MONTERINGSANVISNING EXTRA SHUNT ESV 22 TILL NIBE SPLIT INSTALLATION INSTRUCTIONS EXTRA SHUNT ESV 22 FOR NIBE SPLIT



Samankaltaiset tiedostot
INSTALLATION INSTRUCTIONS EXTRA SHUNT ESV 28 FOR HBS 16 MONTAGEANLEITUNG EXTRA MISCHGRUPPE ESV 28 FÜR HBS 16

Asentajan käsikirja VPB/VPBS. Lämminvesivaraaja IHB FI LEK

F2015/F2016/F2025/F2026/F2030/F2300

ETS 12 / 121. Huom! Huom! Komponenttiluettelo. Yleistä. Komponentit. Varatila

ASENNUS- JA KÄYTTÖOHJEET MOS FI HK: 150/200/ HK 150, 200, 300 LEK

ELK ELK 26 LEK

LEK LEK ECS 40/ECS 41

Asentajan käsikirja VPB 200/VPB 300. Lämminvesivaraaja IHB FI LEK

MONTERINGSANVISNING VÄXELVENTIL, KYLA VCC 22 TILL NIBE SPLIT INSTALLATION INSTRUCTIONS SHUTTLE VALVE, COOLING VCC 22 FOR NIBE SPLIT

Asentajan käsikirja AHP/AHPS

MOS FI FJVM ASENNUS- JA HOITO-OHJEET FJVM 120 FIGHTER 310P/360P LEK

Käyttöohjekirja NIBE SAM 40

SIRIUS valaisin on asemoitava siten, ettei pitkäaikaista katsomista valaisimeen voi olettaa tapahtuvan 2,3m lähempää.

MONTERINGSANVISNING VÄXELVENTIL, KYLA VCC 28 TILL HBS 16 INSTALLATION INSTRUCTIONS SHUTTLE VALVE, COOLING VCC 28 FOR HBS 16

Asennusohje alashunttaukselle NIBE F1145/F1245

MOS FI HK: ASENNUS- JA HOITO-OHJEET HK 15 ASENNUS- JA HOITO-OHJE, RUOSTUMATTOMILLE LÄMMINVESIVARAAJILLE

ASENNUSOHJE KÄYTTÖVEDEN LÄMMITYKSEN OHJAUS VST 114/VST 200 MONTERINGSANVISNING VARMVATTENSTYRNING VST 114/VST 200

ELK ELK 42 LEK

LEK EXC 40. Installatörshandbok EXC 40. Installer manual EXC 40. Installateurhandbuch EXC 40. Asentajan käsikirja EXC 40 IHB

ASENNUS- JA KÄYTTÖOHJEET MOS FI HK: 150/200/ HK 150, 200, 300 LEK

Asennusohje ilmaiskylmälle NIBE F1145/F1245

MOS FI ASENNUS- JA HOITO-OHJEET ELK ELK 26 LEK

Asentajan käsikirja AXC 40. Lisätarvikkeet IHB FI LEK

Asennusohje AXC 40 IHB FI AXC 40 IHB FI 1

Alfa Q TW 56W Alfa Q 58W GLAQTW00056 GLAQ W 58 W 5300 lm 5400 lm

NIBE F1155/F1255. Elschema. Wiring diagram. Elektrischer Schaltplan IHB SE

Käyttöohjekirja NIBE SAM 41

Käyttö- ja asennusohje NIBE UKV 20

Asentajan käsikirja AHP/AHPS

SQUARE. Greenled Tarjusojantie Kempele FINLAND

Asentajan käsikirja AXC 40

ASENNUSOHJE IHB FI POOL 40 IHB FI 1

FJVM FIGHTER 310P/410P/360P

KVR 10. Installatörshandbok Kondensvattenrör KVR 10. Installer manual Kondensvattenrör KVR 10. Installateurhandbuch Kondensvattenrör KVR 10

Asentajan käsikirja VPB 200. Varaajasäiliö IHB FI LEK

Anvisning till VDM6A för rundpumpning med seriekoppling

Asentajan käsikirja SMO 40

Asentajan käsikirja AXC 40. Lisätarvikkeet IHB FI

SOLAR 41. Installatörshandbok SOLAR 41. Installer manual SOLAR 41. Installateurhandbuch SOLAR 41. Asentajan käsikirja SOLAR 41 IHB LEK

LYTH-CONS CONSISTENCY TRANSMITTER

Svenska, Installatörshandbok - PCS 44

ECO E II. Greenled Tarjusojantie Kempele FINLAND

MOS FI HK: ASENNUS- JA HOITO-OHJEET HK 15 ASENNUS- JA HOITO-OHJE, RUOSTUMATTOMILLE LÄMMINVESIVARAAJILLE

PCS 44 IHB LEK Type UPS P/N: LEK LEK. Max. 10bar TF 110 IP 44. Class H PC;0017NIB

Käyttö- ja asennusohje VPB/VPBS

-BT1 -QM31 -XL15 -HQ1 -EB100 F1145

MOS SE ER57-R 300 Finland MONTERINGS- OCH SKÖTSELANVISNING COMPACT R 300. MONTERINGS- OCH SKÖTSELANVISNING Compact

Asentajan käsikirja SAM 40. Tuloilmamoduuli IHB FI LEK

Svenska, Installatörshandbok - PCS 44

SIRIUS valaisin on asemoitava siten, ettei pitkäaikaista katsomista valaisimeen voi olettaa tapahtuvan 2,3m lähempää.

SIGMA 77W SIGMA 117W SIGMA 155W SIGMA 235W GLSI00077 GLSI00117 GLSI00155 GLSI W 117 W 155 W 235 W lm lm lm lm

GAMMA. Greenled Oy Tarjusojantie FI Kempele, Finland

ECO S. Greenled Oy Tarjusojantie FI Kempele, Finland

SIRIUS valaisin on asemoitava siten, ettei pitkäaikaista katsomista valaisimeen voi olettaa tapahtuvan DIM * lähempää.

Asentajan käsikirja MCU 40. Lisätarvikkeet. Lisävarustekortti IHB FI

mini Safe by Design and optimized for tilting windows

Käyttöohjekirja NIBE F , 12, 16 kw Ilma/vesi-lämpöpumppu UHB FI LEK LEK LEK

Asentajan käsikirja VPB/VPBS

NIBE ILMAVESILÄMPÖPUMPPUOPAS OSA 1: SISÄYKSIKÖT VVM 310 VVM 320 VVM 500

Asentajan käsikirja SAM 40. Tuloilmamoduuli IHB FI LEK

Lämpöä tai jäähdytystä Tarpeen mukaan

Asentajan käsikirja NIBE F1226. Maalämpöpumppu IHB FI LEK

Asentajan käsikirja SAM 40. Tuloilmamoduuli IHB FI LEK

Vakiomallisten kuumakanavajärjestelmien kytkeminen Wiring of standard hotrunner systems

SCA 41 IHB

Linear S/SI/SR/P. Asennusohje Monteringsanvisning

Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Muutokset sallittu vain sertifikaatin my

DEW 40 IHB Installatörshandbok Dockningssats för F750 med VPB 200. Installer manual Docking kit for F750 with VPB 200

Asentajan käsikirja AXC 40

Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Muutokset sallittu vain sertifikaatin my

I-VALO LED 6721 RETROFIT instructions

Installatörshandbok SCA 41 IHB SE

HOO B00 - B01 HOO B20 - B24

TSL-peilikaappi TSL-spegelskåp. TST-peilikaappi TST-spegelskåp. Asennusohje Monteringsanvisning

Sijoita ulkoyksikkö siten, että se on mahdollisimman hyvin tuulelta suojassa. Tämä edesauttaa laitteen toimintaa sulatusvaiheessa.

Käyttöohjekirja NIBE SMO 20. Ohjausyksikkö UHB FI LEK

Installatörshandbok - SCA 41

Käyttöohjekirja NIBE F2026

Varaosaluettelo Rerservdelslista Spare parts list Ersatzteilliste. [Type text]

Asennus, venttiilisarja TBVL GOLD/COMPACT

Asentajan käsikirja AXC 50. Lisätarvikkeet IHB FI LEK

Arbetsplatsarmatur och badrumsarmatur Work-point and Bathroom luminaire Työpiste- ja kylpyhuonevalaisin. Onndeli Onnsani

NIBE SPLIT ILMA/VESILÄMPÖPUMPPU. Lämpöä tai viilennystä, tarpeen mukaan NIBE SPLIT

Asennusopas. DEVIreg 531. Elektroninen termostaatti.

Sähkökattila EVC 13. Kompakti sähkökattila ulkolämpötilaohjatulla lämpöautomatiikalla, kuormitusvahdilla, paisuntasäiliöllä ja kiertopumpulla

Käyttöohjekirja NIBE VVM 320. Sisäyksikkö UHB FI APH

Käyttöohjekirja AMS 10 AMS 10-6 / 10-8 / / 10-16

National Building Code of Finland, Part D1, Building Water Supply and Sewerage Systems, Regulations and guidelines 2007

POISTOILMALÄMPÖPUMPPUJEN ASENTAJAN OPAS

Asentajan käsikirja. SE-PV 3031 Aurinkokennopaketti. Lisätarvikkeet IHB FI

SCA 40 IHB

MOS FI VEDEX ASENNUS- JA HOITO-OHJEET VEDEX 3300 LEK

Käyttöohjekirja NIBE F2040

ASENNUSOHJE / INSTALLATIONSANVISNINGAR / INSTALLATION INSTRUCTIONS. PA KAIVO SA tarvikeluettelo/ förteckning över utrustning/ list of equipment:

Fitting instructions. Fitting set for joining all types of DEVI self limiting heating cables to heating cables Art. no SSTL nro

Käyttöohjekirja HBS 05 HBS 05-6 / / 05-16

Yhtiön nimi: - Luotu: - Puhelin: - Fax: - Päiväys: -

PCS 44. Installatörshandbok Passiv kyla SE. Installer manual Passive cooling GB. Installateurhandbuch Passive Kühlung DE

Käyttöohjekirja F2040 6, 8, 12, 16

Exercise 1. (session: )

Transkriptio:

230V- 50Hz 2.5uF 1m(A) P,(W) 0.20 0.30 0.40 45 65 90 HEJSAN PC;0017NIB DK IP 44 TF 110 Class H Max. 10bar MAV 0935-2 031261 SE MONTERINGSANVISNING EXTRA SHUNT TILL NIBE SPLIT GB INSTALLATION INSTRUCTIONS EXTRA SHUNT FOR NIBE SPLIT DE FI MONTAGEANLEITUNG EXTRA MISCHGRUPPE FÜR NIBE SPLIT ASENNUSOHJE LISÄSHUNTTIRYHMÄLLE KÄYTETTÄVÄKSI NIBE SPLIT KANSSA Type UPS 25-60 130 P/N:59526447 GRUNDFOS LEK LEK

MONTERINGSANVISNING SE Allmänt Innehåll Detta tillbehör används då NIBE ACVM 270 installeras i hus med två olika värmesystem som kräver olika framledningstemperaturer, t.ex. då huset har både radiatorsystem och golvvärmesystem. I nedanstående text avser värmesystem 1 det system som kräver den högre temperaturen och som kopplas in till den ordinarie framlednings- respektive returledningsanslutningen. Värmesystem 2 avser det värmesystem som arbetar med lägre temperatur. Vattenflödet i de två värmesystemen tillsammans bör ej överstiga 2050 l/h (0,57 l/s). OBS! Detta tillbehör kräver även tillbehöret ACK 22. 1st 4st 2st 1st 2st 4st 1st 2st 1st 2st 2st 1st 3-ledare för cirkulationspump Buntband Värmeledningspasta Isoleringstejp Planpackning Rundhylsa Cirkulationspump Union 3-hastighet, EP21-GP20 Kulventil M Unionsmutter 3-vägsventil Aluminiumtejp (bitar) Temperaturgivare, EP21-BT2 (framledningsgivare), EP21-BT3 (returledningsgivare) Reglermotor, EP21-QN25 3

SE Röranslutning ACVM 270 Pump- och tryckfallsdiagram Montering sker enligt följande: Töm först pannvattenkärlet/värmesystemet om detta är vattenfyllt. Den extra värmebärarpumpen (EP21-GP20) placeras på lämplig plats utanför ACVM 270. Shuntventilen (EP21-QN25) placeras på framledningen efter ACVM 270, före första radiator på värmesystem 1. Returledningen från värmesystem 2 kopplas till shuntventilen (EP21-QN25) samt till returledningen från värmesystem 1, se bild. Framledningsgivaren (EP21-BT2) monteras på röret efter värmebärarpumpen (EP21-GP20). Returledningsgivaren (EP21-BT3) monteras på röret från värmesystem 2. Vid montering av givare skall värmeledningspasta användas samt röret isoleras för att erhålla korrekt temperaturmätning. Tillgängligt tryck, kpa kpa 70 60 50 40 30 20 10 0 0 200 400 0 0,1 600 800 0,2 1 1000 1200 0,3 3 2 Flöde Flöde 1400 1600 1800 2000 l/h 0,4 0,5 l/s OBS! Vid felaktig montering kan funktionen äventyras. LEK Shuntventil, (EP21-QN25) Anslutningar, Ø 22 mm Retur ACVM 270 Framledning LEK 4

SE Principschema ACVM 270 med - extra shunt EP21-QN25 EP21-GP20 EP21-BT2 EP21-BT3 RG10/ RE10 UKV40 CP1 GP10 Överströmningsventil ventil CM1 Erf. säkerhetsutr. Erforderlig säkerhetsutr. FQ1 FL1 BT 1 Förklaring BT1 Temperaturgivare, utomhus EP21-BT2 Temperaturgivare, framledning 2 EP21-BT3 Temperaturgivare, returledning 2 CM1 Expansionskärl CP1 EP21-GP20 EP21-QN25 Utjämningskärl UKV Extra cirkulationspump Shuntventil 5

SE Elinkoppling ACVM 270 - Returledningsgivaren (EP21-BT3) kopplas in till position AA22:X4:5 och AA22:X4:6 på samma kort. OBS! All elektrisk inkoppling skall ske av behörig elektriker. Elektrisk installation och ledningsdragning skall utföras enligt gällande bestämmelser. ACVM 270 ska vara spänningslös vid installation av. Elscheman finns i slutet av denna monteringsanvisning. 3. Ventilställdonet (EP21-QN25) anslutes enligt följande: - Brun ledare (230 V signal) till fjäderplinten X6:7b - Vit ledare (230 V signal) till fjäderplinten X6:8a - Blå ledare (nolla) till fjäderplinten X6:6b 4. Cirkulationspumpen (EP21-GP20) anslutes enligt följande: - Blå ledare (nolla) till fjäderplinten X6:6a - Gul/grön ledare (jordledare) till fjäderplinten X6:5a - Brun ledare (fas) till fjäderplinten X6:4a Från Vit Brun Blå Elkoppling, X6 8 7 6 Elkoppling, X6 EBV AA22 Gul/grön Brun 5 4 3 2 1 AA22:X4 Montering av temperaturgivare K 1. Tillbehöret ACK 22 installeras enligt medföljande monteringsanvisning. 2. Givarna kopplas in med tvåledare (exempelvis EKXX eller LiYY) enligt följande till effektvaktskortet (EBV AA22) se bild nedan: Använd medföljande rundstiftshylsor för skarvning mellan 2-ledarna och givarna BT2 och BT3. Temperaturgivaren monteras med buntband tillsammans med värmeledningspasta och aluminiumtape. Därefter skall den isoleras med medföljande isolertape. -AA22 EBV-kort >-EP21 Värmesystem 2 (Tillbehör) Tempgivare framledning 2 OBS! Givar- och kommunikationskablar får ej förläggas i närheten av starkströmsledning. X4 Tempgivare returledning 2 - Den givare som används som framledningsgivare (EP21-BT2) ansluts till position AA22:X4:7 och AA22:X4:8 i effektvaktskortets nedre plint. 6

SE Programinställningar ACVM 270 Välj Service i meny 8.1.1 för att få tillgång till meny 9.0 och dess undermenyer. Välj sedan Värme, "Värme + Kyla" eller "Kyla" i meny 9.3.4, Värmesystem 2. Därmed blir meny 3.0 och dess undermenyer åtkomliga. I undermenyerna ställs nu kurvlutning 2, förskjutning värmekurva 2 samt min- och maxnivåer för framledningstemperatur 2 in på samma sätt som för värmesystem 1 under meny 2.0. Se också Monterings- och skötselanvisning för NIBE SPLIT. 7

SE 8

INSTALLATION INSTRUCTIONS GB General Contents This accessory is used when NIBE ACVM 270 is installed in houses with two different heating systems that require different flow line temperatures, for example, in cases where the house has both a radiator system and an under floor heating system. In the following text Heating system 1 covers the system that requires the greater temperature and that is connected to the normal flow line respectively return line connection. Heating system 2 covers the heating system that works at the lower temperature. The water flow in the two heating systems should not exceed 2050 l/h (0,57 l/s). NOTE This accessory also requires accessory ACK 22. 1x 4x 2x 1x 2x 4x 1x 2x 1x 2x 2x 1x 3 wire circulation pump Cable ties Heating pipe paste Insulation tape Flat gasket Round sleeve Circulation pump Union 3-speed, EP21-GP20 Ball valve M Swivel nut 3-way valve Aluminium tape (pieces) Temperature sensor, EP21-BT2 (flow sensor), EP21- BT3 (return sensor) Control motor, EP21-QN25 9

GB Pipe connections ACVM 270 Pump and pressure drop diagrams Install as follows: First drain the boiler water reservoir/heating system if filled with water. Position the extra heat medium pump (EP21-GP20) in a suitable location outside ACVM 270. The shunt valve (EP21-QN25) is located on the flow line after ACVM 270, before the first radiator in the heating system 1. The return line from heating system 2 is connected to the shunt valve (EP21-QN25) and to the return line from heating system 1, see illustration. The flow sensor (EP21-BT2) is installed on the pipe after the heat medium pump (EP21-GP20). The return line sensor (EP21-BT3) is installed on the pipe from heating system 2. When installing the sensor, heat conducting paste must be used and the pipe must be insulated to obtain the correct temperature measurement. Available pressure, kpa kpa 70 60 50 40 30 20 10 0 0 200 400 0 0,1 600 800 0,2 1 1000 1200 0,3 3 2 Flow Flöde 1400 1600 1800 2000 l/h 0,4 0,5 l/s NOTE Incorrect installation can affect the function. LEK By-pass valve, (EP21-QN25) Connections, Ø 22 mm Return ACVM 270 Flow pipe LEK 10

GB Outline diagram ACVM 270 with - extra shunt EP21-QN25 EP21-GP20 EP21-BT2 EP21-BT3 RG10/ RE10 UKV40 CP1 GP10 Överströmnings Overflow valve ventil CM1 Erf. säkerhetsutr. safety Required equipment FQ1 FL1 BT 1 Explanation BT1 Temperature sensor, outdoor EP21-BT2 Temperature sensor, supply line 2 EP21-BT3 Temperature sensor, return 2 CM1 Expansion vessel CP1 EP21-GP20 EP21-QN25 Buffer vessel UKV Extra circulation pump Shunt valve 11

GB Electrical connection ACVM 270 NOTE All electrical connections must be carried out by an authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. ACVM 270 must not be powered when installing ESV 22. The electrical circuit diagram is at the end of these installation instructions. From - - The sensor used as flow sensor (EP21-BT2) is connected to terminal AA22:X4:7 and AA22:X4:8 in the load monitor card's lower terminal block. The return line sensor (EP21-BT3) is connected to terminal AA22:X4:5 and AA22:X4:6 on the same card. 3. Connect valve actuator (EP21-QN25) as follows: - Brown cable (230 V signal) to spring terminal X6:7b - White cable (230 V signal) to spring terminal X6:8a - Blue cable (zero) to spring terminal X6:6b 4. Connect circulation pump (EP21-GP20) as follows: - Blue cable (zero) to spring terminal X6:6a - Yellow/green cable (earth cable) to spring terminal X6:5a - Brown cable (phase) to spring terminal X6:4a Electrical connection, X6 White Brown Blue Electrical connection, X6 8 7 6 Yellow/green Brown 5 4 EBV AA22 AA22:X4 3 2 1 Temperature sensor installation 1. The accessory ACK 22 is installed according to the supplied installation instructions. 2. The sensors are connected by twin cables (for example EKXX or LiYY) as follows for the load monitor card (EBV AA22) see image below: Use the enclosed round pin sleeves for splicing between the 2-cables and sensors BT2and BT3. -AA22 EBV Control Card >-EP21 Heating System 2 (Optional) K Install the temperature sensor with cable ties with the heat conducting paste and aluminium tape. Then insulate with supplied insulation tape. X4 Temp. sensor supply line 2 Temp. sensor return 2 NOTE Sensor and communication cables must not be placed near power cables. 12

GB Program settings ACVM 270 Select Service in menu 8.1.1 to gain access to menus 9.0 and the sub-menus. Then select Heating, "Heating + Cooling" or "Cooling" in menu 9.3.4, Heating system 2. Menu 3.0 and its sub-menus become accessible. In the sub-menus the curve co-efficient 2, offset heat curve 2 and min- and max levels for the flow line temperature 2 are set in the same way as heat system 1 under menu 2.0. See Installation and Maintenance Instructions for NIBE SPLIT. 13

GB 14

MONTAGEANLEITUNG DE Allgemeines Dieses Zubehör kommt zum Einsatz, wenn ACVM 270 in einem Haus mit zwei verschiedenen Heizkreisen installiert ist, die unterschiedliche Vorlauftemperaturen erfordern, z.b. wenn ein Gebäude über Heizkörper und Fußbodenheizung verfügt. Im folgenden Text gilt Heizkreis 1 als das System, das die höhere Temperatur erfordert und das mit dem normalen Vorlauf- bzw. Rücklaufanschluss verbunden wird. Als Heizkreis 2 gilt das System, das mit der niedrigeren Temperatur arbeitet. Der kombinierte Wasserdurchfluss in beiden Heizkreisen darf 2050 l/h (0,57 l/s) nicht überschreiten. HINWEIS! Dieses Zubehör erfordert ebenfalls das Zubehör ACK 22. Inhalt 1 St. 4 St. 2 St. 1 St. 2 St. 4 St. 1 St. 2 St. 1 St. 2 St. 2 St. 1 St. 3-Leiter-Umwälzpumpe Kabelbinder Wärmeleitpaste Isolierband Flachdichtung Buchse Umwälzpumpe Überwurfmutter 3 Geschwindigkeiten, EP21-GP20 Kugelventil M Überwurfmutter 3-Wegeventil Aluminiumklebeband (Abschnitte) Fühler, EP21-BT2 (Vorlauffühler), EP21-BT3 (Rücklauffühler) Stellantrieb, EP21-QN25 15

DE Rohranschluss ACVM 270 Pumpenkennliniendiagramm Führen Sie die Montage wie folgt durch: Entleeren Sie zuerst das Wasser aus dem Heizwassergefäß/Heizkreis. Positionieren Sie die zusätzliche Heizungsumwälzpumpe (EP21-GP20) an einer geeigneten Stelle außerhalb von ACVM 270. Bringen Sie das Mischventil (EP21-QN25) am Vorlauf hinter dem ACVM 270 und vor dem ersten Heizkörperfür Heizkreis 1 an. Verbinden Sie die Rücklaufleitung von Heizkreis 2 mit dem Mischventil (EP21-QN25) und der Rücklaufleitung vom Heizkreis 1 (siehe Abbildung). Der Vorlauffühler (EP21-BT2) wird am Rohr nach der Heizungsumwälzpumpe (EP21-GP20) montiert. Der Rücklauffühler (EP21-BT3) wird am Rohr von Heizkreis 2 montiert. Verwenden Sie bei der Fühlermontage Wärmeleitpaste und isolieren Sie das Rohr, um eine korrekte Temperaturmessung zu gewährleisten. Verfügbarer Druck, kpa kpa 70 60 50 40 30 20 10 0 0 200 400 0 0,1 600 800 0,2 1 1000 1200 0,3 3 2 Fluss Flöde 1400 1600 1800 2000 l/h 0,4 0,5 l/s HINWEIS! Bei einer falschen Montage kann die Funktionsweise beeinträchtigt werden. LEK Mischventil, (EP21-QN25) Anschlüsse, Ø 22 mm Rücklauf ACVM 270 Vorlauf LEK 16

DE Prinzipskizze ACVM 270 mit zusätzliches Mischventil EP21-QN25 EP21-GP20 EP21-BT2 EP21-BT3 RG10/ RE10 UKV40 CP1 CM1 GP10 Överströmnings Überlaufventil Erforderliche Erf. säkerhetsutr. Sicherheitsausr. FQ1 FL1 BT 1 Erklärung BT1 Außentemperaturfühler EP21-BT2 Fühler, Vorlauf 2 EP21-BT3 Fühler, Rücklauf 2 CM1 Ausdehnungsgefäß CP1 EP21-GP20 EP21-QN25 Pufferspeicher UKV Zusätzliche Umwälzpumpe Mischventil 17

DE Elektrischer Anschluss ACVM 270 HINWEIS! Alle elektrischen Anschlüsse müssen von einem befugten Elektriker ausgeführt werden. Bei der Elektroinstallation und beim Verlegen der Leitungen sind die geltenden Vorschriften zu berücksichtigen. ACVM 270 darf bei der Installation von nicht mit Spannung versorgt werden. Der Schaltplan befindet sich am Ende dieser Montageanleitung. Aus - - Der als Vorlauffühler verwendete Fühler (EP21-BT2) wird mit Position AA22:X4:7 und AA22:X4:8 an der unteren Anschlussklemme der Leistungswächterkarte verbunden. Rücklauffühler (EP21-BT3) wird mit Position AA22:X4:5 und AA22:X4:6 an derselben Karte verbunden. 3. Ventilstellvorrichtung (EP21-QN25) wird wie folgt angeschlossen: - Brauner Leiter (230-V-Signal) an Federklemme X6:7b - Weißer Leiter (230-V-Signal) an Federklemme X6:8a - Blauer Leiter (Nullleiter) an Federklemme X6:6b. 4. Umwälzpumpe (EP21-GP20) wird wie folgt angeschlossen: - Blauer Leiter (Nullleiter) an Federklemme -X6:6a - Gelber/grüner Leiter (Erdleiter) an Federklemme - X6:5a - Brauner Leiter (Phase) an Federklemme -X6:4a Elektrischer Anschluss, X6 Weiß Braun Blau Elektrischer Anschluss, X6 8 7 6 EBV AA22 AA22:X4 Gelb/Grün Braun 5 4 3 2 1 1. Das Zubehör ACK 22 wird gemäß der beiliegenden Montageanleitung installiert. 2. Die Fühler werden wie folgt per Zweileiter (z.b. EKXX oder LiYY) mit der Leistungswächterkarte verbunden (EBV AA22) siehe Abbildung unten. Verwenden Sie die folgenden Rundstifthülsen, um 2-Leiter sowie Fühler BT2 und BT3 zu verbinden. -AA22 EBV-Karte >-EP21 Heizsystem 2 (Zubehör) Temp.fühler, Vorlauf 2 X4 Temp.fühler, Rücklauf 2 18

DE Fühlermontage K Der Fühler wird mit Kabelbinder, Wärmeleitpaste und Aluminiumband angebracht. Anschließend ist er mit dem beiliegenden Isolierband zu umwickeln. HINWEIS! Fühler- und Kommunikationskabel dürfen nicht in der Nähe von Starkstromleitungen verlegt werden. Programmeinstellungen ACVM 270 Durch Auswahl von "Service" in Menü 8.1.1 erhalten Sie Zugriff auf Menü 9.0 und die zugehörigen Untermenüs. Wählen Sie anschließend Heizung, "Heizung + Kühlung" oder "Kühlung" im Menü 9.3.4, "Heizkreis 2" aus. Dadurch erhalten Sie Zugriff auf Menü 3.0 und die zugehörigen Untermenüs. In den Untermenüs werden Heizkurvenverlauf 2, Parallelverschiebung der Heizkurve 2 sowie Minimal- und Maximalwerte für Vorlauftemperatur 2 auf dieselbe Weise wie für Heizkreis 1 unter Menü 2.0 eingestellt. Siehe auch "Montage- und Wartungsanleitung" für NIBE SPLIT. 19

DE 20

ASENNUSOHJE FI Yleistä Sisältö Tätä lisävarustetta käytetään, kun NIBE ACVM 270 asennetaan taloon, jossa on kaksi erilaista lämmitysjärjestelmää, jotka edellyttävät eri menolämpötiloja, esimerkiksi silloin, kun talossa on sekä lattialämmitys- että patterijärjestelmä. Alla olevassa tekstissä lämmitysjärjestelmä 1 tarkoittaa korkeampaa lämpötilaa vaativaa järjestelmää, joka kytketään tavalliseen meno- ja paluuliitäntään. Lämmitysjärjestelmä 2 tarkoittaa alhaisemmalla menolämpötilalla toimivaa lämmitysjärjestelmää. Lämmitysjärjestelmien yhteenlaskettu vesivirta ei saa olla yli 2050 l/h (0,57 l/s) HUOM! Tämä lisävaruste vaatii lisävarusteen ACK 22. 1 kpl 4 kpl 2 kpl 1 kpl 2 kpl 4 kpl 1 kpl 2 kpl 1 kpl 2 kpl 2 kpl 1 kpl 3-napainen johdin kiertovesipumpulle Nippuside Lämmönjohtotahna Eristysteippi Tasotiiviste Holkki Kiertovesipumppu Union 3-nopeuksinen, EP21-GP20 Palloventtiili M liitosmutteri 3-tieventtiili Alumiiniteippi (palat) Lämpötila-anturi, EP21-BT2 (menolämpötilan anturi), EP21-BT3 (paluulämpötilan anturi) Säätömoottori EP21-QN25 21

FI PutkiasennuksetACVM 270 Pumppu- ja painehäviökäyrä Asennus tapahtuu seuraavasti: Tyhjennä tarvittaessa kattilavesi/lämmitysjärjestelmä. Lisäkiertovesipumppu (EP21-GP20) asennetaan sopivalle paikalle ACVM 270 ulkopuolelle. Shunttiventtiili (EP21-QN25) asennetaan menojohtoon ACVM 270:n jälkeen ennen lämmitysjärjestelmän 1 ensimmäistä patteria. Paluujohto lämmitysjärjestelmästä 2 kytketään shunttiventtiiliin (EP21-QN25) ja paluujohtoon lämmitysjärjestelmästä 1, katso kuva Menolämpötilan anturi (EP21-BT2) asennetaan putkeen kiertovesipumpun (EP21-GP20) jälkeen. Paluulämpötilan anturi (EP21-BT3) asennetaan putkeen lämmitysjärjestelmästä 2. Anturin asennuksen yhteydessä on käytettävä lämmönjohtotahnaa ja putket pitää eristää oikean lämpötilamittauksen varmistamiseksi. Käytettävissä oleva paine kpa kpa 70 60 50 40 30 20 10 0 0 200 400 600 800 0 0,1 0,2 1 1000 1200 0,3 3 2 Virtaus Flöde 1400 1600 1800 2000 l/h 0,4 0,5 l/s HUOM! Virheellisen asennuksen yhteydessä toiminta saattaa vaarantua. LEK Shunttiventtiili, (EP21-QN25) Liitännät, Ø 22 mm Paluu ACVM 270 Menojohto LEK 22

FI Periaatekaavio ACVM 270 ja - lisäshuntti EP21-QN25 EP21-GP20 EP21-BT2 EP21-BT3 UKV40 CM1 RG10/ RE10 CP1 GP10 Överströmnings Ohitusventtiili ventil Erf. säkerhetsutr. Vaadittu turvavarustus FQ1 FL1 BT 1 Selvitys BT1 EP21-BT2 EP21-BT3 CM1 Lämpötilan anturi, ulko Lämpötila-anturi, menojohto 2 Lämpötila-anturi, paluujohto 2 Paisuntasäiliö CP1 EP21-GP20 EP21-QN25 Puskurisäiliö UKV Lisäkiertovesipumppu Shunttiventtiili 23

FI Sähkökytkentä ACVM 270 - Paluulämpötilan anturi (EP21-BT3) kytketään saman kortin paikkoihin AA22:X4:5 ja AA22:X4:6. HUOM! Sähköasennukset saa tehdä vain valtuutettu sähköasentaja. Sähköasennukset ja johtimien veto on tehtävä voimassa olevien määräysten mukaisesti. ACVM 270:n pitää olla jännitteetön :n asennuksen aikana. Kytkentäkaavio on tämän asennusohjeen lopussa. 3. Venttiilitoimilaite (EP21-QN25) kytketään seuraavasti: - Ruskea johdin (230 V signaali) jousiliittimeen X6:7b - Valkoinen johdin (230 V signaali) jousiliittimeen X6:8a - Sininen johdin (nolla) jousiliittimeen X6:6b 4. Kiertovesipumppu EP21-GP20 kytketään seuraavasti: - Sininen johdin (nolla) jousiliittimeen X6:6a - Kelta/vihreä johdin (suojamaa) jousiliittimeen X6:5a - Ruskea johdin (vaihe) jousiliittimeen X6:4a hkökytkentä, X6 EBV AA22 :sta Valkoinen Ruskea Sininen Keltainen/vihreä Ruskea Sähkökytkentä, X6 8 7 6 5 4 3 2 1 AA22:X4 Lämpötila-anturin asennus K 1. Lisävaruste ACK 22 asennetaan oheisen asennusohjeen mukaan. 2. Anturit kytketään kaksinapaisella johtimella (esim. EKXX tai LiYY) valvontakytkinkorttiin (EBV AA22) katso kuva alla: Käytä mukana toimitettuja liitinholkkeja 2-napaisen johtimen ja anturien BT2 ja BT3 välisissä liitoksissa. Lämpötila-anturit asennetaan nippusiteillä lämmönjohtotahnan ja alumiiniteipin kanssa. Sen jälkeen se eristetään mukana toimitetulla eristysteipillä. -AA22 EBV-kortti >-EP21 Lämmitysjärjestelmä 2 (lisävaruste) Menolämpötilan anturi 2 HUOM! Anturi- ja tiedonsiirtokaapeleita ei saa vetää vahvavirtajohtojen läheisyydessä. X4 Paluulämpötilan anturi 2 - Menolämpötilan anturi (EP21-BT2) kytketään valvontakytkinkortin alemman riman paikkoihin AA22:X4:7 ja AA22:X4:8. 24

FI Ohjelman asetukset ACVM 270 Valitse "Huolto" valikosta 8.1.1, niin että pääset valikkoon 9.0 ja sen alivalikoihin. Valitse sitten Lämmitys, "Lämmitys + Jäähdytys" tai "Jäähdytys" valikossa 9.3.4, Lämmitysjärjestelmä 2. Tällöin valikko 3.0 ja sen alavalikot tulevat näkyviin. Aseta nyt alavalikoissa käyrän kaltevuus 2, lämpökäyrän muutos 2 sekä menolämpötilan 2 minimi- ja maksimiarvot samalla tavoin kuin lämmitysjärjestelmälle 1 valikossa 2.0. Katso myös NIBE SPLIT asennus- ja huolto-ohjeet. 25

FI 26

Elschema/Wiring diagram/elektrischer schaltplan/sähkökaavio 27

28

29

30

AT KNV Energietechnik GmbH, Gahberggasse 11, 4861 Schörfling Tel: +43 (0)7662 8963-0 Fax: +43 (0)7662 8963-44 E-mail: mail@knv.at www.knv.at CH NIBE Wärmetechnik AG, Winterthurerstrasse 710, CH-8247 Flurlingen Tel: (52) 647 00 30 Fax: (52) 647 00 31 E-mail: info@nibe.ch www.nibe.ch CZ Druzstevni zavody Drazice s.r.o, Drazice 69, CZ - 294 71 Benatky nad Jizerou Tel: +420 326 373 801 Fax: +420 326 373 803 E-mail: nibe@nibe.cz www.nibe.cz DE NIBE Systemtechnik GmbH, Am Reiherpfahl 3, 29223 Celle Tel: 05141/7546-0 Fax: 05141/7546-99 E-mail: info@nibe.de www.nibe.de DK Vølund Varmeteknik, Filial af NIBE AB, Brogårdsvej 7, 6920 Videbæk Tel: 97 17 20 33 Fax: 97 17 29 33 E-mail: info@volundvt.dk www.volundvt.dk FI NIBE Haato OY, Valimotie 27, 01510 Vantaa Puh: 09-274 697 0 Fax: 09-274 697 40 E-mail: info@haato.com www.haato.fi GB NIBE Energy Systems Ltd, 3C Broom Business Park, Bridge Way, Chesterfield S41 9QG Tel: 0845 095 1200 Fax: 0845 095 1201 E-mail: info@nibe.co.uk www.nibe.co.uk NL NIBE Energietechniek B.V., Postbus 2, NL-4797 ZG WILLEMSTAD (NB) Tel: 0168 477722 Fax: 0168 476998 E-mail: info@nibenl.nl www.nibenl.nl NO NIBE AB, Fekjan 15F, 1394 Nesbru Tel: 22 90 66 00 Fax: 22 90 66 09 E-mail: info@nibe.se www.nibevillavarme.no PL NIBE-BIAWAR Sp. z o. o. Aleja Jana Pawła II 57, 15-703 BIAŁYSTOK Tel: 085 662 84 90 Fax: 085 662 84 14 E-mail: sekretariat@biawar.com.pl www.biawar.com.pl NIBE AB Sweden, Box 14, Järnvägsgatan 40, SE-285 21 Markaryd Tel: +46-(0)433-73 000 Fax: +46-(0)433-73 190 E-mail: info@nibe.se www.nibe.eu