Äänitasomittarit. Äänitasomittari luokka 2 CR:262A 26..140db,integroiva. ilmanvaihdon melun mittaukseen.



Samankaltaiset tiedostot
Äänianalysaattori Optimus Vihreä ympäristömelu ja meluanalysointi

Äänitasomittarit. Meluhälytin SoundSign

TÄYTTÖAUTOMAATIT TÄYTTÖAUTOMAATIT COMPUTER INFLATORS

WindPRO version joulu 2012 Printed/Page :47 / 1. SHADOW - Main Result

Capacity Utilization

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

Metsälamminkankaan tuulivoimapuiston osayleiskaava

Microsoft Lync 2010 Attendee

TM ETRS-TM35FIN-ETRS89 WTG

7.4 Variability management

LYTH-CONS CONSISTENCY TRANSMITTER

TM ETRS-TM35FIN-ETRS89 WTG

WindPRO version joulu 2012 Printed/Page :42 / 1. SHADOW - Main Result

MIGS videoendoskooppi

Tynnyrivaara, OX2 Tuulivoimahanke. ( Layout 9 x N131 x HH145. Rakennukset Asuinrakennus Lomarakennus 9 x N131 x HH145 Varjostus 1 h/a 8 h/a 20 h/a

TM ETRS-TM35FIN-ETRS89 WTG

Q = pienin suunniteltu ilmamäärä ja k = puhaltimen tai iirispellin k-arvo.

TM ETRS-TM35FIN-ETRS89 WTG

( ,5 1 1,5 2 km

TM ETRS-TM35FIN-ETRS89 WTG

FYSE301(Elektroniikka(1(A3osa,(kevät(2013(

( ( OX2 Perkkiö. Rakennuskanta. Varjostus. 9 x N131 x HH145

,0 Yes ,0 120, ,8

TIEKE Verkottaja Service Tools for electronic data interchange utilizers. Heikki Laaksamo

Salasanan vaihto uuteen / How to change password

AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY GRANT4COM OY

Rekisteröiminen - FAQ

Optimus äänitasomittari Käyttöohje

TM ETRS-TM35FIN-ETRS89 WTG

You can check above like this: Start->Control Panel->Programs->find if Microsoft Lync or Microsoft Lync Attendeed is listed

TM ETRS-TM35FIN-ETRS89 WTG

SafeLine VA4 Käyttöohjeet

AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY VERKOTAN OY VERKOTAN LTD.

KÄYTTÖOHJE PEL 1000 / PEL 1000-M

Särmäystyökalut kuvasto Press brake tools catalogue

FinFamily PostgreSQL installation ( ) FinFamily PostgreSQL

Rakennukset Varjostus "real case" h/a 0,5 1,5

TM ETRS-TM35FIN-ETRS89 WTG

Technische Daten Technical data Tekniset tiedot Hawker perfect plus

Security server v6 installation requirements

AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY

AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY

performance DHW coil type exchanger Diverter valve Analogue thermostat control panel Heating pump DHW pump Digital electronic control panel

Security server v6 installation requirements

Mitat. Tuotekoodi. Materiaalit ja pintakäsittely. lindab kattolaittet. GS23 liitäntälaatikolla H. GS23 yläosalla V

SwemaFlow 125D ilmanvirtausmittari

Fluke-VR1710. Pikakäyttöopas. Häiriöjännitetallennin. Tämä opas on vain ohjeellinen. Tarkemmat ohjeet löydät englanninkielisestä User Manual-ohjeesta

Sisällysluettelo Table of contents

SpeechMike III sarjan sanelumikrofonien (mallit LFH3200 ja LFH3220) yhteensopivuus SpeechMagic Executive saneluohjelman kanssa

Sisäilman laatu mittarit

Innovative and responsible public procurement Urban Agenda kumppanuusryhmä. public-procurement

Lab SBS3.FARM_Hyper-V - Navigating a SharePoint site

AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY

Air Comfort. VEKA ver C.» Spare parts/reservdelar/varaosat

Yhtiön nimi: - Luotu: - Puhelin: - Fax: - Päiväys: -


G INSTRUCTIONS FOR USE BRUGSANVISNING BETRIEBSANLEITUNG VC300 SERIES USER MANUAL MODE D EMPLOI INSTRUCCIONES DE USO

The CCR Model and Production Correspondence

Voice Over LTE (VoLTE) By Miikka Poikselkä;Harri Holma;Jukka Hongisto

National Building Code of Finland, Part D1, Building Water Supply and Sewerage Systems, Regulations and guidelines 2007

SSTY:n EMC-seminaari. EMC ja sähköisten lääkintälaitteiden standardit. Ari Honkala SESKO ry

( N117 x HH141 ( Honkajoki N117 x 9 x HH120 tv-alueet ( ( ( ( ( ( ( ( ( ( m. Honkajoki & Kankaanpää tuulivoimahankkeet

GPRS-lisäpalvelu INTERNET-ASETUKSET

Väylämoduuli - DALI Master Wago

Efficiency change over time

Information on preparing Presentation

1. SIT. The handler and dog stop with the dog sitting at heel. When the dog is sitting, the handler cues the dog to heel forward.

Uuden sukupolven äänitasomittarisarja

VTT EXPERT SERVICES OY

Declaration of performance/ Suoritustasoilmoitus

Käytön avoimuus ja datanhallintasuunnitelma. Open access and data policy. Teppo Häyrynen Tiedeasiantuntija / Science Adviser

Samurai helppokäyttöinen ohjelma melun ja värähtelyjen mittauksiin

RULLARADAT RULLADAT ROLLER TABLES

Äänitason mittarit tuoteseloste

SELL Student Games kansainvälinen opiskelijaurheilutapahtuma

OP1. PreDP StudyPlan

31, 30/12V, 41, SW

Other approaches to restrict multipliers

Reliable sensors for industrial internet

Secto Design Oy Kauppalantie Kauniainen Finland tel fax info@sectodesign.fi

Studioiden vaativaan työympäristöön suunniteltu aktiivikaiutinsarja. Pro Studio 30, 40, 55, 65, 80 ja 100 SW mallit

Gap-filling methods for CH 4 data

03 PYÖRIEN SIIRTÄMINEN

Results on the new polydrug use questions in the Finnish TDI data

C++11 seminaari, kevät Johannes Koskinen

Hankintailmoitus: Pohjois-Savon sairaanhoitopiirin kuntayhtymä/kiinteistöyksikkö : Puijon sairaalan Pääaula-alueen uudistus, Sähköurakka

Returns to Scale II. S ysteemianalyysin. Laboratorio. Esitelmä 8 Timo Salminen. Teknillinen korkeakoulu

HITSAUKSEN TUOTTAVUUSRATKAISUT

Kuvakkeet asiaankuuluvien tietoluokkien esittämiseksi Yhteentoimivuus. Elinkeinonharjoittajan nimi. Internet-yhteys. Maantieteelliset rajoitukset

JABRA. Juha Pieviläinen Channel Account Manager - Finland

LUONNOS RT EN AGREEMENT ON BUILDING WORKS 1 THE PARTIES. May (10)

Teknologiateollisuus ry Ympäristöosaaminen arvoketjussa -seminaari Työkaluja arvoketjun ympäristöosaamisen kehittämiseen

Network to Get Work. Tehtäviä opiskelijoille Assignments for students.

HARJOITUS- PAKETTI A

On instrument costs in decentralized macroeconomic decision making (Helsingin Kauppakorkeakoulun julkaisuja ; D-31)

Alternative DEA Models

Transkriptio:

Äänitasomittarit Äänitasomittari luokka 2 CR:262A 26..140db,integroiva. ilmanvaihdon melun mittaukseen. Käyttökohteita Ilmanvaihdon äänitason mittari Laitemelun mittari Ajoneuvomelun testaus Työperäisenmelun mittaus Viihdemelun mittaus Konserttien melumittaus Tuotantolinjojen melutestaus Laadun tarkkailu Äänen tehon mittaus Hälytysäänen testaus Tärkeimmät ominaisuudet: Yksinkertainen käyttää yhden toiminnon näppäimillä Integrointimittaus vakiona(leq) Normien IEC616 7 2, IEC60651 ja IEC60804 mukainen Automaattinen tiedontallennus "+" malleilla(esim. 26 2A) Mittausalue 26..140 db(a) (CR 26 2 ja CR264 malleilla) Käyttäjän valittavissa A ja C painoitus HML mittausta ja konemelua varten kaikissa äänitason mittari versioissa USBliitäntä mahdollistaa äänitason tallennuksen suoraan tietokoneelle("+" versiot) Äänitasomittari CR262A soveltuu erityisesti ilmanvaihdon mittauksiin. CR 26 2A Luokka 2 mittari soveltuu ilmanvaihdon äänimittauksiin, joissa vaaditaan 28 db tason mittauksia. Luokka 2 mittarit ovat kehittyneet riittävään herkkyyten, jolla voidaan mitata jopa näin pieniä äänenpaineita. Mittaria käyttäviä ammattiryhmiä voivat olla Esimerkiksi LVI-asentajat tai konemeluntestaajat. "+" version päivitys Kaikki CR 260 äänitasomittarit voidaan päivittää "+" versioon, jos ei ole ostanut sellaista. "+" versio tuo mittariin tiedontallennuksen. Yksilöllinen avain Pietiko Oy Tykistökatu 4 B 310(ElektroCity) 20520 Turku, puh (02) 2514402, fax (02) 2510015 www.pietiko.fi

Äänitasomittarit vaaditaan mittarin lukituksen avaamiseen. joka avaa seuraavat pääominaisuudet mittariin: 100 mittaustuloksen taltiointi sekunnin aikahistorialla, tallennettujen tietojen lataus tietokoneelle Deaf Defier ohjelmalla, käyttäjän valittavissa oleva taajuuspainoitus (A, C tai Z) aika painoitus (F, S tai I), Mittaustapa Ln tasot äänen altistus tasot (Lae). CR260 Äänitasomittari/melumittari sarja pitää sisällään monipuolisia ominaisuuksia mittauksiin. Laite on kuitenkin tehty erittäin helppokäyttöiseksi yhden toiminnon näppäimillä. Näppäimissä on selkeät merkinnät mitä niistä tapahtuu. Äänitasomittari/melumittari kuitenkin täyttää alan viimeisimmät standardit äänitason mittauksesta. Mittariin on valmiiksi tehty tarvittavat asetukset mittauksia varten, joten monimutkaista menu valikkoa ei löydy. Mittari mittaa kaistamittauksessa seuraavat: Äänitason Lxf(ei tallenneta), Lxeq integroidun keskiarvoäänitason, Lxfmax maksimiäänitason nopea aikapainoitus, Lxfmin minimiäänitason nopea aikapainoitus, Lcpeak äänitaso piikki. Mittauksessa käyttäjä valitsee "x":n paikalle taajuuspainoitus A tai C (esim Lcmax). + versio mittaa lisäksi kaistamittauksessa: Lxe Lxleq tai Lxfteq, Lxn (0,1-99,9) viisi samanaikaista lukua, kellonaika ja päivämäärä, Lxeq lyhyt aika historia. X = db(a), db(c) tai db(z) taajuuspainoitusta. Y = nopea(f), hidas(s), tai impulssi(i) aikapainoitusta. + versio mittaa lisäksi oktaavitaajuusmittauksessa valitulla taajuudella : kellonaika ja päivämäärä mittauksesta. + versio tallentaa lyhyen Leq aikahistorian sekunnin välein 24h asti. On mahdollista valita seuraavia aikatallennusmuotoja 1min, 5min, 10min, 15min, 30min, 1h, 8h ja 12h. Lisäksi käyttäjän on mahdollista asettaa omat tallennusajat. On myös mahdollista tallentaa taukojen kanssa. Pietiko Oy Tykistökatu 4 B 310(ElektroCity) 20520 Turku, puh (02) 2514402, fax (02) 2510015 www.pietiko.fi

Cirrus Research plc dedicated to noise measurement CR:260A Sound Level Meters

Key Features Simple operation with single function buttons Introduction The CR:260A Series of Sound Level Meters are suitable for a wide range of applications. From Noise at Work Risk Assessments to Vehicle Noise Testing to Environmental Noise Measurements, the CR:260A Series provides a solution. The instruments have been designed to be extremely simple to use while meeting the latest Standards for Sound Level Meters. Available with Class 1 or Class 2 accuracy along with the options of Octave Band Filters and a Data Logging upgrade, there is an instrument to meet your noise measurement needs. Reliable, accurate and affordable, the CR:260A Series are the ideal instruments for your noise measurement applications. CR:260A Complies with the latest IEC 61672 standard as well as IEC 60651 and IEC 60804 for compliance with virtually all noise measurement regulations Available with Class 1 or Class 2 accuracy User selectable A & C Weighting for HML measurements & machinery noise testing on all versions Octave Band Frequency Analysis (CR:264A & CR:263A) to help in the selection of hearing protection (PPE) +Version upgrade adds Data Logging, the ability to download measurements to a PC and additional noise measurement functions such as L 10, L 90 and L AE (SEL) USB connection for simple downloading of data with the +Version upgrade CR:261S Sound Level Meter available for Vehicle Noise Testing to ISO 5130:1982 & 29 StVZO with PTB Type Approval - Please refer to the CK:261S Datasheet for further information 2 Year standard warranty with 10 year extended warranty giving you up to 12 years of cover CR:262A CR:262A+ CR:261 CR:261+ CR:264 CR:264+ CR:263 CR:263+ Instrument Selection Class 1 Class 2 L Aeq Peak(C) 1:1 Octave Band Filters Software Support

Applications Occupational Noise Measurement Simultaneous measurement of L AF, L Aeq, L AFmax and L Cpeak Time history of noise levels User selectable A or C weighting Risk Assessment of Workplace Noise Levels Measurements for the selection of hearing protection with CR:264A & CR:263A using Octave Band Filters Calculate Noise Exposures with the Deaf Defier Software and create measurement reports (+Version) Environmental Noise Measurement Boundary noise measurements External noise impact assessments Machinery noise testing Motorsport noise measurements Entertainment noise Time History reports with the +Version Upgrade General Noise Measurements R&D noise measurements Production line noise testing Quality control Sound power measurements Fire alarm testing +Version Data Logging Upgrade All of the CR:260A Sound Level Meters can be upgraded to the +Version, which unlocks the additional functions of the instrument. The main features of the +Version are: Up to 100 Measurements stored in memory with 1 second Time History Download Measurements to a PC and the Deaf Defier 3 Software User selectable Frequency Weighting (A, C or Z) & Time Weighting (F,S or I) Measurement of L n levels & Sound Exposure Levels (L AE ) To upgrade to the +Version, a unique upgrade key is required to unlock the extra functions of the instrument. Deaf Defier3 allows measurements to be presented as reports and all of the parameters viewed for analysis. In addition, the configuration of the instrument which can be changed as required. Please visit the Cirrus website for more information. Measurement Kits All versions of the CR:260A Series can be supplied as complete measurement kits. The kit includes the following parts: CR:260A Series Sound Level Meter CR:514 or CR:515 Acoustic Calibrator UA:237 Windshield CK:250 Carrying Case User Manuals, Certificates of Calibration & Batteries All CR:260A instruments are supplied with a Software CD and USB download cable. This allows the user to upgrade their instrument to the +Version by simply connecting it to the Deaf Defier3 software and entering a license key. Ordering Information Instrument Only: CR:262A Class 2 Sound Level Meter CR:261A Class 1 Sound Level Meter CR:264A Class 2 Sound Level Meter with 1:1 Octave Band Filters CR:263A Class 1 Sound Level Meter with 1:1 Octave Band Filters Measurement Kits CK:262A Class 2 Sound Level Meter Measurement Kit CK:261A Class 1 Sound Level Meter Measurement Kit CK:264A Class 2 Sound Level Meter Measurement Kit with 1:1 Octave Band Filters CK:263A Class 1 Sound Level Meter Measurement Kit with 1:1 Octave Band Filters +Version Data Logging Upgrade UP:260/1Upgrade to +Version with Data Logging Other options and accessories may be available for the CR:260A Series. Please contact Cirrus Research plc or your local representative for a full list of the options and accessories available. The Deaf Defier3 Software is supplied with no licensing restrictions. Updates can be downloaded from the Cirrus Research plc website. All Cirrus Research plc Sound Level Meters, Noise Dosemeters and Acoustic Calibrators are supplied with a standard 2 year warranty and an optional extendable 10 year warranty.

Specifications Applicable Standards IEC 61672-1:2002 Class 1 or 2 Group X IEC 60651:2001 Type 1 I or Type 2 I IEC 60804:2000 Type 1 or Type 2 ANSI S1.4 with NK:70 Random Incidence Adaptor Fitted 1:1 Band Filters to IEC 61260 Class 1 (where fitted) Microphone Class+ Pre-polarized Free-field 1/2" Condenser Random Incidence to ANSI S1.4 with NK:70 Adaptor Microphone Preamplifier Class 1 Instruments MV:200D Removable Preamplifier, Class 2 Instruments MV:200D Integral Preamplifier Time Weightings 'F' (Fast) to IEC 61672-1:2002 Class 1 or 2 + Version also provides 'S' (Slow) & 'I' (Impulse) to IEC 61672-1:2002 Class 1 or 2 Frequency Weightings Channel 1 - User selectable A or C weighting, Channel 2 'C' for Peak + Version also provides A, C or Z for Channel 1, Channel 2 'C' for Peak Frequency Bands Nominal Frequencies (CR:264A & CR:263A only) 1:1 Octave Band Filters - 31Hz to 16kHz Measurement Range (Typical) Broadband 24dB(A) to 140dB(A) Class 1, 26dB(A) to 140dB(A) Class 2 143dB(C) Peak (70 to 140dB Range) 1:1 Octave Bands 15dB to 140dB (1kHz 1:1 Octave Band) Noise Floor (Typical) Broadband 21dB(A) Class 1, 23dB(A) Class 2 1:1 Octave Band Filters 15dB(Z) @ 1kHz 1:1 Octave Band Display Graphical LCD with Quasi-Analogue Display Selected measurement parameter with level Warnings for Overload, Under Range & Battery Level Time & Frequency Weighting Elapsed measurement time Real time short Leq (broadband mode) Graphical 1:1 Octave Bands Recalled Last Measurements Measurement Range Instrument settings Measurement Storage The last measurement is stored. + Version also provides 100 broadband or 1:1 Octave Band measurements Short L eq Time History: Up to 24 hours at 1 second Automatic Measurements (+ Version Only) The unit can be set to record and store data over fixed times of: 1 minute 5 minutes 10 minutes 15 minutes 30 minutes 1 hour 8 hours 12 hours or a user defined period Available Measurements Broadband Mode: L XF Sound Level (Not Stored), Fast Time Weighting L Xeq Equivalent Continuous Sound Level L XFmax Maximum Sound Level, Fast Time Weighting L XFmin Minimum Sound Level, Fast Time Weighting L Cpeak Peak Sound Pressure, db(c) Measurement Duration Where X = Frequency Weighting or A or C (User Selectable) 1:1 Octave Band Mode: Selected Frequency, Filtered L ZF (Not stored), db(z), Fast Time Weighting Filtered L Zeq Equivalent Sound Level for each Octave Band L Aeq,L Ceq & L Zeq Equivalent Sound Level Measurement Duration + Version allows the following measurements to be made Broadband Mode: L XY Sound Level (Not Stored) L Xeq Equivalent Continuous Sound Level L XY max Maximum Sound Level L XY min Minimum Sound Level L Cpeak Peak Sound Level L XE, L XIeq or L XFTeq L Xn (0.1 to 99.9) Five Simultaneous values Date & Time of measurement Where L Xeq Short Leq Time History X= db(a), db(c) or db(z) Frequency Weighting. Y = Fast(F), Slow(S) or Impulse(I) Time Weighting 1:1 Octave Band Mode: Selected Frequency Filtered L ZF (Not stored), db(z), Fast Time Weighting Filtered L Zeq Equivalent Sound Level L Aeq,L Ceq &L Zeq Equivalent Sound Level Measurement Duration Date & Time of Measurement Physical Dimensions Weight Power Battery Life 340mm x 75mm x 25mm 450 gms 2 x 1.5v Alkaline LR6/AA Broadband Mode Typically 24 hours 1:1 Octave Band Mode Typically 12 hours Environmental Temperature Operating -10 C to +50 C Storage -20 C to +60 C Humidity Up to 95% RH Non Condensing Electromagnetic Performance IEC 61672-1:2002 IEC 61672-2:2003 Except where modified be EN 61000-6-1:2007 & EN 61000-6-1:2007 External Connections USB Type B for Data Connection (available for + Version only) Output Cables (+ Version Only) Standard: ZL:100 USB Cable Software Support (+ Version Only) Deaf Defier3 for Windows. (Version v3.2.0 or later) The Deaf Defier3 for Windows requires Microsoft Windows 98SE or later Cirrus Research plc dedicated to noise measurement Acoustic House, Bridlington Road Hunmanby, North Yorkshire, YO14 0PH United Kingdom Tel: 0845 23 0 2434 (Local Rate UK Only) +44 (0) 1723 891655 Fax: +44 (0) 1723 891742 Email: sales@cirrusresearch.co.uk Web: www.cirrusresearch.co.uk Your Cirrus Distributor Cirrus Research plc. E&OE CR:260A/03/08/01r1