145, F1155, F1255 and VVM 500 Information about menu settings for the products above is in the manuals for AXC 40 and DEH 500. See the General section on page13 to see which accessory is required for your product. 20

GB Technical data Dimensions All dimensions in mm. 400 350 75 100 85 210 350 700 21

GB Technical specifications IP 44 Electrical data Rated voltage Output immersion heater Immersion heater fuse Enclosure class Heating medium circuit Max permitted pressure in the boiler Min flow Max flow Dimensions and weight Width Depth Height Weight Volume Miscellaneous Material immersion heater Material tube Part No. V A MPa/bar l/h l/h mm mm mm kg litre 3 x 400 V ~ 50 Hz 42 63 IP44 0,7/7 1800 5400 350 400 700 30 4,5 SIS 2333 EN 1.4301 SIS 2333 EN 1.4301 067 075 Energy labelling Information sheet Supplier Model NIBE Energy efficiency class for space heating Rated heat output (Pdesign) Seasonal space heating energy efficiency Sound power level L WA indoors % db D 42 36,9 35 22

GB Technical documentation Model Condensing boiler Low-temperature boiler B11 boiler Cogeneration space heater Combination heater Applied standards Rated heat output Prated For boiler space heaters and boiler combination heaters: Useful heat output At rated heat output and high-temperature regime At 30 % of rated heat output and low-temperature regime P 4 P 1 Yes Yes Yes Yes Yes 42 42 No No No No No Seasonal space heating energy efficiency ƞ s 36,9 % For boiler space heaters and boiler combination heaters: Useful efficiency At rated heat output and high-temperature regime At 30 % of rated heat output and low-temperature regime ƞ 4 ƞ 1 40 % % Auxiliary electricity consumption At full load At part load Standby mode elmax elmin P SB 0,01 Other items Standby heat loss Ignition burner power consumption Annual energy consumption Sound power level, indoors P stby P ign Q HE L WA 0,2 35 h db For combination heaters Declared load profile for water heating Daily energy consumption Annual energy consumption Q elec AEC h h Water heating energy efficiency Daily fuel consumption Annual fuel consumption ƞ wh Q fuel AFC % h GJ 23

LEK DE Deutsch, IHB - Allgemeines ist eine Elektroheizpatrone, die einen Beitrag zur Wärmekapazität Ihrer NIBE-Klimaanlage leisten kann. Wenn der Heizbedarf die Kapazität der Klimaanlage übersteigt, wird die Elektroheizpatrone automatisch eingeschaltet. Die elektrische Ausrüstung ist an die Funktion der Klimaanlage angepasst. Die Elektroheizpatrone ist im Prinzip eine Heizpatrone, die in einem Wasserbehälter montiert ist oder ein Elektroheizkessel ohne Brauchwasserspeicher. Die elektrischen Edelstahl-Rohrwärmetauscher und das Elektroheizkesselrohr sind aus säurebeständigem Stahl (SIS 2333) gefertigt, wodurch eine sehr hohe Lebensdauer erreicht wird. Ein geringes Wasservolumen und eine gut isolierte Elektroheizpatrone bewirken extrem niedrige Wärmeverluste bei. Kompatible Produkte Je nach Produkt, mit dem verwendet werden soll, erfolgt der Anschluss auf unterschiedliche Weise. Diese Produkte können direkt mit verbunden werden: F1345 SMO 20 SMO 40 Aufstellung Die Elektroheizpatrone ist stehend zu montieren (siehe Abbildung unten). Zu Servicezwecken wird vor der Elektroheizpatrone ein Freiraum von 500 mm benötigt. Ist dies nicht möglich, sind demontierbare Kupplungen einzusetzen. Diese Produkte erfordern das Zubehör AXC 40: F1145 F1155 F1255 VVM 500 erfordert das Zubehör DEH 500. Inhalt 1 St. Elektroheizkassette 24

DE Position der Komponenten Komponentenverzeichnis EB1, EB20 FA1 FD1, FD4 QA1 Heizpatrone Sicherungsautomat Überhitzungsschutz Anschlussklemme, Eingang Anschlussklemme Schütz 6,0 (-K1) FD1 FD4 RF1 FA1 QA1 QM60 BT30 QM61 X EB1 QA2 QA3 QA41 Schütz 12,0 (-K2) Schütz 24,0 (-K3) Schütz, Überhitzungsschutz (-K4) QA2 QA3 QA41 EB20 X QA42 Schütz, Überhitzungsschutz (-K5) QA42 UB1 BT30 RF1 X Notbetriebsthermostat Entstörkondensator Anschluss Vorlauf, G 40 LEK UB2 PF1 X Anschluss Rücklauf, G 40 UB1, UB2 Kabeldurchführung QM60, QM61 Entlüftung PF1 Datenschild 25

DE Rohranschluss/Durchflussmesser Allgemeines Die Rohrinstallation muss gemäß den geltenden Standards vorgenommen werden. Per Umwälzpumpe ist der Volumenstrom an der Elektroheizpatrone zu gewährleisten. Wenn die Ventile des Heizsystems die Zirkulation komplett schließen können, muss ein Bypassventil installiert werden, damit ein konstanter Volumenstrom an der Elektroheizpatrone sichergestellt werden kann. Bei einer geschlossenen Anlage muss ein zugelassenes Sicherheitsventil sowie ein Druckausdehnungsgefäß installiert werden. ACHTUNG! Siehe auch das Installateurhandbuch für Ihre Wärmepumpe bzw. Inneneinheit. HINWEIS! Entleerung Das Rohrsystem muss durchgespült worden sein, bevor die Elektroheizpatrone angeschlossen wird, damit die enthaltenen Komponenten nicht durch Verunreinigungen beschädigt werden. Das System lässt sich am einfachsten leeren, indem am tiefsten Punkt der Rohrinstallation ein Entleerungsventil angebracht wird. Verbleibendes Wasser in wird über den Rücklaufanschluss (X) entleert, siehe "Position der Komponenten" auf Seite 25. Wird der Rücklaufanschluss an normalerweise für eine Entleerung der Anlage genutzt, empfiehlt sich hier die Montage eines Entleerungsventils. Druckverlustdiagramm 9 kpa 8 7 6 5 4 3 2 1 0 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Fluss l/h 26

DE Systemprinzip TIP! Siehe www.nibe.se/dockning für vollständige Dockungsprinzipien. Erklärung EB1 CM4 F QM40 - QM41 RN11 GP10 RM5 BT25 BT71 Elektroheizpatrone Ausdehnungsgefäß Sicherheitsventil Absperrventile Regelventil Umwälzpumpe Rückschlagventil Vorlauffühler Rücklauffühler Bezeichnungen der Komponentenpositionen gemäß Standard IEC 81346-1 und 81346-2. Systemprinzip -F -CM4 -EB1 -QM40 -QM41 -RN11 -RM5 -BT25 -BT71 -GP10 Värmepump/ Wärmepumpe/ Inneneinheit Inomhusmodul HINWEIS! Dies ist eine Prinzipskizze. Die tatsächliche Anlage muss gemäß den geltenden Normen geplant und montiert werden. 27

DE Elektrischer Anschluss HINWEIS! Alle elektrischen Anschlüsse müssen von einem geprüften Elektriker ausgeführt werden. Bei der Elektroinstallation und beim Verlegen der Leitungen sind die geltenden Vorschriften zu berücksichtigen. Das Klimatisierungssystem darf bei der Installation von nicht mit Spannung versorgt werden. muss über einen allpoligen Betriebsschalter mit mindestens 3 mm Schaltkontaktabstand installiert werden. umfasst einen Überhitzungsschutz sowie Schütze zur externen Regelung der drei Leistungsstufen 6, 12 und 24. Für eine optimale Funktionsweise sollte eine binäre Leistungssteuerung erfolgen, also mit 6, 12, 18, 24, 30, 36 und 42. Der Schaltplan befindet sich am Ende dieses Installateurhandbuchs. Elektroanschlussversionen F1345 F1345 verfügt je nach Herstellungsort der Wärmepumpe über verschiedene elektrische Anschlüsse. Um den jeweiligen elektrischen Anschluss für Ihre F1345 zu ermitteln, kontrollieren Sie, ob sich die Bezeichnung 2.0" rechts über den Anschlussklemmen befindet, siehe Abbildung. Ohne Thermostat, drei aktive elektrische Leistungsstufen Elektroheizpatronenstufe mit 42 aktiv Wärmepumpe F1345 X3 5 6 7 8 9 1 2 3 4 5 6 Mit Thermostat, drei aktive elektrische Leistungsstufen Elektroheizpatronenstufe mit 42 aktiv. Elektroheizpatronenstufe mit 24 im Reservebetrieb. X3 X3 5 6 7 8 9 1 2 3 4 5 6 X4 X4 1 2 3 Wärmepumpe F1345 F1345 ohne 2.0 Anschlussklemme in wird mit den Anschlussklemmen -X4 in der Wärmepumpe verbunden, siehe Abbildung. X3 X4 28 LEK

DE F1345 mit 2.0 Anschlussklemme in wird mit den Anschlussklemmen X5, X7 und X8 an der Eingangsplatine AA101 in der Wärmepumpe verbunden, siehe Abbildung. -FC1 -AA101 -AA101 -AA101 -X3 -X4 -X5 N 1 2 3 1 2 3 4 5 6 7 8 9 X5 X7 X8 -AA101 -X6 1 2 3 4 5 6 7 8 9 -AA101 -AA101 -AA101 -X7 -X8 - -AA101-0 1 2 3 4 1 2 3 1 2 3 1 2 3 4 5 Ohne Thermostat, drei aktive elektrische Leistungsstufen Elektroheizpatronenstufe mit 42 aktiv 6 7 8 9 10 11 12131415 16171819 20 2122 X5 X5 X7 X7 2.0 -AA3 -AA3 -AA3 -X6 1 2 3 4 5 6 7 8 9 10 11 12131415 16 17 18-2 -3 -AA3 2 1 2 3 4 5 6 1 2 3 4-0 -1 1 3 123 L N L L L N N N L N L N QN10 GP16 C K1 K2 K3 C NO NC K4 C NO NC -AA3-X7 A B A B 12V A B 0-10V 13 14 -GP16 -BE1 -BE2 -BE3 AUX 4 AUX 5 -BT1 -BT50 -BT25 -BT6 AUX 1 AUX 2 AUX 3 -BT7 -BT71 -EP14 -EP15 -BF1 Wärmepumpe F1345 2.0 Mit Thermostat, drei aktive elektrische Leistungsstufen Elektroheizpatronenstufe mit 42 aktiv. Elektroheizpatronenstufe mit 24 im Reservebetrieb. X5 X7 X8 X5 X7 X8 1 2 3 4 5 6 1 2 3 4 1 2 3 Wärmepumpe F1345 2.0 29

DE SMO 20 und SMO 40 Anschlussklemme in wird mit den Anschlussklemmen und AA7- im Steuermodul verbunden, siehe Abbildung. Mit Thermostat, drei aktive elektrische Leistungsstufen Elektroheizpatronenstufe mit 42 aktiv. Elektroheizpatronenstufe mit 24 im Reservebetrieb. AA7- AA7: - 123456 1 2 3 4 5 6-1 2 3 4 5 6 1 0 2 3 4 LEK AA7- Steuermodul SMO L N 1 1 0 2 3 4 Ohne Thermostat, drei aktive elektrische Leistungsstufen Elektroheizpatronenstufe mit 42 aktiv AA7- AA7: F1145, F1155, F1255 und VVM 500 Für den Anschluss von an die o.g. Produkte ist ein Zubehör erforderlich. Siehe Abschnitt "Allgemeines" auf Seite 24 für erforderliches Zubehör für Ihre Klimaanlage. Anschlussklemme in wird mit Anschlussklemme und 0 an der Zubehörplatine verbunden, siehe Abbildung. 1 2 3 4 5 6 1 0 2 3 4 0 1 2 3 4 5 0 2 6 7 8 9 Steuermodul SMO Zubehörplatine Tillbehörskort 30

DE Aktivierung von Die Menüeinstellung von kann per Startassistent oder direkt im Menüsystem vorgenommen werden. ACHTUNG! Siehe auch Installateurhandbuch für das Produkt, mit dem verbunden werden soll. Startassistent Der Startassistent erscheint bei der ersten Inbetriebnahme nach der Wärmepumpeninstallation. Er kann ebenfalls über Menü 5.7 aufgerufen werden. Menüsystem F1345, SMO 20 und SMO 40 Menü 4.9.3-Gradminuteneinstellung Hier legen Sie fest, wann die Zusatzheizung starten soll. Menü 5.1.12-ZH Einstellung von: Maximale Anzahl zulässiger Zusatzheizungsstufen. Wenn eine binäre Schaltung verwendet werden soll. F1145, F1155, F1255 und VVM 500 Informationen zu den Menüeinstellungen für die oben aufgeführten Produkte sind in den Handbüchern für AXC 40 und DEH 500 enthalten. Siehe Abschnitt "Allgemeines" auf Seite 24 für erforderliches Zubehör für Ihr Produkt. 31

DE Technische Daten Maße Alle Maße sind in mm angegeben. 400 350 75 100 85 210 350 700 32

DE Technische Daten IP 44 Elektrische Daten Nennspannung Heizpatronenleistung Absicherung Elektroheizpatrone Schutzklasse Heizkreis Max. zulässiger Druck im Kessel Min. Volumenstrom Max. Volumenstrom Abmessungen und Gewicht Breite Tiefe Höhe Gewicht Volumen Sonstiges Material Heizpatrone Material Rohr Art.nr. V A MPa/Bar) l/h l/h mm mm mm kg l 3 x 400 V ~ 50 Hz 42 63 IP44 0,7/7 1800 5400 350 400 700 30 4,5 SIS 2333 EN 1.4301 SIS 2333 EN 1.4301 067 075 Wärmemengenzählung Informationsblatt Hersteller Modell NIBE Effizienzklasse Raumerwärmung Nennheizleistung (Pdesign) Mittlerer Saisonwirkungsgrad Raumerwärmung Schallleistungspegel L WA im Innenbereich % db D 42 36,9 35 33

DE Technische Dokumentation Modell Kondensierender Heizkessel Niedrigtemperatur-Heizkessel Heizkessel vom Typ B11 Elektroheizkessel Heizkessel mit integrierter Brauchwarmwasserbereitung Geltende Normen Abgegebene Nennheizleistung Prated Ja Ja Ja Ja Ja 42 Nein Nein Nein Nein Nein Für Heizkessel für die zentrale Raumerwärmung und Heizkessel mit integrierter Brauchwarmwasserbereitung: Nutzbar gemachte abgegebene Wärme Bei abgegebener Nennheizleistung und Hochtemperaturbetrieb Bei 30% der abgegebenen Nennheizleistung und Niedrigtemperaturbetrieb P 4 P 1 42 Mittlerer Saisonwirkungsgrad für Raumerwärmung ƞ s 36,9 Für Heizkessel für die zentrale Raumerwärmung und Heizkessel mit integrierter Brauchwarmwasserbereitung: Nutzwirkungsgrad Bei abgegebener Nennheizleistung und Hochtemperaturbetrieb Bei 30% der abgegebenen Nennheizleistung und Niedrigtemperaturbetrieb ƞ 4 ƞ 1 40 % % % Stromverbrauch Zusatzheizung Bei Volllast Bei Teillast Standby-Modus elmax elmin P SB 0,01 Sonstige Posten Warmhalteverlust Energieverbrauch des Zündbrenners Jahresenergieverbrauch Schallleistungspegel, Innenbereich P stby P ign Q HE L WA 0,2 35 h db Für Heizkessel mit integrierter Brauchwarmwasserbereitung Deklariertes Verbrauchsprofil Brauchwasserbereitung Täglicher Energieverbrauch Jahresenergieverbrauch Q elec AEC h h Energieeffizienz Brauchwasserbereitung Tagesbrennstoffverbrauch Jahresbrennstoffverbrauch ƞ wh Q fuel AFC % h GJ 34

LEK Suomi, IHB - FI Yleistä on sähkövastus, jota voidaan käyttää NIBE-lämmitysjärjestelmän lämmitystehon täydennyksenä. Kun lämmöntarve on suurempi kuin lämmitysjärjestelmän kapasiteetti, sähkövastus kytketään automaattisesti. Sähkölaitteisto on sovitettu lämmitysjärjestelmän toimintaan. Sähkövastus on periaatteessa vesisäiliöön asennettu sähkövastus tai sähkökattila ilman lämminvesivaraajaa. Ruostumattomat vastukset ja putki on valmistettu haponkestävästä teräksestä (SIS 2333), jonka ansiosta laite on erittäin pitkäikäinen. :n pieni vesitilavuus ja hyvin eristetty sähkövastus takaavat pienet lämpöhäviöt. Asennus Sähkövastus asennetaan pystyasentoon (katso kuva alla). Jätä sähkövastuksen eteen 500 mm vapaata tilaa huoltoa varten. Jos tämä ei ole mahdollista, tulee käyttää irrotettavia liittimiä. Yhteensopivat tuotteet Liitäntätapa riippuu siitä, mihin tuotteeseen liitetään. Nämä tuotteet voidaan kytkeä suoraan :een: F1345 SMO 20 SMO 40 Nämä tuotteet vaativat lisävarusteen AXC 40: F1145 F1155 F1255 VVM 500 vaatii lisävarusteen DEH 500. Sisältö 1 kpl Sähkövastus 35

FI Komponenttien sijainti Komponenttiluettelo EB1, EB20 FA1 FD1, FD4 QA1 Sähkövastus Automaattivaroke Ylikuumenemissuoja Liitinrima, virransyöttö Liitinrima Kontaktori 6,0 (-K1) FD1 FD4 RF1 FA1 QA1 QM60 BT30 QM61 X EB1 QA2 QA3 QA41 Kontaktori 12,0 (-K2) Kontaktori 24,0 (-K3) Kontaktori, ylikuumenemissuoja (-K4) QA2 QA3 QA41 EB20 X QA42 Kontaktori, ylikuumenemissuoja (-K5) QA42 UB1 BT30 RF1 X Varatilatermostaatti Häiriönpoistokondensaattori Liitäntä, menojohto, G 40 LEK UB2 PF1 X Liitäntä, paluujohto, G 40 UB1, UB2 Kaapeliläpivienti QM60, QM61 Ilmanpoisto PF1 Tyyppikilpi 36

FI Putkiliitäntä Yleistä Putkiasennukset on tehtävä voimassa olevien määräysten mukaisesti. Järjestelmään on asennettava kiertovesipumppu, joka varmistaa virtauksen sähkökattilan yli. Jos lämmitysjärjestelmän venttiilit voivat katkaista kierron kokonaan, järjestelmään on asennettava ohivirtausventtiili, jotta virtaus sähkökattilan yli ei katkea. Suljettu järjestelmä on varustettava hyväksytyllä varoventtiilillä ja paisuntasäiliöllä. MUISTA! Katso myös lämpöpumpun/sisäyksikön asennusohje. Tyhjennys HUOM! Putkisto on huuhdeltava ennen sähkökattilan asennusta epäpuhtauksien aiheuttamien vahinkojen välttämiseksi. Järjestelmä on helpoin tyhjentää asentamalla tyhjennysventtiili putkiston alimpaan pisteeseen. :n jäljelle jäänyt vesi tyhjennetään paluuliitännän (X) kautta, katso "Komponenttien sijainti" sivulla 36. Jos järjestelmä tyhjennetään tavallisesti :n paluuliitännän kautta, siihen kannattaa asentaa tyhjennysventtiili. Painehäviökäyrä 9 kpa 8 7 6 5 4 3 2 1 0 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Virtaus l/h 37

FI Järjestelmäperiaate VIHJE! Katso liitäntävaihtoehdot osoitteessa www.nibe.se/dockning. Selvitys EB1 CM4 F QM40 - QM41 RN11 GP10 RM5 BT25 BT71 Sähkövastus Kalvopaisuntasäiliö Varoventtiili Sulkuventtiilit Säätöventtiili Kiertovesipumppu Takaiskuventtiili Menolämpötila-anturi Paluulämpötila-anturi Komponenttikaavion merkinnät standardin IEC 81346-1 ja 81346-2 mukaan. Järjestelmäperiaate -F -CM4 -EB1 -QM40 -QM41 -RN11 -RM5 -BT25 -BT71 -GP10 Värmepump/ Lämpöpumppu/ sisäyksikkö Inomhusmodul HUOM! Tämä on periaatekaavio. Laitteisto on suunniteltava voimassa olevien normien mukaisesti. 38

FI Sähköasennukset HUOM! Sähköasennukset saa tehdä vain valtuutettu sähköasentaja. Sähköasennukset ja johtimien veto on tehtävä voimassa olevien määräysten mukaisesti. Lämmitysjärjestelmän pitää olla jännitteetön :n asennuksen aikana. kytketään kaikkinapaiseen turvakytkimeen, jonka kosketinväli on vähintään 3 mm. :ssa on ylikuumenemissuoja sekä kontaktorit kolmen tehoportaan, 6, 12 ja 24, ohjaamiseen. Parhaan toiminnan varmistamiseksi tehoa tulisi ohjata binäärisesti, ts. 6, 12, 18, 24, 30, 36 ja 42. Kytkentäkaavio on tämän asennusohjeen lopussa. Sähkökytkentäversiot F1345 F1345:n sähköliitännät riippuvat lämpöpumpun valmistuspaikasta. Nähdäksesi oman F1345-lämpöpumppusi liitännät tarkasta onko liittimien yläpuolella oikealla puolella kuvan mukainen merkintä "2.0". Ilman termostaattia, kolme aktiivista sähköporrasta 42 sähkövastusporras aktiivinen. Lämpöpumppu F1345 X3 5 6 7 8 9 1 2 3 4 5 6 Termostaatilla, kolme aktiivista sähköporrasta 42 sähkövastusporras aktiivinen. 24 sähkövastusporras varatilassa. X3 X3 5 6 7 8 9 1 2 3 4 5 6 X4 X4 1 2 3 Lämpöpumppu F1345 F1345 ilman 2.0 Liitin :ssa kytketään lämpöpumpun liittimiin -X4 kuvan mukaisesti. X3 X4 LEK 39

FI F1345 ja 2.0 Liitin :ssa kytketään lämpöpumpun tulokortin AA101 liittimiin X5, X7 ja X8 kuvan mukaisesti. -FC1 -AA101 -AA101 -AA101 -X3 -X4 -X5 N 1 2 3 1 2 3 4 5 6 7 8 9 X5 X7 X8 -AA101 -X6 1 2 3 4 5 6 7 8 9 L N L L L N N N L N L N QN10 GP16 -AA101 -AA101 -AA101 -X7 -X8 - -AA101-0 1 2 3 4 1 2 3 1 2 3 1 2 3 4 5 C K1 K2 K3 C NO NC K4 C NO NC -AA3-X7 A B A B 6 7 8 9 10 11 12131415 16171819 20 2122 12V Ilman termostaattia, kolme aktiivista sähköporrasta A B 0-10V 13 14 42 sähkövastusporras aktiivinen. -GP16 -BE1 -BE2 -BE3 AUX 4 AUX 5 -AA3 -X6 1 2 3 4 5 6 7 8 9 10 11 12131415 -BT1 -BT50 X5 X5 -BT25 -BT6 AUX 1 AUX 2 AUX 3 X7 -BT7 X7 16 17 18 1 2 3 4 5 6 1 2 3 4 -BT71 2.0 -AA3 -AA3-2 -3 -AA3 2-0 -1 1 3 123 -EP14 -EP15 -BF1 Lämpöpumppu F1345 2.0 Termostaatilla, kolme aktiivista sähköporrasta 42 sähkövastusporras aktiivinen. 24 sähkövastusporras varatilassa. X5 X7 X8 X5 X7 X8 1 2 3 4 5 6 1 2 3 4 1 2 3 Lämpöpumppu F1345 2.0 40

FI SMO 20 ja SMO 40 Liitin :ssa kytketään ohjausyksikön liittimiin ja AA7- kuvan mukaisesti. - 123456 F1145, F1155, F1255 ja VVM 500 :n kytkentään yllä mainittuihin tuotteisiin vaaditaan lisävaruste. Katso luvusta "Yleistä" sivulla 35 lämmitysjärjestelmään tarvittavat lisävarusteet. Liitin :ssa kytketään lisävarustekortin liittimiin ja 0 kuvan mukaisesti. - 1 2 3 4 5 6 AA7-0 1 2 3 4 5 0 2 6 7 8 9 LEK Lisävarustekortti Tillbehörskort L N 1 1 0 2 3 4 Ilman termostaattia, kolme aktiivista sähköporrasta 42 sähkövastusporras aktiivinen. AA7- AA7: 1 2 3 4 5 6 1 0 2 3 4 Ohjausyksikkö SMO Termostaatilla, kolme aktiivista sähköporrasta 42 sähkövastusporras aktiivinen. 24 sähkövastusporras varatilassa. AA7- AA7: 1 2 3 4 5 6 1 0 2 3 4 Ohjausyksikkö SMO 41

FI :n aktivointi :n asetukset voidaan tehdä aloitusoppaan kautta tai suoraan valikkojärjestelmässä. MUISTA! Katso myös :een liitettävän tuotteen asennusohje. Aloitusopas Aloitusopas näytetään ensimmäisen käynnistyksen yhteydessä lämpöpumpun asennuksen jälkeen, mutta se löytyy myös valikosta 5.7. Valikkojärjestelmä F1345, SMO 20 ja SMO 40 Valikko 4.9.3 - asteminuuttiasetukset Tässä valitset milloin lisälämmönlähteen tulee käynnistyä. Valikko 5.1.12 - lisälämpö Asetus: Lisälämpöportaiden enimmäismäärä. Jos binääristä porrastusta halutaan käyttää. F1145, F1155, F1255 ja VVM 500 Yllä mainittujen tuotteiden valikkoasetukset on selostettu AXC 40:n ja DEH 500:n käyttöohjeissa. Katso luvusta "Yleistä" sivulla 35 tuotetta varten tarvittavat lisävarusteet. 42

FI Tekniset tiedot Mitat Kaikki mitat ovat millimetreinä. 400 350 75 100 85 210 350 700 43

FI Tekniset tiedot IP 44 Sähkötiedot Nimellisjännite Teho, sähkövastus Varoke, sähkövastus Kotelointiluokka Lämminvesipiiri Kattilan suurin sallittu paine Minimivirtaus Suurin virtaama Mitat ja painot Leveys Syvyys Korkeus Paino Tilavuus Muut Materiaali, sähkövastus Materiaali, putki Tuotenumero V A MPa/bar l/h l/h mm mm mm kg litraa 3 x 400 V ~ 50 Hz 42 63 IP44 0,7/7 1800 5400 350 400 700 30 4,5 SIS 2333 EN 1.4301 SIS 2333 EN 1.4301 067 075 Energiamerkintä Infosivu Valmistaja Malli NIBE Huonelämmityksen tehokkuusluokka Nimellinen lämmitysteho (Pdesign) Huonelämmityksen kausikeskihyötysuhde Äänitehotaso L WA sisällä % db D 42 36,9 35 44

FI Tekninen dokumentaatio Malli Kondensoiva kattila Matalalämpötilakattila Kattila tyyppiä B11 Sähkölämpökattila Kattila sisäänrakennetulla käyttövesilämmityksellä Sovellettavat standardit Nimellinen antolämmitysteho Prated Kyllä Kyllä Kyllä Kyllä Kyllä Kattiloille keskuslämmityksellä ja kattiloille sisäänrakennetulla käyttövesilämmityksellä: Hyödynnetty luovutettu lämpö Nimellisellä antolämmitysteholla ja korkealämpötilakäytössä 30 %:lla nimellisestä antolämmitystehosta ja matalalämpötilakäytössä P 4 P 1 42 42 Ei Ei Ei Ei Ei Huonelämmityksen kausikeskihyötysuhde. ƞ s 36,9 % Kattiloille keskuslämmityksellä ja kattiloille sisäänrakennetulla käyttövesilämmityksellä: nettohyötysuhde Nimellisellä antolämmitysteholla ja korkealämpötilakäytössä 30 %:lla nimellisestä antolämmitystehosta ja matalalämpötilakäytössä ƞ 4 ƞ 1 40 % % Lisälämmönlähteen sähkönkulutus Täydellä kuormalla Osakuormituksella Valmiustila elmax elmin P SB 0,01 Muut tiedot Lämpimänäpitohäviö Polttimen energiankulutus Vuotuinen energiankulutus Äänen tehotaso, sisällä P stby P ign Q HE L WA 0,2 35 h db Kattiloille sisäänrakennetulla käyttövesilämmityksellä Ilmoitettu laskuprofiili käyttöveden lämmityksessä Päivittäinen energiankulutus Vuotuinen energiankulutus Q elec AEC h h Käyttövesilämmityksen energiatehokkuus Päivittäinen polttoaineenkulutus Vuotuinen polttoaineenkulutus ƞ wh Q fuel AFC % h GJ 45

46 Elschema/Wiring diagram/elektrischer schaltplan/elektrisch schema

WS name: -Gemensamt WS version: a49 (working edition) Publish date: 2015-07-10 11:53 NIBE AB Sweden Hannabadsvägen 5 Box 14 SE-285 21 Markaryd info@nibe.se www.nibe.eu 331550