MONTERINGSANVISNING VÄXELVENTIL, KYLA VCC 28 TILL HBS 16 INSTALLATION INSTRUCTIONS SHUTTLE VALVE, COOLING VCC 28 FOR HBS 16



Samankaltaiset tiedostot
MONTERINGSANVISNING VÄXELVENTIL, KYLA VCC 22 TILL NIBE SPLIT INSTALLATION INSTRUCTIONS SHUTTLE VALVE, COOLING VCC 22 FOR NIBE SPLIT

ASENNUS- JA KÄYTTÖOHJEET MOS FI HK: 150/200/ HK 150, 200, 300 LEK

F2015/F2016/F2025/F2026/F2030/F2300

Käyttöohjekirja NIBE SAM 40

Asentajan käsikirja AHP/AHPS

Asentajan käsikirja VPB/VPBS. Lämminvesivaraaja IHB FI LEK

ELK ELK 26 LEK

MOS FI HK: ASENNUS- JA HOITO-OHJEET HK 15 ASENNUS- JA HOITO-OHJE, RUOSTUMATTOMILLE LÄMMINVESIVARAAJILLE

MONTERINGSANVISNING EXTRA SHUNT ESV 22 TILL NIBE SPLIT INSTALLATION INSTRUCTIONS EXTRA SHUNT ESV 22 FOR NIBE SPLIT

ETS 12 / 121. Huom! Huom! Komponenttiluettelo. Yleistä. Komponentit. Varatila

INSTALLATION INSTRUCTIONS EXTRA SHUNT ESV 28 FOR HBS 16 MONTAGEANLEITUNG EXTRA MISCHGRUPPE ESV 28 FÜR HBS 16

ASENNUS- JA KÄYTTÖOHJEET MOS FI HK: 150/200/ HK 150, 200, 300 LEK

Käyttöohjekirja NIBE SAM 41

ELK ELK 42 LEK

MOS FI ASENNUS- JA HOITO-OHJEET ELK ELK 26 LEK

MOS FI HK: ASENNUS- JA HOITO-OHJEET HK 15 ASENNUS- JA HOITO-OHJE, RUOSTUMATTOMILLE LÄMMINVESIVARAAJILLE

Asentajan käsikirja VPB 200. Varaajasäiliö IHB FI LEK

MOS SE ER57-R 300 Finland MONTERINGS- OCH SKÖTSELANVISNING COMPACT R 300. MONTERINGS- OCH SKÖTSELANVISNING Compact

Käyttö- ja asennusohje NIBE UKV 20

Asentajan käsikirja AHP/AHPS

Käyttöohjekirja NIBE SMO 20. Ohjausyksikkö UHB FI LEK

Asentajan käsikirja VPB 200/VPB 300. Lämminvesivaraaja IHB FI LEK

Käyttöohjekirja NIBE VVM 320. Sisäyksikkö UHB FI APH

MOS FI VEDEX ASENNUS- JA HOITO-OHJEET VEDEX 3300 LEK

Asentajan käsikirja SMO 40

Käyttöohjekirja NIBE F370

Käyttöohjekirja NIBE F , 12, 16 kw Ilma/vesi-lämpöpumppu UHB FI LEK LEK LEK

Asentajan käsikirja VPB/VPBS

Käyttöohjekirja NIBE SMO 40

Asentajan käsikirja. SE-PV 3031 Aurinkokennopaketti. Lisätarvikkeet IHB FI

SIRIUS valaisin on asemoitava siten, ettei pitkäaikaista katsomista valaisimeen voi olettaa tapahtuvan 2,3m lähempää.

Käyttö- ja asennusohje VPB/VPBS

Käyttöohjekirja NIBE F1155

Käyttöohjekirja NIBE F2026

Käyttöohjekirja NIBE F2040

Käyttöohjekirja NIBE SPLIT HBS 05 AMS 10-8 / / 10-16, HBS / 05-16

Käyttöohjekirja HBS 05 HBS 05-6 / / 05-16

KVR 10. Installatörshandbok Kondensvattenrör KVR 10. Installer manual Kondensvattenrör KVR 10. Installateurhandbuch Kondensvattenrör KVR 10

Käyttöohjekirja AMS 10 AMS 10-6 / 10-8 / / 10-16

Asentajan käsikirja SAM 40. Tuloilmamoduuli IHB FI LEK

Asentajan käsikirja NIBE F1226. Maalämpöpumppu IHB FI LEK

NIBE F1155/F1255. Elschema. Wiring diagram. Elektrischer Schaltplan IHB SE

Asentajan käsikirja PV-aurinkokennopaketti

MOS FI FJVM ASENNUS- JA HOITO-OHJEET FJVM 120 FIGHTER 310P/360P LEK

Asentajan käsikirja NIBE VVM 320

Asentajan käsikirja SAM 40. Tuloilmamoduuli IHB FI LEK

LEK EXC 40. Installatörshandbok EXC 40. Installer manual EXC 40. Installateurhandbuch EXC 40. Asentajan käsikirja EXC 40 IHB

Käyttöohjekirja F2040 6, 8, 12, 16

Käyttöohjekirja NIBE F110

Nibette 15 SE FI. Cu 15. Användar- och installatörshandbok Nibette 15. Käyttö- ja asennusohje Nibette 15 CHB

Asentajan käsikirja NIBE F1226. Maalämpöpumppu IHB FI LEK

Käyttöohjekirja NIBE F2120 8, 12, 16, 20

Asentajan käsikirja NIBE VVM 500

RTS 40 IHB

Alfa Q TW 56W Alfa Q 58W GLAQTW00056 GLAQ W 58 W 5300 lm 5400 lm

Asentajan käsikirja PV-aurinkokennopaketti

Asentajan käsikirja SAM 40. Tuloilmamoduuli IHB FI LEK

Käyttöohjekirja NIBE F2030. Ilma/vesi-lämpöpumppu UHB FI LEK

ER57-R 300 Finland COMPACT R 300

COMPACT-R: 300 MOS SE/FI ER 56: MONTERINGS- OCH SKÖTSELANVISNING, ROSTFRI VARMVATTENBEREDARE

Asentajan käsikirja NIBE F1245. Maalämpöpumppu IHB FI LEK

Käyttöohjekirja NIBE F2120 8, 12, 16, 20

SQUARE. Greenled Tarjusojantie Kempele FINLAND

Asentajan käsikirja NIBE F470

Käyttöohjekirja NIBE SMO 05

ASENNUSOHJE KÄYTTÖVEDEN LÄMMITYKSEN OHJAUS VST 114/VST 200 MONTERINGSANVISNING VARMVATTENSTYRNING VST 114/VST 200

TRIMFENA Ultra Fin FX

MOS FI ASENNUS- JA HOITO-OHJEET VEDEX 1000 VEDEX 1000 LEK

Asentajan käsikirja NIBE F750. Poistoilmalämpöpumppu IHB FI LEK

Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Muutokset sallittu vain sertifikaatin my

I-VALO LED 6721 RETROFIT instructions

Changes in the drawing are allowed only by the permission of the authorities who have granted the certificate Muutokset sallittu vain sertifikaatin my

COMPACT-E: 200, 300 MOS COMPACT-E: 200, 300 MONTERINGS- OCH SKÖTSELANVISNING ASENNUS- JA HOITO-OHJE LEK

Eminent SE GB FI NL. E/Cu/R 35, 55, 100, 120. Användar- och installatörshandbok Eminent. User and installer manual Eminent

Asentajan käsikirja PV-aurinkokennopaketti

DESIGN NEWS MATTI MÄKINEN EIN DESIGNER IN ANGEBOT WIE LOCKEN WIR DEN GEIST IN DIE FLASCHE?

Asentajan käsikirja NIBE F2030. Ilma/vesi-lämpöpumppu IHB FI LEK

Käyttöohjekirja NIBE F2300

MONTERINGS- OCH SKÖTSELANVISNING Kopparfodrad varmvattenberedare. ASENNUS- JA HOITO-OHJEET Kuparivuorattu lämminvesivaraaja

SIRIUS valaisin on asemoitava siten, ettei pitkäaikaista katsomista valaisimeen voi olettaa tapahtuvan 2,3m lähempää.

SIGMA 77W SIGMA 117W SIGMA 155W SIGMA 235W GLSI00077 GLSI00117 GLSI00155 GLSI W 117 W 155 W 235 W lm lm lm lm

FJVM FIGHTER 310P/410P/360P

GAMMA. Greenled Oy Tarjusojantie FI Kempele, Finland

You can check above like this: Start->Control Panel->Programs->find if Microsoft Lync or Microsoft Lync Attendeed is listed

SIRIUS valaisin on asemoitava siten, ettei pitkäaikaista katsomista valaisimeen voi olettaa tapahtuvan DIM * lähempää.

LEK LEK ECS 40/ECS 41

Asennusohje EKC 367. Periaate Principle Montageprinzip Principe. Mitat Dimensions Maße Dimensions

ECO S. Greenled Oy Tarjusojantie FI Kempele, Finland

Elektronisk Scart-växel SCART-kytkin äänelle ja kuvalle. KÄYTTÖOHJE BRUKSANVISNINGVers:

Installation instruction PEM

ECO E II. Greenled Tarjusojantie Kempele FINLAND

Fonte 16045SAVA 16045VAVA 16045SAVA 16045VAVA ASENNUSOHJE MONTERINGSANVISNING ASSEMBLY INSTRUCTIONS K16045VAK2 K16045SAK1 K16045K3 K16045K3

kovalla, valkoisella istuinkannella nro , min.100

FinFamily PostgreSQL installation ( ) FinFamily PostgreSQL

TSL-peilikaappi TSL-spegelskåp. TST-peilikaappi TST-spegelskåp. Asennusohje Monteringsanvisning

MOS FI FIGHTER ASENNUS- JA HUOLTO-OHJEET NIBE FIGHTER 2020 LEK

Z-N626 LAITTEEN PIKAOPAS

EMK 300. Energimätarkit EMK 300. Energy meter kit EMK 300. Energimesssatz EMK 300. Energimålersæt EMK 300. Energiamittarisarja EMK 300

ÜB. 1. der Fuβ der Kopf das Knie der Bauch die Schulter das Auge der Mund. jalka pää polvi vatsa hartia, olkapää silmä suu

Thermozone AD 102/103

Transkriptio:

MAV 1213-2 031954 SE MONTERINGSANVISNING VÄXELVENTIL, KYLA TILL HBS 16 GB INSTALLATION INSTRUCTIONS SHUTTLE VALVE, COOLING FOR HBS 16 DE FI MONTAGEANLEITUNG WECHSELVENTIL, KÜHLUNG FÜR HBS 16 ASENNUSOHJE JÄÄHDYTYKSEN VAIHTOVENTTIILILLE KÄYTETTÄVÄKSI HBS 16 KANSSA LEK

MONTERINGSANVISNING SE Allmänt Innehåll Detta tillbehör används då NIBE SPLIT:s innemodul HBS 16 installeras i hus med kyl- och värmesystem, t.ex. då huset har både radiatorsystem och fläktkonvektorer. OBS! Detta tillbehör kräver tillbehöret ACK 28 för installation i HBS 16. 3st 3st 3st 1st 1st Kopparrör, kragat Planpackning Unionsmutter 1 1/4" 3-vägsventil Reglermotor, EP22-QN12 3

SE Röranslutning HBS 16 Montering sker enligt följande: Töm först pannvattenkärlet/värmesystemet om detta är vattenfyllt. Shuntventilen (EP22-QN12) placeras på framledningen efter HBS 16, före första radiator på värmesystem 1, se bild. se bild. OBS! Vid felaktig montering kan funktionen äventyras. Shuntventil, (EP22-QN12) Anslutningar, Ø 28 mm Värme HBS 16 LEK Kyla Kvs-värde 8,5 4

SE Principschema HBS 16 med - växelventil, kyla EP22-QN12 Kyla A B AB RG10/ RE10 CP1 Överströmnings- Överströmningsventil Erf. säkerhetsutr. Erforderlig säkerhetsutr. FQ1 FL1 BT 1 HBS AMS HEV Förklaring BT1 Temperaturgivare, utomhus CP1 Utjämningskärl UKV EP22-QN12 Växelventil (Kyla/värme) 5

SE Elinkoppling HBS 16 Programinställningar OBS! All elektrisk inkoppling skall ske av behörig elektriker. Elektrisk installation och ledningsdragning skall utföras enligt gällande bestämmelser. HBS 16 ska vara spänningslös vid installation av VCC 28. Välj Service i meny 8.1.1 för att få tillgång till meny 9.0 och dess undermenyer. Välj sedan Till i meny 9.3.3, Kylsystem. I meny 8.2.4 och 8.2.5 görs inställningar för start och stopp av kyla. I undermenyerna till meny 2.2.0 görs övriga kylinställningar som t.ex. val av kylkurva. Se också Monterings- och skötselanvisning för NIBE SPLIT. Elscheman finns i slutet av denna monteringsanvisning. Elkoppling, X6 LEK Elkoppling, X6 8 Blå 7 6 5 4 Brun 3 2 Vit 1 1. Tillbehöret ACK 28 installeras enligt medförljande monteringsanvisning. 2. Ventilställdonet EP22-QN12 anslutes enligt följande: - Brun ledare (230 V signal) till fjäderplinten X6:3a - Vit ledare (230 V signal) till fjäderplinten X6:1a - Blå ledare (nolla) till fjäderplinten X6:6a 6

INSTALLATION INSTRUCTIONS GB General Contents This accessory is used when the indoor module HBS 16 in NIBE SPLIT is installed in houses with cooling and heating systems, for example, in cases where the house has a radiator system and fan convectors. NOTE This accessory requires accessory ACK 28 for installation in HBS 16. 3x 3x 3x 1x 1x Copper pipe, collared Flat gasket Swivel nut 1 1/4" 3-way valve Control motor, EP22-QN12 7

GB Pipe connections HBS 16 Install as follows: First drain the boiler water reservoir/heating system if filled with water. The shunt valve (EP22-QN12) is located on the flow line after HBS 16, before the first radiator in the heating system 1, see image. see image. NOTE Incorrect installation can affect the function. By-pass valve, (EP22-QN12) Connections, Ø 28 mm Heating HBS 16 LEK Cooling KVS value 8,5 8

GB Outline diagramhbs 16 with - three-way valve, cooling EP22-QN12 Cooling Kyla A B AB RG10/ RE10 CP1 Överströmningsventil valve Bypass Required safety Erf. säkerhetsutr. equipment FQ1 FL1 BT 1 HBS AMS HEV Explanation BT1 Temperature sensor, outdoor CP1 Buffer vessel UKV EP22-QN12 Three way valve (Cooling/heating) 9

GB Electrical connection HBS 16 - Blue cable (zero) to spring terminal X6:6a NOTE All electrical connections must be carried out by an authorised electrician. Electrical installation and wiring must be carried out in accordance with the stipulations in force. HBS 16 must not be powered when installing. The electrical circuit diagram is at the end of these installation instructions. Program settings Select Service in menu 8.1.1 to gain access to menus 9.0 and the sub-menus. Select On in menu 9.3.3, Cooling system. Settings are made for cooling start and stop in menu 8.2.4 and 8.2.5. In the sub menus for menu 2.2.0 other cooling settings are made, e.g. cooling curve selection. See Installation and Maintenance Instructions for NIBE SPLIT. Electrical connection, X6 LEK Electrical connection, X6 8 Blue 7 6 5 4 Brown 3 2 White 1 1. The accessory ACK 28 is installed according to the supplied installation instructions. 2. Connect valve actuator EP22-QN12 as follows: - Brown cable (230 V signal) to spring terminal X6:3a - White cable (230 V signal) to spring terminal X6:1a 10

MONTAGEANLEITUNG DE Allgemeines Dieses Zubehör kommt zum Einsatz, wenn das NIBE SPLIT- Innenmodul HBS 16 in einem Haus mit Kühl- und Heizkreis installiert ist, z.b. wenn ein Gebäude über ein System mit Heizkörpern und Gebläsekonvektoren verfügt. HINWEIS! Dieses Zubehör erfordert das Zubehör ACK 28 für die Installation in HBS 16. Inhalt 3St. 3St. 3St. 1St. 1St. Kupferrohr, mit Flansch Flachdichtung Überwurfmutter 1 1/4" 3-Wegeventil Stellantrieb, EP22-QN12 11

DE Rohranschluss HBS 16 Führen Sie die Montage wie folgt durch: Entleeren Sie zuerst das Wasser aus dem Heizwassergefäß/Heizkreis. Bringen Sie das Mischventil (EP22-QN12) am Vorlauf nach HBS 16 und vor dem ersten Heizkörper für Heizkreis 1 an, siehe Abbildung. an, siehe Abbildung. HINWEIS! Bei einer falschen Montage kann die Funktionsweise beeinträchtigt werden. Mischventil, (EP22-QN12) Anschlüsse, Ø 28 mm Wärme HBS 16 LEK Kühlung KVS-Wert 8,5 12

DE Prinzipskizze HBS 16 mit Umschaltventil, Kühlung EP22-QN12 Kühlung Kyla A B AB RG10/ RE10 CP1 Överströmnings- Überströmventil Erforderliche Erf. säkerhetsutr. Sicherheitsausr. FQ1 FL1 BT 1 HBS AMS HEV Erklärung BT1 Außentemperaturfühler CP1 Pufferspeicher UKV EP22-QN12 Umschaltventil (Kühlung/Heizung) 13

DE Elektrischer Anschluss HBS 16 HINWEIS! Alle elektrischen Anschlüsse müssen von einem befugten Elektriker ausgeführt werden. Bei der Elektroinstallation und beim Verlegen der Leitungen sind die geltenden Vorschriften zu berücksichtigen. HBS 16 darf bei der Installation von nicht mit Spannung versorgt werden. Der Schaltplan befindet sich am Ende dieser Montageanleitung. - Brauner Leiter (230-V-Signal) mit Federklemme X6:3a - Weißer Leiter (230-V-Signal) an Federklemme X6:1a - Blauer Leiter (Nullleiter) an Federklemme X6:6a. Programmeinstellungen Durch Auswahl von "Service" in Menü 8.1.1 erhalten Sie Zugriff auf Menü 9.0 und die zugehörigen Untermenüs. Wählen Sie anschließend "Ein" im Menü 9.3.3, "Kühlsystem" aus. In Menü 8.2.4 und 8.2.5 werden Einstellungen für Kühlstart und Kühlstopp vorgenommen. In den Untermenüs zu Menü 2.2.0 werden die weiteren Kühleinstellungen vorgenommen, z.b. Auswahl der Kühlkurve. Siehe auch "Montage- und Wartungsanleitung" für NIBE SPLIT. Elektrischer Anschluss, X6 LEK Elektrischer Anschluss, X6 8 Blau 7 6 5 4 Braun 3 2 Weiß 1 1. Das Zubehör ACK 28 wird gemäß der beiliegenden Montageanleitung installiert. 2. Ventilstellvorrichtung EP22-QN12 wird wie folgt angeschlossen: 14

ASENNUSOHJE FI Yleistä Tätä lisävarustetta käytetään, kun NIBE SPLIT -sisäyksikkö HBS 16 asennetaan taloon, jossa on lämmitys- ja jäähdytysjärjestelmä, esim. kun talossa on sekä patterijärjestelmä että puhallinkonvektorit. HUOM! Tämä lisävaruste vaatii lisävarusteen ACK 28, jotta se voidaan asentaa HBS 16:een. Sisältö 3 kpl 3 kpl 3 kpl 1 kpl 1 kpl Kupariputki, kauluksellinen Tasotiiviste Liitosmutteri 1 1/4" 3-tieventtiili Säätömoottori EP22-QN12 15

FI PutkiasennuksetHBS 16 Asennus tapahtuu seuraavasti: Tyhjennä tarvittaessa kattilavesi/lämmitysjärjestelmä. Shunttiventtiili (EP22-QN12) asennetaan menojohtoon HBS 16:n jälkeen ennen lämmitysjärjestelmän 1 ensimmäistä patteria. katso kuva. HUOM! Virheellisen asennuksen yhteydessä toiminta saattaa vaarantua. Shunttiventtiili, (EP22-QN12) Liitännät, Ø 28 mm Lämpö HBS 16 LEK Jäähdytys Kvs-arvo 8,5 16

FI Periaatekaavio HBS 16 ja - vaihtoventtiili, jäähdytys EP22-QN12 Jäähdytys Kyla A B AB RG10/ RE10 CP1 Överströmningsventiventtiili Ylivirtaus- Erf. säkerhetsutr. Vaadittu turvavarustus FQ1 FL1 BT 1 HBS AMS HEV Selvitys BT1 CP1 Lämpötilan anturi, ulko Puskurivaraaja UKV EP22-QN12 Vaihtoventtiili (jäähdytys/lämmitys) 17

FI Sähkökytkentä HBS 16 HUOM! Sähköasennukset saa tehdä vain valtuutettu sähköasentaja. Sähköasennukset ja johtimien veto on tehtävä voimassa olevien määräysten mukaisesti. HBS 16:n pitää olla jännitteetön :n asennuksen aikana. Kytkentäkaavio on tämän asennusohjeen lopussa. - - Valkoinen johdin (230 V signaali) jousiliittimeen X6:1a Sininen johdin (nolla) jousiliittimeen X6:6a Ohjelman asetukset Valitse "Huolto" valikosta 8.1.1, niin että pääset valikkoon 9.0 ja sen alivalikoihin. Valitse sitten "Päällä" valikossa 9.3.3 Jäähdytysjärjestelmä. Valikossa 8.2.4 ja 8.2.5 asetetaan jäähdytyksen käynnistys- ja pysäytysasetukset. Valikon 2.2.0 alavalikoissa tehdään muut jäähdytystä koskevat asetukset, esim. jäähdytyskäyrän valinta. Katso myös NIBE SPLIT asennus- ja huolto-ohjeet. Sähkökytkentä, X6 LEK Sähkökytkentä, X6 8 Sininen 7 6 5 4 Ruskea 3 2 Valkoinen 1 1. Lisävaruste ACK 28 asennetaan oheisen asennusohjeen mukaan. 2. Venttiilitoimilaite EP22-QN12 kytketään seuraavasti: - Ruskea johdin (230 V signaali) jousiliittimeen X6:3a 18

Elschema/Wiring diagram/elektrischer schaltplan/sähkökaavio 19

20

21

22

031954 AT KNV Energietechnik GmbH, Gahberggasse 11, 4861 Schörfling Tel: +43 (0)7662 8963-0 Fax: +43 (0)7662 8963-44 E-mail: mail@knv.at www.knv.at CH NIBE Wärmetechnik AG, Winterthurerstrasse 710, CH-8247 Flurlingen Tel: (52) 647 00 30 Fax: (52) 647 00 31 E-mail: info@nibe.ch www.nibe.ch CZ Druzstevni zavody Drazice s.r.o, Drazice 69, CZ - 294 71 Benatky nad Jizerou Tel: +420 326 373 801 Fax: +420 326 373 803 E-mail: nibe@nibe.cz www.nibe.cz DE NIBE Systemtechnik GmbH, Am Reiherpfahl 3, 29223 Celle Tel: 05141/7546-0 Fax: 05141/7546-99 E-mail: info@nibe.de www.nibe.de DK Vølund Varmeteknik A/S, Member of the Nibe Group, Brogårdsvej 7, 6920 Videbæk Tel: 97 17 20 33 Fax: 97 17 29 33 E-mail: info@volundvt.dk www.volundvt.dk FI NIBE Energy Systems OY, Juurakkotie 3, 01510 Vantaa Puh: 09-274 697 0 Fax: 09-274 697 40 E-mail: info@nibe.fi www.nibe.fi GB NIBE Energy Systems Ltd, 3C Broom Business Park, Bridge Way, Chesterfield S41 9QG Tel: 0845 095 1200 Fax: 0845 095 1201 E-mail: info@nibe.co.uk www.nibe.co.uk NL NIBE Energietechniek B.V., Postbus 2, NL-4797 ZG WILLEMSTAD (NB) Tel: 0168 477722 Fax: 0168 476998 E-mail: info@nibenl.nl www.nibenl.nl NO ABK AS, Brobekkveien 80, 0582 Oslo, Postadresse: Postboks 64 Vollebekk, 0516 Oslo Tel. sentralbord: +47 02320 E-mail: post@abkklima.no www.nibeenergysystems.no PL NIBE-BIAWAR Sp. z o. o. Aleja Jana Pawła II 57, 15-703 BIAŁYSTOK Tel: 085 662 84 90 Fax: 085 662 84 14 E-mail: sekretariat@biawar.com.pl www.biawar.com.pl RU "EVAN" 17, per. Boynovskiy, Nizhny Novgorod Tel./fax +7 831 419 57 06 E-mail: info@evan.ru www.nibe-evan.ru NIBE AB Sweden, Box 14, Hannabadsvägen 5, SE-285 21 Markaryd Tel: +46-(0)433-73 000 Fax: +46-(0)433-73 190 E-mail: info@nibe.se www.nibe.eu