Estimated Energy Consumption of the Finnish Building Stock Using Representative Building Types



Samankaltaiset tiedostot
Defining nearly zero in Finland - FInZEB

Renewable energy production of Finnish heat pumps. Final report of the SPF-project

Efficiency change over time

Laskentaoletukset ja laskentamenetelmien kehitystarpeet

Vuoden 2012 energiamääräysten mukainen perinnetalo. Avanto arkkitehdit

Capacity Utilization

Vuoden 2012 energiamääräysten mukainen perinnetalo. Arkkitehtitoimisto A-konsultit Oy

Smart City -ratkaisut

TEST REPORT Nro VTT-S Air tightness and strength tests for Furanflex exhaust air ducts

Other approaches to restrict multipliers

PIENTALOJEN VUOTOILMANVAIHTUVUUDEN ARVIOINTIMENETELMÄ SUOMEN OLOSUHTEISIIN

Lapuan myöntämä EU tuki SOLUTION asuinalueille omakoti- tai rivitaloa rakentaville

TIEKE Verkottaja Service Tools for electronic data interchange utilizers. Heikki Laaksamo

ELEMET- MOCASTRO. Effect of grain size on A 3 temperatures in C-Mn and low alloyed steels - Gleeble tests and predictions. Period

16. Allocation Models

National Building Code of Finland, Part D1, Building Water Supply and Sewerage Systems, Regulations and guidelines 2007

Kansainvälisiä tutkimus- ja kehitysprojekteja ekotehokkaan rakennetun ympäristön tuottamiseen, käyttöön ja ylläpitoon

The CCR Model and Production Correspondence

ReFuel 70 % Emission Reduction Using Renewable High Cetane Number Paraffinic Diesel Fuel. Kalle Lehto, Aalto-yliopisto 5.5.

WAMS 2010,Ylivieska Monitoring service of energy efficiency in housing Jan Nyman,

Land-Use Model for the Helsinki Metropolitan Area

Suomen Aurinkolämpö Oy

Lämmitysjärjestelmät

RAKENNUSTEN ENERGIANKÄYTÖN OPTIMOINTI. Kai Sirén Aalto yliopisto

LX 70. Ominaisuuksien mittaustulokset 1-kerroksinen 2-kerroksinen. Fyysiset ominaisuudet, nimellisarvot. Kalvon ominaisuudet

S Sähkön jakelu ja markkinat S Electricity Distribution and Markets

Tynnyrivaara, OX2 Tuulivoimahanke. ( Layout 9 x N131 x HH145. Rakennukset Asuinrakennus Lomarakennus 9 x N131 x HH145 Varjostus 1 h/a 8 h/a 20 h/a

60- ja 70-luvun kerrostalojen energiavirtoja

Metsälamminkankaan tuulivoimapuiston osayleiskaava

Sähköntuotanto energialähteittäin Power generation by energy source

TM ETRS-TM35FIN-ETRS89 WTG

NAO- ja ENO-osaamisohjelmien loppuunsaattaminen ajatuksia ja visioita

FIGBC, VIHREÄ FOORUMI, KÄYTÖSSÄ OLEVIEN KIINTEISTÖJEN SERTIFIOINTIEN PARHAAT KÄYTÄNNÖT, BREEAM IN-USE

Vuoden 2012 energiamääräysten mukainen perinnetalo. Kirsti Sivén & Asko Takala Arkkitehdit Oy

Rakentamisen näkymät EU-alueella ja Suomessa

( ( OX2 Perkkiö. Rakennuskanta. Varjostus. 9 x N131 x HH145

Ihmisten yksilöllisten lämpöaistimusten. vaikutukset talotekniikan suunnitteluun. Evicures,

Asuinkerrostalojen energiaremontointi ja kustannusoptimaaliset päästövähennykset Janne Hirvonen Juha Jokisalo, Juhani Heljo, Risto Kosonen

TM ETRS-TM35FIN-ETRS89 WTG

3 9-VUOTIAIDEN LASTEN SUORIUTUMINEN BOSTONIN NIMENTÄTESTISTÄ

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

AYYE 9/ HOUSING POLICY

( ,5 1 1,5 2 km

TM ETRS-TM35FIN-ETRS89 WTG

Alternative DEA Models

WindPRO version joulu 2012 Printed/Page :42 / 1. SHADOW - Main Result

Sähköntuotanto energialähteittäin Power generation by energy source

Sähköntuotanto energialähteittäin Power generation by energy source

Sähköntuotanto energialähteittäin Power generation by energy source

TM ETRS-TM35FIN-ETRS89 WTG

Use of spatial data in the new production environment and in a data warehouse


,0 Yes ,0 120, ,8

Toimintamallit happamuuden ennakoimiseksi ja riskien hallitsemiseksi turvetuotantoalueilla (Sulfa II)

Jätehuollon vaikutusten arviointi CIRCWASTEalueilla ja edelläkävijäkunnissa

Infrastruktuurin asemoituminen kansalliseen ja kansainväliseen kenttään Outi Ala-Honkola Tiedeasiantuntija

TM ETRS-TM35FIN-ETRS89 WTG

Results on the new polydrug use questions in the Finnish TDI data

Tampere-Pirkkala airport Survey on noise

Metsäbiomassaan perustuvien nestemäisten biopolttoaineiden ilmastovaikutukset

2017/S Contract notice. Supplies

WindPRO version joulu 2012 Printed/Page :47 / 1. SHADOW - Main Result

MUSEOT KULTTUURIPALVELUINA

TM ETRS-TM35FIN-ETRS89 WTG

Sähköntuotanto energialähteittäin Power generation by energy source

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

SolarForum. An operation and business environment development project

Laskuri investointien avuksi

1. SIT. The handler and dog stop with the dog sitting at heel. When the dog is sitting, the handler cues the dog to heel forward.

nzeb ja RES vaatimusten tilanne muissa jäsenmaissa

Sähköntuotanto energialähteittäin Power generation by energy source

Sähköntuotanto energialähteittäin Power generation by energy source

Sähköntuotanto energialähteittäin Power generation by energy source

Kuvailulehti. Korkotuki, kannattavuus. Päivämäärä Tekijä(t) Rautiainen, Joonas. Julkaisun laji Opinnäytetyö. Julkaisun kieli Suomi

On instrument costs in decentralized macroeconomic decision making (Helsingin Kauppakorkeakoulun julkaisuja ; D-31)

Making use of BIM in energy management

HARJOITUS- PAKETTI A

LYTH-CONS CONSISTENCY TRANSMITTER

ASUNTOSUUNNITTELU TÄNÄÄN

Sähköntuotanto energialähteittäin Power generation by energy source

KONEISTUSKOKOONPANON TEKEMINEN NX10-YMPÄRISTÖSSÄ

Building Information Model (BIM) promoting safety in the construction site process. SafetyBIM research project 10/2007 2/2009. (TurvaBIM in Finnish)

Muut tieteelliset julkaisut

Tilausvahvistus. Anttolan Urheilijat HENNA-RIIKKA HAIKONEN KUMMANNIEMENTIE 5 B RAHULA. Anttolan Urheilijat

RAKLI KTI Barometer Survey. Autumn 2012

Research plan for masters thesis in forest sciences. The PELLETime 2009 Symposium Mervi Juntunen

Geoenergian tulevaisuuden visio. Jari Suominen

CO2-tavoitteet aluesuunnittelussa; Case Lontoo

Indoor Environment

Returns to Scale II. S ysteemianalyysin. Laboratorio. Esitelmä 8 Timo Salminen. Teknillinen korkeakoulu

Suomen 2011 osallistumiskriteerit

Suomen Ympäristökeskuksen Synergiatalo. P U U P Ä I V Ä S a m u l i M i e t t i n e n

FIS IMATRAN KYLPYLÄHIIHDOT Team captains meeting

TM ETRS-TM35FIN-ETRS89 WTG

Kaivostoiminnan eri vaiheiden kumulatiivisten vaikutusten huomioimisen kehittäminen suomalaisessa luonnonsuojelulainsäädännössä

Increase of opioid use in Finland when is there enough key indicator data to state a trend?

Stormwater filtration unit

Transkriptio:

Estimated Energy Consumption of the Finnish Building Stock Using Representative Building Types Riikka Holopainen Senior Scientist VTT Technical Research Centre of Finland, Finland Riikka.Holopainen@vtt.fi Pekka Tuominen, VTT Technical Research Centre of Finland, Finland, Pekka.Tuominen@vtt.fi Juha Jokisalo, Aalto University, Finland, Juha.Jokisalo@aalto.fi Lari Eskola, Aalto University, Finland, Lari.Eskola@aalto.fi Summary The energy consumption of different types in the stock was estimated using a twofold modelling approach. First representative s of various types and ages were modelled to establish their energy consumption using dynamic modelling. Then the cumulative energy consumption of these types was calculated based on the modelled development of the stock using the REMA model at VTT. According to the estimate produced by the calculation for the year 2012 the stock will consume 73000 GWh of energy (including electricity for ) and in 18600 GWh of electricity (excluding ). For 2020 a similar calculation suggests a consumption of 76900 GWh of energy and in 19900 GWh of electricity for the whole stock. The results fit reasonably well within the variation present in past calculations, with somewhat higher consumption in single-family homes than other studies have suggested. Keywords: Energy, Energy consumption, Building stock, Modelling 1. Introduction The objects of the Finnish SPF (Seasonal Performance Factor) project are to define a national seasonal performance factor calculation for heat pumps and to estimate the energy saving and renewable energy potential of heat pumps on the Finnish stock. The project duration is from 1.3.2011 to 31.12.2013 and the project is financed by the Finnish ministry of employment and the economy, the Finnish ministry of the environment and SITRA. This paper presents results from Task 2 Energy use of the Finnish stock, where the energy consumption of the Finnish stock was estimated using standard types (detached, apartment, office and summer cottage) for different decades. The energy consumption of different types in the stock was estimated using a twofold modelling approach. First representative s of various types and ages were modelled to establish their energy consumption using dynamic simulation tool IDA-ICE. Then the cumulative energy consumption of these types was calculated based on the modelled development of the stock using the REMA model at VTT. The results were compared with the national statistics [1] and previous estimates ([2], [3], [4]) and four rounds of iteration were completed resulting in calibrated types, a new estimate for the composition of energy consumption in the stock and a forecast for expected changes in energy consumption.

2. Methods Four model types where chosen to represent the major types that constitute the stock: detached s (about 38 % of the total floor area in the stock), apartment s (31 %), commercial and public s, represented by an office (26 %), and holiday homes (5 %). The model types are presented in Figures 1-3. The living area of the detached was 134 m 2, the living area of the apartment was 814 m 2, the net area of the office is 2 695 m 2 and the living area of the cottage was 134 m 2. Fig. 1 Model type for the singlefamily and the summer cottage Fig. 2 Model type for the apartment Fig. 3 Model type for the office The s were further divided into four age groups and individually modelled: s built before 1960 (subgroup A), between 1960 1979 (subgroup B), between 1980 2000 (subgroup C1), and between 2001 2010 (subgroup C2). The stock in the year 2010 is presented in Table 1. Future construction was modelled as norm s built according to 2010 regulation (subgroup D1), low-energy s (subgroup D2) and very low-energy s (subgroup D3). The airtightness of the envelope is presented in Table 1. For s with natural ventilation (*) the air-leakage through the envelope is included in the air-change rate. The heat loss values (U-values) of different structures are presented in Table 2. Table 1. Air-tightness of the envelope n50, 1/h Detached Cottage A * * * * B * 2.3 [5] 2.3 [5] * C1 4.0 [6] 1.0 1.5 7.9 [7] C2 3.5 [6] 0.9 [7] 0.9 [8] 5.8 [7] D1 2.0 0.7 0.5 5.8 [7] D2 0.8 0.6 0.5 0.8 D3 0.6 0.6 0.5 0.6 The detached is heated and ventilated constantly. The apartment is also constantly heated and ventilated, but in apartment s with mechanical exhaust ventilation system the ventilation rate is 50 % of the full rate during 18:00 7:00 and 9:00 16:00. s D1, D2 and D3 have a mechanical system in the case of detached s but not in the case of apartment s.

Table 2. Heat loss values of the buiding structures. OW = outer wall, UF = upper floor, BF = base floor, W = window A B C1 C2 D1 Detached OW 0.69 [10] UF 0.41[10] OW 0.42[10] UF 0.24[10] OW 0.28 UF 0.22 BF 0.36 W 1.6[10] OW 0.25 UF 0.16 BF 0.25 W 1.4 OW 0.17 UF 0.09 BF 0.16 W 1.0 OW 0.83[10] UF 0.42[10] OW 0.47[10] UF 0.29[10] OW 0.28 UF 0.22 BF 0.36 W 1.6[10] OW 0.25 UF 0.16 BF 0.25 W 1.4 OW 0.17 UF 0.09 BF 0.16 W 1.0 OW 0.83[a] UF 0.42[a] W 2.2[a] OW 0.47[a] UF 0.29[a] W 2.2[a] OW 0.28 UF 0.22 BF 0.36 W 1.6[a] OW 0.25 UF 0.16 BF 0.25 W 1.4 OW 0.17 UF 0.09 BF 0.16 W 1.0 D2 OW 0.14, UF 0.08, BF 0.12, W 0.9[11] D3 OW 0.08 UF 0.07 BF 0.09, W 0.7[12] Table 3. Set indoor temperatures Detached Cottage Cottage A 21.0 C [1] 22 C [2] 21.5 C 21.0 C B 21.0 C [1] 22 C [2] 21.5 C 21.0 C C1 21.0 C [1] 22 C [2] 21.5 C 21.0 C C2 21.0 C [1] 21.5 C [2] 21.5 C 21.0 C in subgroup A in subgroup A in subgroup B in subgroup C1 according to Finnish code, part C3 (2010), log wall U- value 0.4 in subgroup D2 in subgroup D3 D1, D2, D3 21.0 C [1] 21.0 C [3] 21.5 C 21.0 C [1] bathroom and sauna set temperatures 21 C, [2] cellar and staircase set temperatures 19.0 C, WC and bathroom set temperatures 23 C, [3] cellar and staircase set temperatures 17.0 C, WC and bathroom set temperatures 23 C. The office is heated continuously. In subgroups B and C1 the ventilation is on during week-days between 6:00 and 20:00. In subgroups C2, D1, D2 and D3 the ventilation is on during week-days between 6:00 and 20:00. In other times only the social spaces are ventilated with the ventilation rate of 0.15 dm³/s,m². s C1, C2, D1, D2 and D3 have a mechanical system operating during weekdays between 6:00 and 20:00. The recreational cottage is a private free-time home used annually an estimated typical length. Heating and ventilation is on during the usage time, outside the usage time there s a base load. The usage time is whole July, every weekend in June and August, and every third week-end from September to May. The indoor temperature set-values are presented in Table 3. The ventilation systems are presented in Table 4 and the ventilation rates in Table 5. The warm usage is presented in Table 6. The device electricity use of the different types was according to the Finnish Building Code, part D3 (2012).

Table 4. Ventilation systems. NV = natural ventilation, ME = mechanical exhaust ventilation, MSE = mechanical suppy and exhaust ventilation, HR = heat recovery (temperature efficiency ) Sub-group Detached A NV NV NV NV B NV ME ME NV C1 ME ME MSE + HR (50%) ME C2 MSE + HR (60%) MSE + HR (60%) MSE + HR (80%) ME Cottage D1 MSE + HR (60%) MSE + HR (60%) MSE + HR (80%) MSE + HR (60%) D2 MSE + HR (80%) MSE + HR (80%) MSE + HR (80%) MSE + HR (80%) D3 MSE + HR (85%) MSE + HR (85%) MSE + HR (85%) MSE + HR (80%) Table 5. Air-change rate, 1/h Detached Cottage A 0.41 [13] 0.62 [13] 0.62 [13] 0.41* B 0.41 [13] 0.43 [14] 0.43 [14] 0.41* C1 0.46 [13] 0.5 [15] 0.5 [15] 0.46* C2 0.40 [6] 0.56 [6] 0.5 [16] 0.40* D1 0.5 [17] 0.5 [17] 0.5 [17] 0.5* D2 0.5 [17] 0.5[17] 0.5 [17] 0.5* D3 0.5[17] 0.5[17] 0.5 [17] 0.5* * during usage time, in other times only air-leakage through the envelope. Table 6. consumption Detached, dm 3 /pers,day, dm 3 /pers,day, dm 3 /rm 2,a A 42 [18] 64 [19] 100 [20] B 42 [18] 62 [19] 100 [20] C1 42 [18] 59.2 [19] 100 [20] C2 42 [18] 57.6 [19] 100 [20] D1, D2, D3 42 [18] 56 [19] 100 [20] Cottage

3. Results The energy demands of the different standard types and subgroups were simulated using IDA ICE 4.2 dynamical simulation program with the test weather data 2012 of Jyväskylä, Central Finland (Kalamees 2012). The and energy use is presented in Table 8 for the detached, in Table 9 for the apartment, in Table 10 for the office and in Table 11 for the cottages. Table 8. Heating and energy net demands of the detached, kwh/m 2 A 242 0 0 21 B 189 0 0 21 C1 157 0 0 21 C2 98 0 10 21 D1 68 2 9 21 D2 53 3 2 21 D3 38 4 2 21 Table 9. Heating and energy net demands of the apartment, kwh/m 2 A 200 0 0 49 B 125 0 0 47 C1 51 0 0 45 C2 22 0 17 44 D1 11 0 15 43 D2 8 0 4 43 D3 4 0 3 43 Table 10. Heating and energy net demands of the office, kwh/m 2 A 232 0 0 6 B 135 0 0 6 C1 105 12 27 6 C2 52 20 5 6 D1 41 16 6 6 D2 33 23 6 6 D3 25 27 5 6 Table 11. Heating and energy net demands of the cottage, kwh/m 2 A 94 0 0 11 B 91 0 0 11 C1 63 0 0 11 C2 61 0 0 11 D1 39 0 1 11 D2 22 0 0 11 D3 17 0 0 11 The cumulative energy consumption of the whole stock was calculated based on the modelled development of the stock using the REMA model developed at VTT. The simulated energy demand results of each standard type and subgroup were used as an input for the REMA model to calculate the total energy consumption of the stock in each year, taking into consideration the estimated changes in the future development of the

Table 1. Modelled size of stock in 2010 according to the REMA model, in millions of m 2. Inconcistences in totals are due to rounding. Detached s s s Cottages A 50 19 24 10 B 40 51 30 6 C1 + C2 57 49 47 5 Total 147 119 100 21 stock According to the estimate produced by the calculation for the year 2012 singlefamily s will consume, in terms of delivered energy, 32600 GWh of energy (including electricity for ) and 5200 GWh of electricity (excluding ), multi-family s consume 23900 GWh in and 5600 GWh of electricity, commercial and public s 20000 GWh in and 7500 GWh of electricity and, finally, holiday homes 2800 GWh in 300 GWh of electricity, totalling in 73000 GWh of energy and in 18600 GWh of electricity for the whole stock. For 2020 a similar calculation suggests that single-family s will consume 31900 GWh of energy (including electricity for ) and 5600 GWh of electricity (excluding ), multi-family s consume 23200 GWh in and 5800 GWh of electricity, commercial and public s 19100 GWh in and 8100 GWh of electricity and, finally, holiday homes 2700 GWh in 400 GWh of electricity, totalling in 76900 GWh of energy and in 19900 GWh of electricity for the whole stock. 4. Conclusion Fig. 2 The results (Modelled estimate) compared to Statistics Finland [1], revised statistics [2], Ekorem project [3] and ERA project [4]. comfortable temperature. The numbers correspond to an increase of 5 % in energy consumption and 6 % increase in electricity consumption in the stock by the year 2020. This is in agreement with a slowing growth of energy consumption with a growing emphasis on electricity consumption. The results fit reasonably well within the variation present in past calculations, with somewhat higher consumption in single-family homes than other studies have suggested. This might be because a significant part of the singlefamily home stock might be underused or in disuse and thus kept in lower than A major benefit of the approach chosen here is that each type and subtype of s is individually modelled and therefore their contribution to the total energy consumption can be traced to the modelled physical characteristics of the s. This allows the study of individual modifications and their effects to energy consumption on a large scale.

5. References [1] STATISTICS FINLAND, Energiatilasto Vuosikirja 2010, Tilastokeskus, Helsinki, 2011. [2] STATISTICS FINLAND, Asumisen (kotitalouksien) energian kulutus -loppuraportti, Tilastokeskus, Helsinki, 2011. [3] HELJO J., NIPPALA E., NUUTILA H., Rakennusten energiankulutus ja CO2-ekv päästöt Suomessa, Tampere University of Technology, 2005. [4] VEHVILÄINEN I. ET AL., Rakennetun ympäristön energiankäyttö ja kasvihuonekaasupäästöt, Sitra, 2010. [5] POLVINEN M., KAUPPI A., SAARIMAA J., HAALAHTI., LAURIKAINEN, M., Rakennusten ulkovaipan ilmanpitävyys. VTT. Tutkimuksia 215. 1983. [6] VINHA, J., KORPI, M., KALAMEES, T., ESKOLA, L., PALONEN, J., KURNITSKI, J., VALOVIRTA, I., MIKKILÄ, A., JOKISALO, J., Puurunkoisten pientalojen kosteus- ja lämpötilaolosuhteet, ilmanvaihto ja ilmatiiviys. Tampere, Tampereen teknillinen yliopisto, Talonrakennustekniikan laboratorio, Tutkimusraportti 131. 102 s. + 10 liites. 2005. [7] VINHA, J., KORPI, M., KALAMEES, T., JOKISALO, J., ESKOLA, L., PALONEN, J., KURNITSKI, J., AHO, H., SALMINEN, M., SALMINEN, K., KETO, M., Asuinrakennusten ilmanpitävyys, sisäilmasto ja energiatalous. Tampere, Tampereen teknillinen yliopisto, Rakennustekniikan laitos, Rakennetekniikka, Tutkimusraportti 140. 2009. [8] SUOMELA M., Toimistotalon ilmatiiviyden mittaaminen. Seinäjoen ammattikorkeakoulu. Opinnäytetyö 96. 2010. [9] ESKOLA, L., KURNITSKI, J., PALONEN, J., Building leakage rate measurement with 's own air handling unit. Healthy Buildings 2009, Syracuse, NY, USA, 13-17 September 2009. 6 p. [10] NYKÄNEN, V. & HELJO, J., Rakennusten energiatalous Suomessa. Tampereen teknillinen korkeakoulu, rakentamistalous. Sarja d:83. Kauppa ja teollisuusministeriö, energiaosasto. Helsinki 1985 [11] Typical U-values for low energy s: http://northpass.vtt.fi/documents/northpass_d2_loccriteria.pdf [12] NIEMINEN J., JAHN J. JA AIRAKSINEN M., Passiivitalon rakennesuunnittelu. Promotion of European Passive Houses. 2007. [13] RUOTSALAINEN, R., Indoor climate and the performance of ventilation in Finnish residences. Indoor Air, 2, 137-145. 1992. [14] DYHR R., Asuinrakennusten ilmanvaihtoselvitys. Helsingin kaupunki. 1993. [15] D2. Suomen rakentamismääräyskokoelma. Rakennusten sisäilmasto ja ilmanvaihto. Määräykset ja ohjeet 1987, Ympäristöministeriö, 1987. [16] D2. Suomen rakentamismääräyskokoelma. Rakennusten sisäilmasto ja ilmanvaihto. Määräykset ja ohjeet 2003, Ympäristöministeriö, Rakennetun ympäristön osasto. 2003. [17] D2. Suomen rakentamismääräyskokoelma. Rakennusten sisäilmasto ja ilmanvaihto. Määräykset ja ohjeet 2010, Ympäristöministeriö, Rakennetun ympäristön osasto. 2010. [18] MOTIVA OY, Pientalon lämmitysjärjestelmät. Helsinki, 2009. [19] VIRTA, J. JA PYLSY P., Taloyhtiön energiakirja. Kiinteistöalan kustannus oy. 2011. [20] D5 Suomen rakentamismääräyskokoelma, Rakennuksen energiankulutuksen ja lämmitystehontarpeen laskenta Ohjeet 2007. Ympäristöministeriö, Asunto- ja rakennusosasto. Helsinki 19.kesäkuuta 2007.