Sauviinmäen tuulivoimahanke, Haapajärvi

Samankaltaiset tiedostot
( ,5 1 1,5 2 km

WindPRO version joulu 2012 Printed/Page :42 / 1. SHADOW - Main Result

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

WindPRO version joulu 2012 Printed/Page :47 / 1. SHADOW - Main Result

Metsälamminkankaan tuulivoimapuiston osayleiskaava

,0 Yes ,0 120, ,8

TM ETRS-TM35FIN-ETRS89 WTG

Rakennukset Varjostus "real case" h/a 0,5 1,5

Tynnyrivaara, OX2 Tuulivoimahanke. ( Layout 9 x N131 x HH145. Rakennukset Asuinrakennus Lomarakennus 9 x N131 x HH145 Varjostus 1 h/a 8 h/a 20 h/a

( ( OX2 Perkkiö. Rakennuskanta. Varjostus. 9 x N131 x HH145

( N117 x HH141 ( Honkajoki N117 x 9 x HH120 tv-alueet ( ( ( ( ( ( ( ( ( ( m. Honkajoki & Kankaanpää tuulivoimahankkeet

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

TM ETRS-TM35FIN-ETRS89 WTG

Lappfjärdin tuulivoimahanke, Kristiinankaupunki

Mallinnus perustuu Rambollin laatimaan päivättyyn välkemallinnusraporttiin,

Simon Seipimäen ja Tikkalan tuulivoimapuisto

Metsälamminkankaan tuulivoimapuiston osayleiskaava

V126 x 9 x HH ,3 db(a)


Välkemallinnus tehtiin WindPro 2.7 ohjelman SHADOW-moduulilla. Voimalaitosten sijoittelu oli päivätyn layoutin mukainen.

Ristiniityn ja Välikankaan tuulivoimapuistot, Haapajärvi

Calculation Results. windpro. Limakko ja Alajoki, Perho(1) Sound Level. Distances (m) WTG

Lakiakankaan tuulivoimahanke, Kristiinankaupunki, Isojoki ja Karijoki

Lakiakankaan tuulivoimahanke, Lakiakangas 1, Isojoki ja Karijoki

Soidinmäen tuulivoimahanke, Saarijärvi

Koiramäki tuulivoimahanke, Karstula

Ulppaanmäki tuulivoimahanke, Viitasaari

Hallakankaan tuulivoimahanke, Kyyjärvi

Merkkikallion tuulivoimapuisto

Vihisuo tuulivoimahanke, Karstula

Hautakankaan tuulivoimahanke, Kinnula

Hevosselän tuulivoimahanke, Tervola

Liite 1: Melu- ja varjostusmallinnukset

Vihisuo tuulivoimahanke, Karstula

Simon Seipimäen ja Tikkalan tuulivoimapuisto

Suolakankaan tuulivoimahanke, Kauhajoki

Lakiakangas I tuulivoimahanke, Karijoki

Loueen tuulivoimahanke, Tervola

KORPI-MATIN TUULIVOI- MAPUISTO, MERIKARVIA VÄLKEMALLINNUS

Vihisuo tuulivoimahanke, Karstula

Naulakankaan tuulivoimahanke, Vaala

Hevosselän tuulivoimahanke, Tervola

Simon Seipimäen ja Tikkalan tuulivoimapuisto

Mustakorpi tuulivoimahanke, Pyhtää

Hallakankaan tuulivoimahanke, Kyyjärvi

Ilosjoen tuulivoimahanke, Pihtipudas

wpd Finland Oy

IIN PAHKAKOSKEN TUULIVOIMAPUISTO

Rahkolan tuulivoimahanke, Haapavesi

HUMPPILAN - URJALAN TUULIVOIMAPUISTO VÄLKEMALLINNUS

YLIVIESKAN URAKKANEVAN TUULIVOIMAPUISTO

Korvennevan tuulivoimapuiston osayleiskaava

Nuolivaaran tuulipuiston melumallinnus

BILAGA 3E (1/11) Laadittu pvm. Projektinumero. Projektin nimi Asiakas Yhteyshenkilö. Mallinnusohjelman tiedot

Tyrnävän Kivimaan tuulipuisto Varjostusmallinnukset Projektinumero: WSP Finland Oy

Meluraportti, Honkamäki

Sastamalan Suodenniemen Kortekallion tuulivoima osayleiskaava-alueen arkeologinen inventointi

SIMON LEIPIÖN TUULIVOIMAPUISTON LAAJENNUS

KINKKULANMÄKI, HARTOLA TUULIVOIMALOIDEN VÄL- KEMALLINNUS

YLIVIESKAN URAKKANEVAN TUULIVOIMAPUISTO

wpd Finland Oy

TUULIVOIMAPUISTO MAANINKA. Välkeselvitys. Versio Päivämäärä Tekijät Hyväksytty Tiivistelmä

MASTOKANKAAN TUULIVOIMAPUISTO

Nuolivaaran tuulipuistohanke. Varjon vilkuntamallinnus

S U U N N IT T E L U JA T E K N IIK K A OX2 MERKKIKALLION TUULIVOIMAPUISTO

Mikonkeitaan tuulivoimahanke

Nuolivaaran tuulipuiston melumallinnus

Tyrnävän Kivimaan tuulipuisto Varjostusmallinnukset Projektinumero: WSP Finland Oy

Merkkikallion tuulivoimapuisto

BILAGA 2 LIITE 2. Buller- och skuggningsmodellering Melu- ja varjostusmallinnus

KONTTISUON TUULIVOI- MAPUISTO VÄLKEMALLINNUS

MASTOKANKAAN TUULIPUISTOHANKKEEN KAAVALUONNOS, VÄLKEMALLINNUS

Metsälamminkankaan tuulivoimapuiston varjostusvaikutusten arviointi (versio 2)

BILAGA 2 LIITE 2. Buller- och skuggningsmodellering Melu- ja varjostusmallinnus

Nuolivaaran tuulipuiston melumallinnus

Lakiakankaan tuulivoimahanke, Isojoki

KIIMASSUON TUULIVOIMA- PUISTO VÄLKEMALLINNUS, KAAVA 1

PALOKANKAAN TUULIVOIMAPUISTO

Intercon Energy Oy. Kaanaan tuulivoimapuiston varjostusvaikutusten arviointi

PALOKANKAAN TUULIVOIMAPUISTO

Meluraportti, Saunamaan tuulivoimapuisto

HUMPPILAN - URJALAN TUULIVOIMAPUISTO VÄLKEMALLINNUS

Pohjois-Satakunnan tuulivoimakaavoitushanke, Alahonkojoki, Kankaanpää

TAHKOLUODON MERITUU- LIPUISTO, PORI VÄLKEMALLINNUS

KIIMASSUON TUULIVOIMA- PUISTO VÄLKEMALLINNUKSEN PÄI- VITYS, KAAVA 1

KIIMASSUON TUULIVOIMA- PUISTO VÄLKEMALLINNUKSEN PÄI- VITYS, KAAVA 1

( ,5 1 1,5 2 km

PASKOONHARJUN TUULI- VOIMAPUISTO, TEUVA VÄLKEMALLINNUS

TUULIVOIMAHANKE, RAAHE VÄLKEMALLINNUS

Kaanaan tuulivoimapuiston meluvaikutusten arviointi

MASTOKANKAAN TUULIPUISTOHANKKEEN KAAVALUONNOS, MELUMALLINNUS

KANNUKSEN TUULIPUISTON MELUMALLINNUS

Transkriptio:

S U U N N IT T EL U JA T EK N IIK K A INFINERGIES FINLAND OY Sauviinmäen tuulivoimahanke, Haapajärvi Melu- ja varjostusmallinnukset Nordex N131 x 9 x HH144m FCG SUUNNITTELU JA TEKNIIKKA OY 13.11.2014 P21514

Melu- ja varjostusmallinnukset Nordex N131 x 9 x HH144m 1 (9) ne Märsylä 13.11.2014 Sisällysluettelo 1 MELU- JA VARJOSTUSMALLINNUKSEN TAVOITTEET... 2 2 LÄHTÖTIEDOT JA MENETELMÄT... 2 2.1 Melu... 2 2.1.1 Melumallinnus ISO 9613-2... 2 2.1.2 Matalataajuinen melumallinnus... 4 2.2 Varjostusmallinnus... 5 3 MELU- JA VARJOSTUSMALLINNUSTEN TULOKSET... 6 3.1 Melun laskentatulokset ISO 9613-2... 6 3.2 Matalataajuiset melutasot... 6 3.3 Varjostusmallinnusten tulokset... 7 4 JOHTOPÄÄTÖS... 8 Liitteet Liite 1: Melun leviämismallinnuksen tulokset ISO 9613-2... 1 Liite 2: Matalataajuisen melun rakennuskohtaiset arvot... 1 Liite 3: Varjostusmallinnusten tulokset real case... 1 FCG Suunnittelu ja tekniikka Oy Osmontie 34, PL 950, 00601 Helsinki Puh. 010 4090, fax 010 409 5001, www.fcg.fi Y-tunnus 2474031-0 Kotipaikka Helsinki

FCG SUUNNITTELU JA TEKNIIKKA OY 13.11.2014 Melu- ja varjostusmallinnukset Nordex N131 x 9 x HH144m 2 (9) 1 MELU- JA VARJOSTUSMALLINNUKSEN TAVOITTEET Haapajärven kunnan alueelle Sauviinmäelle suunnitteilla olevan tuulivoimahankkeen aiheuttamia melu- ja varjostusvaikutuksia on arvioitu laatimalla mallinnukset tuulivoimaloiden aiheuttamista äänenpainetasoista ja varjostuksista. Mallinnusten tavoitteena on osoittaa, kuinka laajalle alueelle kyseiset vaikutukset ulottuvat ja arvioida vaikutukset läheiselle asutukselle tai loma-asutukselle. Tuulivoimaloiden aiheuttamia meluvaikutuksia on arvioitu melun laskentamallin avulla, joiden mukaan on tehty melumallinnus WindPRO-ohjelmalla tuulivoimapuistosta. Tuulivoimaloiden aiheuttamat varjostusvaikutukset on mallinnettu WindPro-ohjelman SHADOW-moduulilla alustavien voimalanpaikkojen sijoitusten mukaisesti. Melu- ja varjostusmallinnukset on laatinut insinööri ne Märsylä FCG Suunnittelu ja tekniikka Oy:stä. 2 LÄHTÖTIEDOT JA MENETELMÄT 2.1 Melu 2.1.1 Melumallinnus ISO 9613-2 Tuulivoimaloiden aiheuttamat äänenpainetasot on mallinnettu WindPRO laskentaohjelmalla ISO 9613-2 standardin mukaisesti., jossa tuulen nopeutena käytettiin 8 m/s, ilman lämpötilana 15 C, ilmanpaineena 101,325 kpa sekä ilman suhteellisena kosteutena 70 %. Äänenpainetasot on mallinnettu käyttäen napakorkeuksiltaan 144 m korkeita voimaloita. Lähtötietoina eli referenssivoimalana on käytetty tuulivoimalaitosvalmistaja Nordex N131 voimalaa. Laskelmissa tuulivoimalan lähtömelutaso (L WA ) on 104,5 db. Laskenta on tehty 4,0 m maapinta-tasosta. Maanpinnan kovuutena käytettiin arvoa 0,4 Ympäristöhallinnon ohjeen 2/2014 Tuulivoimaloiden melun mallintaminen mukaisesti. Melumallinnuksen laskentatuloksia on havainnollistettu ns. leviämiskarttojen avulla. Leviämiskartta esittää melun leviämisen keskiäänitasokäyrät 5 db:n välein. Sauviinmäki N131 x 9 x H144m melu- ja varjostusmallinnusten selvitys.docx

FCG SUUNNITTELU JA TEKNIIKKA OY 13.11.2014 Melu- ja varjostusmallinnukset Nordex N131 x 9 x HH144m 3 (9) Taulukko 1. Mallinnusohjelma ja tuulivoimaloiden äänitehotasot sekä melun erityispiirteet MALLINNUSOHJELMAN TIEDOT Mallinnusohjelma ja versio: Mallinnusmenetelmä: ISO 9613-2 WindPRO version 2.9.269 TUULIVOIMALAN (TUULIVOIMALOIDEN TIEDOT) Tuulivoimalan valmistaja: Nordex Tyyppi: N131 Sarjanumero/t:- Nimellisteho:3,0 MW Napakorkeus:144m Roottorin halkaisija:131 Tornin tyyppi: hybridi Mahdollisuudet vaikuttaa tuulivoimalan melupäästöön käytön aikana ja sen vaikutus meluun Lapakulman säätö Pyörimisnopeus Muu, mikä Kyllä - db Kyllä - db - db Ei Ei - db AKUSTISET TIEDOT/LASKENNAN LÄHTÖTIEDOT Melupäästötiedot perustuvat dokumenttiin Nordex F008_246_A08_R01,; Revision 00, 2014-03-11. Oktaaveittain [Hz], db(a) 1/3-oktaaveittain [Hz], db(a) 63 83,0 10 33,9 125 84,6 1250 94,7 125 90,0 12,5 44,4 160 86,7 1600 94,8 250 94,8 16 52,1 200 88,6 2000 92,9 500 96,4 20 57,9 250 89,6 2500 92,3 1000 99,3 25 63,4 315 91,4 3150 91,9 2000 98,2 31,5 66,5 400 90,7 4000 91,5 4000 95,8 40 71,6 500 91,4 5000 89,4 8000 85,7 50 74,9 630 92,5 6300 84,6 63 78,4 800 94,2 8000 78,6 80 79,9 1000 94,8 10000 68,6 100 84,0 Melun erityispiirteiden mittaus ja havainnot: Kapeakaistaisuus / Tonaalisuus Impulssimaisuus Merkityksellinen sykintä (amplitu- dimodulaatio) Muu, Mikä: kyllä ei kyllä ei kyllä ei kyllä ei Sauviinmäki N131 x 9 x H144m melu- ja varjostusmallinnusten selvitys.docx

FCG SUUNNITTELU JA TEKNIIKKA OY 13.11.2014 Melu- ja varjostusmallinnukset Nordex N131 x 9 x HH144m 4 (9) Taulukko 2. Käytetyt mallinnusparametrit ISO 9613-2 laskelmissa sekä melulle altistuvat kohteet AKUSTISET TIEDOT/LASKENNAN LÄHTÖTIEDOT Laskenta korkeus ISO 9613-2: 4,0 m Suhteellinen kosteus Laskentaruudun koko [m m] 25x25 m Lämpötila 70 % Muu, mikä ja miksi: ISO 9613-2: 15 C Maastomallin lähde ja tarkkuus Maastomallin lähde: MML maastotietokanta Vaakaresoluutio:1,0 Pystyresoluutio:0,5 Maan- ja vedenpinnan absorption ja heijastuksen huomioiminen, käytetyt kertoimet ISO 9613-2 0,4 HUOM Ilmakehän stabiilius laskennassa/meteorologinen korjaus Neutraali, (0): Neutraali Muu, mikä ja miksi: Sääolosuhteiden huomiointi; laskennassa käytetty tuulen suunnat ja nopeus Tuulen suunta: 0-360 Tuulennopeus: 8 m/s Voimalan äänen suuntaavuus ja vaimentuminen Vapaa avaruus: kyllä Muu, mikä, miksi: Melulle altistuvat asukkaat ja kohteet > 35 db(a), lkm (ilman meluntorjuntaa/voimalan ohjausta) Asukkaat: 0 kpl Vapaa-ajan rakennukset: 0 kpl Hoito- ja oppilaitokset: 0 kpl Melun leviäminen virkistys- tai luonnonsuojelualueille Virkistysalueet: 0 kpl Luonnosuojelualueet: 0 kpl 2.1.2 Matalataajuinen melumallinnus Matalataajuinen melu laskettiin Ympäristöministeriön ohjeen 2/2014 mukaisin menetelmin käyttäen voimalavalmistajilta saatuja arvioita niiden äänitehotasoista (Nordex F008_246_A08_R01,; Revision 00, 2014-03-11). Ohje antaa menetelmän matalataajuisen melun laskentaan rakennusten ulkopuolelle. Sosiaali- ja terveysministeriön Asumisterveysohje 1/2003 antaa matalataajuiselle melulle ohjearvot asuinhuoneissa. Rakennusten sisälle kantautuva äänitaso arvioitiin tanskalaisen DSO1284 laskentaohjeen mukaisin ääneneristävyysarvoin ja tuloksia verrattiin ohjearvoihin. Sauviinmäki N131 x 9 x H144m melu- ja varjostusmallinnusten selvitys.docx

FCG SUUNNITTELU JA TEKNIIKKA OY 13.11.2014 Melu- ja varjostusmallinnukset Nordex N131 x 9 x HH144m 5 (9) 2.2 Varjostusmallinnus Tuulivoimaloiden varjostusvaikutuksia mallinnettiin WindPRO-ohjelman Shadowmoduulilla. Mallinnus tehtiin niin sanotulle todelliselle tilanteelle (real case). Mallinnuksessa ei ole huomioitu puuston suojaavaa vaikutusta. Auringon keskimääräiset paistetunnit perustuvat Jokioisen sääaseman pitkäaikaisiin mitattuihin säätietoihin 1981-2010. Laskentojen tuulen suunta ja nopeusjakaumana käytettiin Merra -tietoa hankealueen läheisyydeltä (E21,335 N62,000). Varjostusmallinnuksen tuloksia on havainnollistettu kartan avulla. Kartalla esitetään varjostusvaikutuksen (1, 8 ja 20 tuntia vuodessa) laajuus. Sen lisäksi mallinnuksessa on erikseen laskettu vaikutus tuulivoimapuistoalueen ympäristössä oleviin herkkiin kohteisiin. Laskennoissa varjot huomioidaan, jos aurinko on yli 3 astetta horisontin yläpuolella ja varjoksi lasketaan, kun siipi peittää vähintään 20 % auringosta. Varjostusmallin laskennassa on huomioitu hankealueen korkeustiedot, tuulivoimaloiden sijainnit esisuunnitelman mukaan, tuulivoimalan napakorkeudet ja roottorin halkaisija ja hankealueen aikavyöhyke. Mallinnuksessa otettiin huomioon auringon asema horisontissa eri kellon- ja vuodenaikoina, pilvisyys kuukausittain eli kuinka paljon aurinko paistaa ollessaan horisontin yläpuolella sekä tuulivoimalaitosten arvioitu vuotuinen käyntiaika. Varjostuksen tarkastelukorkeutena lähialueen asuin- tai lomarakennusten pihapiirissä käytettiin 2,0 metriä ja laskenta-alueen kokoa 5,0 x 5,0 metriä. Sauviinmäki N131 x 9 x H144m melu- ja varjostusmallinnusten selvitys.docx

FCG SUUNNITTELU JA TEKNIIKKA OY 13.11.2014 Melu- ja varjostusmallinnukset Nordex N131 x 9 x HH144m 6 (9) 3 MELU- JA VARJOSTUSMALLINNUSTEN TULOKSET 3.1 Melun laskentatulokset ISO 9613-2 Lähimpien asuinrakennusten pihapiirissä melutasot ovat laskelmien mukaan alle 40 db(a) ja lähimpien lomarakennusten kohdalla laskennallinen melutaso on myös alle 40 db(a). Katso tarkemmat laskentatulokset liitteestä 1. Kuva 1. Laskennalliset melutasot standardin ISO 9613-2 mukaisesti. 3.2 Matalataajuiset melutasot Matalataajuiset äänitasot ovat pääosin ulkonakin alle asuinhuoneiden sisäohjearvojen ja sisällä äänitaso jää kaikissa rakennuksissa alle ohjearvon kun huomioidaan rakenteiden ääneneristävys. Myös ihmisen keskimääräisen kuulokynnyksen alle jäädään kaikkien asuinrakennusten sisätiloissa. Koska oletusääneneristävyydellä äänitaso on huonoimmillaankin 10 db ohjearvon alapuolella, on ohjearvon ylittyminen epätodennäköistä huolimatta rakennusten eroista matalien äänien ääneneristävyydessä. Rakennuskohtaiset matalataajuiset äänitasot lähimpien rakennusten osalta on esitetty liitteessä 2. Sauviinmäki N131 x 9 x H144m melu- ja varjostusmallinnusten selvitys.docx

FCG SUUNNITTELU JA TEKNIIKKA OY 13.11.2014 Melu- ja varjostusmallinnukset Nordex N131 x 9 x HH144m 7 (9) 3.3 Varjostusmallinnusten tulokset Tuulivoimaloiden pohjoispuolella sijaitsee kaksi rakennusta, joissa varjostustunnit ovat real case -laskenta tulosten perusteella yli 1 tunti vuodessa. Varjostusvaikutukset ovat vähäisemmät, kun alueella kasvava puusto huomioidaan ja jää tällöin alle tuntiin vuodessa. Kuva 2. Laskennalliset varjostusmallinnuksen tulokset. Tarkemmat tulokset varjostusmallinnuksesta on esitetty liitteessä 3. Sauviinmäki N131 x 9 x H144m melu- ja varjostusmallinnusten selvitys.docx

FCG SUUNNITTELU JA TEKNIIKKA OY 13.11.2014 Melu- ja varjostusmallinnukset Nordex N131 x 9 x HH144m 8 (9) 4 JOHTOPÄÄTÖS Melun- ja varjostusmallinnustulosten perusteella tuulivoimahanke voidaan toteuttaa voimaloiden sijoitusten mukaisesti, eikä hankkeesta ole odotettavissa merkittävää haittaa melun tai varjostuksen osalta lähialueen asutukselle. FCG Suunnittelu ja tekniikka Oy ne Märsylä Laatija Jakob Kjellman Laaduntarkistus/Hyväksyjä Sauviinmäki N131 x 9 x H144m melu- ja varjostusmallinnusten selvitys.docx

FCG SUUNNITTELU JA TEKNIIKKA OY Melu- ja varjostusmallinnukset Nordex N131 x 9 x HH144m 13.11.2014 Liite 1 Liite 1: Melun leviämismallinnuksen tulokset ISO 9613-2 Sauviinmäki N131 x 9 x H144m melu- ja varjostusmallinnusten selvitys.docx

Tuulivoimalaitos Decibel 9 x Nordex N131 HH144m Melu ISO 9013-2; GF=0,4; z=4m; T=15C 35 db(a) 40 db(a) 45 db(a) Rakennusluokka Asuinrakennus Lomarakennus 0 0,25 0,5 0,75 1 km

Project: Sauviinmäen tuulivoimahanke Description: Haapajärvi Infinergies Finland Oy DECIBEL - Main Result Calculation: Sauviinmäki 9 x Nordex N131 hh144m Noise calculation model: ISO 9613-2 General Wind speed: 8,0 m/s Ground attenuation: General, Ground factor: 0,4 Meteorological coefficient, C0: 0,0 db Type of demand in calculation: 1: WTG noise is compared to demand (DK, DE, SE, NL etc.) Noise values in calculation: All noise values are mean values (Lwa) (Normal) Pure tones: Pure and Impulse tone penalty are added to WTG source noise Height above ground level, when no value in NSA object: 4,0 m Allow override of model height with height from NSA object Deviation from "official" noise demands. Negative is more restrictive, positive is less restrictive.: 0,0 db(a) WTGs New WTG WindPRO version 2.9.269 Nov 2013 Printed/Page 6.11.2014 14:40 / 1 Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 950 FI-00601 Helsinki +358104095666 ne Märsylä / janne.marsyla@fcg.fi Calculated: 6.11.2014 14:28/2.9.269 Scale 1:100 000 Noise sensitive area UTM (north)-etrs89 Zone: 35 WTG type Noise data East North Z Row Valid Manufact. Type-generator Power, Rotor Hub Creator Name Wind LwA,ref Pure data/description rated diameter height speed tones [m] [kw] [m] [m] [m/s] [db(a)] 1 421 754 7 073 648 135,2 WTG 9 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 USER Level - 104.5 db(a) - R00 8,0 104,5 0 db 2 421 462 7 074 279 139,0 WTG 8 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 USER Level - 104.5 db(a) - R00 8,0 104,5 0 db 3 421 336 7 073 099 131,3 WTG 7 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 USER Level - 104.5 db(a) - R00 8,0 104,5 0 db 4 420 976 7 073 653 132,4 WTG 6 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 USER Level - 104.5 db(a) - R00 8,0 104,5 0 db 5 420 309 7 073 313 123,3 WTG 5 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 USER Level - 104.5 db(a) - R00 8,0 104,5 0 db 6 420 681 7 074 237 137,2 WTG 4 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 USER Level - 104.5 db(a) - R00 8,0 104,5 0 db 7 419 577 7 073 767 127,8 WTG 3 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 USER Level - 104.5 db(a) - R00 8,0 104,5 0 db 8 419 285 7 074 714 142,5 WTG 2 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 USER Level - 104.5 db(a) - R00 8,0 104,5 0 db 9 417 934 7 075 376 140,0 WTG 1 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 USER Level - 104.5 db(a) - R00 8,0 104,5 0 db Calculation Results Sound Level Noise sensitive area UTM (north)-etrs89 Zone: 35 Demands Sound Level Demands fulfilled? No. Name East North Z Imission Noise From WTGs Distance to Noise height noise demand [m] [m] [db(a)] [db(a)] [m] A Asuinrakennus Vähäperäntie 265 418 740 7 076 817 125,6 4,0 40,0 27,4 1 235 Yes B Asuinrakennus Nivalantie 309 416 760 7 073 107 90,0 4,0 40,0 24,0 2 139 Yes C Asuinrakennus Settiläntie 45 416 434 7 074 028 90,7 4,0 40,0 24,8 1 605 Yes D Asuinrakennus Hilauksentie 34 416 091 7 074 574 91,6 4,0 40,0 24,2 1 600 Yes E Asuinrakennus Pysäysperäntie 151 416 221 7 075 959 95,0 4,0 40,0 24,8 1 400 Yes F Asuinrakennus Murronniityntie 51 418 678 7 071 724 105,0 4,0 40,0 26,5 1 757 Yes G Asuinrakennus Pihkapolku 15 417 786 7 072 241 105,0 4,0 40,0 25,4 1 895 Yes H Asuinrakennus Puronperäntie 285 423 526 7 072 705 135,1 4,0 40,0 26,9 1 514 Yes I Asuinrakennus Ouluntie 752 420 900 7 076 218 129,3 4,0 40,0 28,6 1 467 Yes Distances (m) WTG NSA 1 2 3 4 5 6 7 8 9 A 4373 3722 4535 3874 3839 3229 3163 2173 1651 B 5023 4846 4576 4251 3555 4081 2893 2993 2555 C 5334 5035 4990 4558 3941 4252 3154 2933 2017 D 5738 5379 5448 4971 4402 4602 3578 3197 2010 E 5996 5503 5860 5284 4869 4781 4008 3307 1809 F 3628 3779 2993 3000 2277 3214 2232 3051 3727 To be continued on next page... WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

Project: Sauviinmäen tuulivoimahanke Description: Haapajärvi Infinergies Finland Oy DECIBEL - Main Result Calculation: Sauviinmäki 9 x Nordex N131 hh144m WindPRO version 2.9.269 Nov 2013 Printed/Page 6.11.2014 14:40 / 2 Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 950 FI-00601 Helsinki +358104095666 ne Märsylä / janne.marsyla@fcg.fi Calculated: 6.11.2014 14:28/2.9.269...continued from previous page WTG NSA 1 2 3 4 5 6 7 8 9 G 4210 4203 3652 3489 2741 3516 2353 2892 3138 H 2007 2596 2225 2721 3274 3231 4089 4693 6197 I 2708 2019 3150 2566 2965 1993 2786 2207 3084 WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

Project: Sauviinmäen tuulivoimahanke Description: Haapajärvi Infinergies Finland Oy DECIBEL - Assumptions for noise calculation Calculation: Sauviinmäki 9 x Nordex N131 hh144m Noise calculation model: ISO 9613-2 General Wind speed: 8,0 m/s Ground attenuation: General, Ground factor: 0,4 Meteorological coefficient, C0: 0,0 db Type of demand in calculation: 1: WTG noise is compared to demand (DK, DE, SE, NL etc.) Noise values in calculation: All noise values are mean values (Lwa) (Normal) Pure tones: Pure and Impulse tone penalty are added to WTG source noise Height above ground level, when no value in NSA object: 4,0 m Allow override of model height with height from NSA object Deviation from "official" noise demands. Negative is more restrictive, positive is less restrictive.: 0,0 db(a) Octave data required Air absorption 63 125 250 500 1 000 2 000 4 000 8 000 [db/km] [db/km] [db/km] [db/km] [db/km] [db/km] [db/km] [db/km] 0,1 0,4 1,1 2,4 4,1 8,7 26,4 93,7 WindPRO version 2.9.269 Nov 2013 Printed/Page 6.11.2014 14:40 / 3 Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 950 FI-00601 Helsinki +358104095666 ne Märsylä / janne.marsyla@fcg.fi Calculated: 6.11.2014 14:28/2.9.269 WTG: NORDEX N131/3000 3000 131.0!O! Noise: Level - 104.5 db(a) - R00 Source Source/Date Creator Edited NORDEX 3.12.2013 USER 22.9.2014 11:38 F008_245_A03_R00, 21.11.2013 F008_246_A07_EN_R01 11.03.2014 Octave data Status Hub height Wind speed LwA,ref Pure tones 63 125 250 500 1000 2000 4000 8000 [m] [m/s] [db(a)] [db] [db] [db] [db] [db] [db] [db] [db] From Windcat 144,0 8,0 104,5 No 83,0 90,0 94,8 96,4 99,3 98,2 95,8 85,7 NSA: Asuinrakennus Vähäperäntie 265-A Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 40,0 db(a) Distance demand: NSA: Asuinrakennus Nivalantie 309-B Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 40,0 db(a) Distance demand: NSA: Asuinrakennus Settiläntie 45-C Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 40,0 db(a) Distance demand: NSA: Asuinrakennus Hilauksentie 34-D Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 40,0 db(a) Distance demand: WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

Project: Sauviinmäen tuulivoimahanke Description: Haapajärvi Infinergies Finland Oy DECIBEL - Assumptions for noise calculation Calculation: Sauviinmäki 9 x Nordex N131 hh144m WindPRO version 2.9.269 Nov 2013 Printed/Page 6.11.2014 14:40 / 4 Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 950 FI-00601 Helsinki +358104095666 ne Märsylä / janne.marsyla@fcg.fi Calculated: 6.11.2014 14:28/2.9.269 NSA: Asuinrakennus Pysäysperäntie 151-E Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 40,0 db(a) Distance demand: NSA: Asuinrakennus Murronniityntie 51-F Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 40,0 db(a) Distance demand: NSA: Asuinrakennus Pihkapolku 15-G Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 40,0 db(a) Distance demand: NSA: Asuinrakennus Puronperäntie 285-H Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 40,0 db(a) Distance demand: NSA: Asuinrakennus Ouluntie 752-I Predefined calculation standard: Imission height(a.g.l.): Use standard value from calculation model Noise demand: 40,0 db(a) Distance demand: WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

Project: Sauviinmäen tuulivoimahanke Description: Haapajärvi Infinergies Finland Oy DECIBEL - Map 8,0 m/s Calculation: Sauviinmäki 9 x Nordex N131 hh144m WindPRO version 2.9.269 Nov 2013 Printed/Page 6.11.2014 14:40 / 5 Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 950 FI-00601 Helsinki +358104095666 ne Märsylä / janne.marsyla@fcg.fi Calculated: 6.11.2014 14:28/2.9.269 Noise [db(a)] 35 40 45 0 500 1000 1500 2000 m Map: Maastokartat Haapajärvi, Print scale 1:47 000, Map center UTM (north)-etrs89 Zone: 35 East: 420 120 North: 7 073 883 New WTG Noise sensitive area Noise calculation model: ISO 9613-2 General. Wind speed: 8,0 m/s Height above sea level from active line object WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

FCG SUUNNITTELU JA TEKNIIKKA OY Melu- ja varjostusmallinnukset Nordex N131 x 9 x HH144m 13.11.2014 Liite 2 Liite 2: Matalataajuisen melun rakennuskohtaiset arvot Sauviinmäki N131 x 9 x H144m melu- ja varjostusmallinnusten selvitys.docx

FCG Suunnittelu ja Tekniikka Oy 3.11.2014 Terssin painottamaton äänitaso L eq db 100 90 80 70 60 50 40 30 20 10 0 Matalien taajuuksien äänitasot ulkona ja sisällä, A Asuinrakennus (Vähäperäntie 265), ääneneristävyys DSO1284 mukaan 20 25 31,5 40 50 63 80 100 125 160 200 Terssin keskitaajuus, Hz Äänitaso ulkona db Äänitaso sisällä db Stm Asumisterveysohje db Kuulokynnys matalilla taajuuksilla Tiedot rakennuksista ja voimaloista WindPro-raportista: Voimalat napakorkeus kpl Nordex N131_3000 3 MW, 144 m, 9 Laskenta on tehty ohjeen YM 2/2014 "Tuulivoimaloiden melun mallintaminen": Äänen geometrinen vaimeneminen pistelähteestä, maakerroin DSO1284 mukaan ja ilman absorptio ISO9613-1:1996 +15 C 70% RH. \\fcg.fi\common\projects\oul\p195\p19521_kuuden_tuulivoimaprojektin_ymp\työaineisto\windpro\desibel\haapajärvi\matalataajui nen_n131-3000x9hh144.xlsm Laskenta

FCG Suunnittelu ja Tekniikka Oy 3.11.2014 Terssin painottamaton äänitaso L eq db 100 90 80 70 60 50 40 30 20 10 0 Matalien taajuuksien äänitasot ulkona ja sisällä, B Asuinrakennus (Nivalantie 309), ääneneristävyys DSO1284 mukaan 20 25 31,5 40 50 63 80 100 125 160 200 Terssin keskitaajuus, Hz Äänitaso ulkona db Äänitaso sisällä db Stm Asumisterveysohje db Kuulokynnys matalilla taajuuksilla Tiedot rakennuksista ja voimaloista WindPro-raportista: Voimalat napakorkeus kpl Nordex N131_3000 3 MW, 144 m, 9 Laskenta on tehty ohjeen YM 2/2014 "Tuulivoimaloiden melun mallintaminen": Äänen geometrinen vaimeneminen pistelähteestä, maakerroin DSO1284 mukaan ja ilman absorptio ISO9613-1:1996 +15 C 70% RH. \\fcg.fi\common\projects\oul\p195\p19521_kuuden_tuulivoimaprojektin_ymp\työaineisto\windpro\desibel\haapajärvi\matalataajui nen_n131-3000x9hh144.xlsm Laskenta

FCG Suunnittelu ja Tekniikka Oy 3.11.2014 Terssin painottamaton äänitaso L eq db 100 90 80 70 60 50 40 30 20 10 0 Matalien taajuuksien äänitasot ulkona ja sisällä, C Asuinrakennus (Settiläntie 45), ääneneristävyys DSO1284 mukaan 20 25 31,5 40 50 63 80 100 125 160 200 Terssin keskitaajuus, Hz Äänitaso ulkona db Äänitaso sisällä db Stm Asumisterveysohje db Kuulokynnys matalilla taajuuksilla Tiedot rakennuksista ja voimaloista WindPro-raportista: Voimalat napakorkeus kpl Nordex N131_3000 3 MW, 144 m, 9 Laskenta on tehty ohjeen YM 2/2014 "Tuulivoimaloiden melun mallintaminen": Äänen geometrinen vaimeneminen pistelähteestä, maakerroin DSO1284 mukaan ja ilman absorptio ISO9613-1:1996 +15 C 70% RH. \\fcg.fi\common\projects\oul\p195\p19521_kuuden_tuulivoimaprojektin_ymp\työaineisto\windpro\desibel\haapajärvi\matalataajui nen_n131-3000x9hh144.xlsm Laskenta

FCG Suunnittelu ja Tekniikka Oy 3.11.2014 Terssin painottamaton äänitaso L eq db 100 90 80 70 60 50 40 30 20 10 0 Matalien taajuuksien äänitasot ulkona ja sisällä, D Asuinrakennus (Hilauksentie 34), ääneneristävyys DSO1284 mukaan 20 25 31,5 40 50 63 80 100 125 160 200 Terssin keskitaajuus, Hz Äänitaso ulkona db Äänitaso sisällä db Stm Asumisterveysohje db Kuulokynnys matalilla taajuuksilla Tiedot rakennuksista ja voimaloista WindPro-raportista: Voimalat napakorkeus kpl Nordex N131_3000 3 MW, 144 m, 9 Laskenta on tehty ohjeen YM 2/2014 "Tuulivoimaloiden melun mallintaminen": Äänen geometrinen vaimeneminen pistelähteestä, maakerroin DSO1284 mukaan ja ilman absorptio ISO9613-1:1996 +15 C 70% RH. \\fcg.fi\common\projects\oul\p195\p19521_kuuden_tuulivoimaprojektin_ymp\työaineisto\windpro\desibel\haapajärvi\matalataajui nen_n131-3000x9hh144.xlsm Laskenta

FCG Suunnittelu ja Tekniikka Oy 3.11.2014 Terssin painottamaton äänitaso L eq db 100 90 80 70 60 50 40 30 20 10 0 Matalien taajuuksien äänitasot ulkona ja sisällä, E Asuinrakennus (Pysäysperäntie 151), ääneneristävyys DSO1284 mukaan 20 25 31,5 40 50 63 80 100 125 160 200 Terssin keskitaajuus, Hz Äänitaso ulkona db Äänitaso sisällä db Stm Asumisterveysohje db Kuulokynnys matalilla taajuuksilla Tiedot rakennuksista ja voimaloista WindPro-raportista: Voimalat napakorkeus kpl Nordex N131_3000 3 MW, 144 m, 9 Laskenta on tehty ohjeen YM 2/2014 "Tuulivoimaloiden melun mallintaminen": Äänen geometrinen vaimeneminen pistelähteestä, maakerroin DSO1284 mukaan ja ilman absorptio ISO9613-1:1996 +15 C 70% RH. \\fcg.fi\common\projects\oul\p195\p19521_kuuden_tuulivoimaprojektin_ymp\työaineisto\windpro\desibel\haapajärvi\matalataajui nen_n131-3000x9hh144.xlsm Laskenta

FCG Suunnittelu ja Tekniikka Oy 3.11.2014 Terssin painottamaton äänitaso L eq db 100 90 80 70 60 50 40 30 20 10 0 Matalien taajuuksien äänitasot ulkona ja sisällä, F Asuinrakennus (Murronniityntie 51), ääneneristävyys DSO1284 mukaan 20 25 31,5 40 50 63 80 100 125 160 200 Terssin keskitaajuus, Hz Äänitaso ulkona db Äänitaso sisällä db Stm Asumisterveysohje db Kuulokynnys matalilla taajuuksilla Tiedot rakennuksista ja voimaloista WindPro-raportista: Voimalat napakorkeus kpl Nordex N131_3000 3 MW, 144 m, 9 Laskenta on tehty ohjeen YM 2/2014 "Tuulivoimaloiden melun mallintaminen": Äänen geometrinen vaimeneminen pistelähteestä, maakerroin DSO1284 mukaan ja ilman absorptio ISO9613-1:1996 +15 C 70% RH. \\fcg.fi\common\projects\oul\p195\p19521_kuuden_tuulivoimaprojektin_ymp\työaineisto\windpro\desibel\haapajärvi\matalataajui nen_n131-3000x9hh144.xlsm Laskenta

FCG Suunnittelu ja Tekniikka Oy 3.11.2014 Terssin painottamaton äänitaso L eq db 100 90 80 70 60 50 40 30 20 10 0 Matalien taajuuksien äänitasot ulkona ja sisällä, G Asuinrakennus (Pihkapolku 15), ääneneristävyys DSO1284 mukaan 20 25 31,5 40 50 63 80 100 125 160 200 Terssin keskitaajuus, Hz Äänitaso ulkona db Äänitaso sisällä db Stm Asumisterveysohje db Kuulokynnys matalilla taajuuksilla Tiedot rakennuksista ja voimaloista WindPro-raportista: Voimalat napakorkeus kpl Nordex N131_3000 3 MW, 144 m, 9 Laskenta on tehty ohjeen YM 2/2014 "Tuulivoimaloiden melun mallintaminen": Äänen geometrinen vaimeneminen pistelähteestä, maakerroin DSO1284 mukaan ja ilman absorptio ISO9613-1:1996 +15 C 70% RH. \\fcg.fi\common\projects\oul\p195\p19521_kuuden_tuulivoimaprojektin_ymp\työaineisto\windpro\desibel\haapajärvi\matalataajui nen_n131-3000x9hh144.xlsm Laskenta

FCG Suunnittelu ja Tekniikka Oy 3.11.2014 Terssin painottamaton äänitaso L eq db 100 90 80 70 60 50 40 30 20 10 0 Matalien taajuuksien äänitasot ulkona ja sisällä, H Asuinrakennus (Puronperäntie 285), ääneneristävyys DSO1284 mukaan 20 25 31,5 40 50 63 80 100 125 160 200 Terssin keskitaajuus, Hz Äänitaso ulkona db Äänitaso sisällä db Stm Asumisterveysohje db Kuulokynnys matalilla taajuuksilla Tiedot rakennuksista ja voimaloista WindPro-raportista: Voimalat napakorkeus kpl Nordex N131_3000 3 MW, 144 m, 9 Laskenta on tehty ohjeen YM 2/2014 "Tuulivoimaloiden melun mallintaminen": Äänen geometrinen vaimeneminen pistelähteestä, maakerroin DSO1284 mukaan ja ilman absorptio ISO9613-1:1996 +15 C 70% RH. \\fcg.fi\common\projects\oul\p195\p19521_kuuden_tuulivoimaprojektin_ymp\työaineisto\windpro\desibel\haapajärvi\matalataajui nen_n131-3000x9hh144.xlsm Laskenta

FCG Suunnittelu ja Tekniikka Oy 3.11.2014 Terssin painottamaton äänitaso L eq db 100 90 80 70 60 50 40 30 20 10 0 Matalien taajuuksien äänitasot ulkona ja sisällä, I Asuinrakennus (Ouluntie 752), ääneneristävyys DSO1284 mukaan 20 25 31,5 40 50 63 80 100 125 160 200 Terssin keskitaajuus, Hz Äänitaso ulkona db Äänitaso sisällä db Stm Asumisterveysohje db Kuulokynnys matalilla taajuuksilla Tiedot rakennuksista ja voimaloista WindPro-raportista: Voimalat napakorkeus kpl Nordex N131_3000 3 MW, 144 m, 9 Laskenta on tehty ohjeen YM 2/2014 "Tuulivoimaloiden melun mallintaminen": Äänen geometrinen vaimeneminen pistelähteestä, maakerroin DSO1284 mukaan ja ilman absorptio ISO9613-1:1996 +15 C 70% RH. \\fcg.fi\common\projects\oul\p195\p19521_kuuden_tuulivoimaprojektin_ymp\työaineisto\windpro\desibel\haapajärvi\matalataajui nen_n131-3000x9hh144.xlsm Laskenta

FCG SUUNNITTELU JA TEKNIIKKA OY Melu- ja varjostusmallinnukset Nordex N131 x 9 x HH144m 13.11.2014 Liite 3 Liite 3: Varjostusmallinnusten tulokset real case Sauviinmäki N131 x 9 x H144m melu- ja varjostusmallinnusten selvitys.docx

Tuulivoimalaitos Varjostus (real case) 1 h/a 8 h/a 20 h/a Rakennusluokka Asuinrakennus Lomarakennus 0 0,5 1 1,5 2 km

Project: Sauviinmäen Jakoistenkankaan tuulivoimahanke Description: Haapajärvi Infinergies Finland Oy SHADOW - Main Result Calculation: Haapajärvi 9 x Nordex N131, hh144m Assumptions for shadow calculations Maximum distance for influence Calculate only when more than 20 % of sun is covered by the blade Please look in WTG table WindPRO version 2.9.269 Nov 2013 Printed/Page 30.9.2014 11:55 / 1 Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 950 FI-00601 Helsinki +358104095666 ne Märsylä / janne.marsyla@fcg.fi Calculated: 30.9.2014 11:51/2.9.269 Minimum sun height over horizon for influence 3 Day step for calculation 1 days Time step for calculation 1 minutes Sunshine probability S (Average daily sunshine hours) [UMEA] Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1,02 2,84 3,78 6,14 8,62 9,94 7,42 5,13 4,32 3,43 1,58 0,96 Operational hours are calculated from WTGs in calculation and wind distribution: MERRA_basic_E24.668_N64.000 Operational time N NNE ENE E ESE SSE S SSW WSW W WNW NNW Sum 594 433 430 454 607 861 1 001 1 084 974 798 681 709 8 626 Idle start wind speed: Cut in wind speed from power curve A ZVI (Zones of Visual Influence) calculation is performed before flicker calculation so non visible WTG do not contribute to calculated flicker values. A WTG will be visible if it is visible from any part of the receiver window. The ZVI calculation is based on the following assumptions: Height contours used: Korkeuskäyrät Obstacles not used in calculation Eye height: 1,5 m Scale 1:100 000 Grid resolution: 10,0 m New WTG Shadow receptor WTGs UTM (north)-etrs89 Zone: 35 WTG type Shadow data East North Z Row Valid Manufact. Type-generator Power, rated Rotor diameter Hub height Calculation RPM data/description distance [m] [kw] [m] [m] [m] [RPM] 1 421 754 7 073 648 135,2 WTG 9 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 1 721 10,3 2 421 462 7 074 279 139,0 WTG 8 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 1 721 10,3 3 421 336 7 073 099 131,3 WTG 7 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 1 721 10,3 4 420 976 7 073 653 132,4 WTG 6 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 1 721 10,3 5 420 309 7 073 313 123,3 WTG 5 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 1 721 10,3 6 420 681 7 074 237 137,2 WTG 4 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 1 721 10,3 7 419 577 7 073 767 127,8 WTG 3 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 1 721 10,3 8 419 285 7 074 714 142,5 WTG 2 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 1 721 10,3 9 417 934 7 075 376 140,0 WTG 1 Yes NORDEX N131/3000-3 000 3 000 131,0 144,0 1 721 10,3 Shadow receptor-input UTM (north)-etrs89 Zone: 35 No. Name East North Z Width Height Height Degrees from Slope of Direction mode a.g.l. south cw window [m] [m] [m] [m] [ ] [ ] A Asuinrakennus Vähäperäntie 265 418 740 7 076 817 125,6 5,0 5,0 1,0 0,0 90,0 "Green house mode" B Asuinrakennus Nivalantie 309 416 760 7 073 107 90,0 5,0 5,0 1,0 0,0 90,0 "Green house mode" C Asuinrakennus Settiläntie 45 416 434 7 074 028 90,7 5,0 5,0 1,0 0,0 90,0 "Green house mode" D Asuinrakennus Hilauksentie 34 416 091 7 074 574 91,6 5,0 5,0 1,0 0,0 90,0 "Green house mode" E Asuinrakennus Pysäysperäntie 151 416 221 7 075 959 95,0 5,0 5,0 1,0 0,0 90,0 "Green house mode" F Asuinrakennus Murronniityntie 51 418 678 7 071 724 105,0 5,0 5,0 1,0 0,0 90,0 "Green house mode" G Asuinrakennus Pihkapolku 15 417 786 7 072 241 105,0 5,0 5,0 1,0 0,0 90,0 "Green house mode" H Asuinrakennus Puronperäntie 285 423 526 7 072 705 135,1 5,0 5,0 1,0 0,0 90,0 "Green house mode" I Asuinrakennus Ouluntie 752 420 900 7 076 218 129,3 5,0 5,0 1,0 0,0 90,0 "Green house mode" WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

Project: Sauviinmäen Jakoistenkankaan tuulivoimahanke Description: Haapajärvi Infinergies Finland Oy SHADOW - Main Result Calculation: Haapajärvi 9 x Nordex N131, hh144m Calculation Results Shadow receptor Shadow, expected values No. Name Shadow hours per year [h/year] A Asuinrakennus Vähäperäntie 265 1:21 B Asuinrakennus Nivalantie 309 0:00 C Asuinrakennus Settiläntie 45 0:00 D Asuinrakennus Hilauksentie 34 0:00 E Asuinrakennus Pysäysperäntie 151 0:00 F Asuinrakennus Murronniityntie 51 0:00 G Asuinrakennus Pihkapolku 15 0:00 H Asuinrakennus Puronperäntie 285 0:00 I Asuinrakennus Ouluntie 752 0:00 WindPRO version 2.9.269 Nov 2013 Printed/Page 30.9.2014 11:55 / 2 Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 950 FI-00601 Helsinki +358104095666 ne Märsylä / janne.marsyla@fcg.fi Calculated: 30.9.2014 11:51/2.9.269 Total amount of flickering on the shadow receptors caused by each WTG No. Name Worst case Expected [h/year] [h/year] 1 WTG 9 0:00 0:00 2 WTG 8 0:00 0:00 3 WTG 7 0:00 0:00 4 WTG 6 0:00 0:00 5 WTG 5 0:00 0:00 6 WTG 4 0:00 0:00 7 WTG 3 0:00 0:00 8 WTG 2 0:00 0:00 9 WTG 1 9:10 1:21 WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

Project: Sauviinmäen Jakoistenkankaan tuulivoimahanke Description: Haapajärvi Infinergies Finland Oy SHADOW - Calendar, graphical Calculation: Haapajärvi 9 x Nordex N131, hh144m WindPRO version 2.9.269 Nov 2013 Printed/Page 30.9.2014 11:55 / 3 Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 950 FI-00601 Helsinki +358104095666 ne Märsylä / janne.marsyla@fcg.fi Calculated: 30.9.2014 11:51/2.9.269 0:00 A: Asuinrakennus Vähäperäntie 265 B: Asuinrakennus Nivalantie 309 22:00 22:00 20:00 20:00 18:00 18:00 16:00 16:00 Time 14:00 12:00 Time 14:00 12:00 10:00 10:00 8:00 8:00 6:00 6:00 4:00 4:00 Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec C: Asuinrakennus Settiläntie 45 D: Asuinrakennus Hilauksentie 34 22:00 22:00 20:00 20:00 18:00 18:00 16:00 16:00 Time 14:00 12:00 Time 14:00 12:00 10:00 10:00 8:00 8:00 6:00 6:00 4:00 4:00 Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec E: Asuinrakennus Pysäysperäntie 151 F: Asuinrakennus Murronniityntie 51 22:00 22:00 20:00 20:00 18:00 18:00 16:00 16:00 Time 14:00 12:00 Time 14:00 12:00 10:00 10:00 8:00 8:00 6:00 6:00 4:00 4:00 Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec WTGs 9: WTG 1 WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

Project: Sauviinmäen Jakoistenkankaan tuulivoimahanke Description: Haapajärvi Infinergies Finland Oy SHADOW - Calendar, graphical Calculation: Haapajärvi 9 x Nordex N131, hh144m G: Asuinrakennus Pihkapolku 15 WindPRO version 2.9.269 Nov 2013 Printed/Page 30.9.2014 11:55 / 4 Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 950 FI-00601 Helsinki +358104095666 ne Märsylä / janne.marsyla@fcg.fi Calculated: 30.9.2014 11:51/2.9.269 H: Asuinrakennus Puronperäntie 285 22:00 22:00 20:00 20:00 18:00 18:00 16:00 16:00 Time 14:00 12:00 Time 14:00 12:00 10:00 10:00 8:00 8:00 6:00 6:00 4:00 4:00 Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec I: Asuinrakennus Ouluntie 752 22:00 20:00 18:00 16:00 Time 14:00 12:00 10:00 8:00 6:00 4:00 Feb Mar Apr May Jun Jul Month Aug Sep Oct Nov Dec WTGs WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk

WindPRO version 2.9.269 Nov 2013 Hours per year, real case 1 h/a 8 h/a 20 h/a 0 500 1000 1500 2000 m Map: Maastokartat Haapajärvi, Print scale 1:45 000, Map center UTM (north)-etrs89 Zone: 35 East: 420 100 North: 7 073 840 New WTG Shadow receptor Flicker map level: Korkeuskäyrät WindPRO is developed by EMD International A/S, Niels Jernesvej 10, DK-9220 Aalborg Ø, Tel. +45 96 35 44 44, Fax +45 96 35 44 46, e-mail: windpro@emd.dk Project: Sauviinmäen Jakoistenkankaan tuulivoimahanke Description: Haapajärvi Infinergies Finland Oy SHADOW - Map Calculation: Haapajärvi 9 x Nordex N131, hh144m Printed/Page 30.9.2014 11:55 / 5 Licensed user: FCG Suunnittelu ja tekniikka Oy Osmontie 34, PO Box 950 FI-00601 Helsinki +358104095666 ne Märsylä / janne.marsyla@fcg.fi Calculated: 30.9.2014 11:51/2.9.269