R L M E A R E M W C R Z R

Samankaltaiset tiedostot
Recair Oy Seppo Kanninen/sisäisen koulutuksen tiedosto

EC-huippuimuri. EC-huippuimuri

Ominaissähköteho FINVAC Ominaissähköteho. - rakentamismääräysten mukaan - ekosuunnitteluasetuksen mukaan. Pekka Mäkinen

CKD CKDR CKD/EW CKDR/EW

VTT EXPERT SERVICES OY

Roof extractor with excellent efficiency

UDT UDTX SUODATUSYKSIKÖT JA ILMANKÄSITTELYMODUULIT

KESKIPAKOPUHALTIMET JA INLINE IMURIT

FRF FRF/EW KATTOASENNETTAVAT KESKIPAKOISTOIMISET POISTOPUHALTIMET PYSTYSUORALLA ILMAN ULOSTULOLLA

SVE SVE/PLUS KESKIPAKOPUHALTIMET JA INLINE IMURIT

CSXR CSXRT CJSXR. Suurin virtausnopeus. Suurin mekaaninen teho. (rpm) (kw) m3/h min. maks. (kg)

VTT EXPERT SERVICES OY VTT EXPERT SERVICES LTD.

FB puhaltimet. Savujen, kaasujen ja partikkelien poistoon OUREX OY Mäkirinteentie 3, Kangasala Puh. (03) ourex.

SIZE 8 (EN 420:2003+A1:2009)

VTT EXPERT SERVICES OY VTT EXPERT SERVICES LTD.

Nimi: KV SILEO 200 M KANAVAPUHALLIN Tuotenro.: Version: 50 Hz

CJBX CJBX/AL. Vaihtoehto. Tilauskoodi CJBX 15/15 4. Tekniset ominaisuudet

SVE SVE/PLUS SVE/PLUS/EW LINJAAN ASENNETTAVA HILJAINEN POISTOPUHALLIN 40 MM:N ÄÄNIERISTYKSELLÄ HARJATTOMILLA E.C. -SÄHKÖMOOTTOREILLA BRUSHLESS

Nimi: KV SILEO 160 XL KANAVAPUHALLIN Tuotenro.: Version: 50 Hz

KATTOASENNETTAVAT KESKIPAKOISTOIMISET POISTOPUHALTIMET CRF CRF/EW

HFW KUUMASINKITYT PUTKIPUHALTIMET AERODYNAAMINEN JA OPTIMOITU SUUNNITTELU SUURTEHOINEN JA VÄHÄN KULUTTAVA KUUMASINKITTY HFW. IE3-MOOTTORIT > 7,5 kw

SVE/PLUS/EW 40 MM:N AKUSTINEN ERISTYS JA E.C. HARJATTOMAT SÄHKÖMOOTTORIT KORKEAN TEHOKKUUDEN LINJAAN ASENNETTAVAT PUHALTIMET

THT/HATCH AKSIAALISET PUHALTIMET JA KATTOASENNETTAVAT POISTOPUHALTIMET

Puhalluslämmitin. Warmex

ASETUKSET. (ETA:n kannalta merkityksellinen teksti) (6) Monet puhaltimet ovat osa rakennuksiin asennettuja ilmanvaihtojärjestelmiä.

Keskipaineiset, yhdeltä puolelta imevät keskipakopuhaltimet, joissa ulkoinen roottorimoottori.

Nimi: K SILEO 100 M KANAVAPUHALLIN Tuotenro.: 1001 Version: 50 Hz

AC-Aksiaalituuletin - HyBlade

AC-Aksiaalituuletin - HyBlade

VTT EXPERT SERVICES OY VTT EXPERT SERVICES LTD.

TESTAUSSELOSTE Nro. VTT-S

Aksiaalipuhaltimet kanava-asennukseen ARC

Tärkeimmät vaatimukset alkaen

SVE: Akustisen kääreen sisällä oleva linjaan asennettava hiljainen poistopuhallin

HiFEK-huippuimurit Korkean hyötysuhteen huippuimuri

EC-Radiaalituuletin.

25 Keskipakopuhaltimet molemminpuolin imevät

TEKNINEN OHJE ASENNUS KÄYTTÖ- JA HUOLTO-OHJE SUUNNITTELUOHJE SÄHKÖKYTKENTÄKAAVIOT ASENNUS- JA MITTAKUVAT HUOLTO-OHJE

TUOTETIEDOT VALLOX 51K MV VALLOX 51 MV

Kammiopuhallin EULK Puhallinkäyrästöt

Tekniset tiedot lyhyesti

AC-Aksiaalituuletin - HyBlade

LX 70. Ominaisuuksien mittaustulokset 1-kerroksinen 2-kerroksinen. Fyysiset ominaisuudet, nimellisarvot. Kalvon ominaisuudet

EC-Radiaalituuletin - RadiFit

Mitat. Tuotekoodi. Materiaalit ja pintakäsittely. lindab kattolaittet. GS23 liitäntälaatikolla H. GS23 yläosalla V

EC-Radiaalituuletin

EC-Radiaalituuletin

1m3/s = 3600m3/h 480Pa KRZ 27R-4D. 1,3kW KRZ 27R-6D 78. Äänentehotaso - oktaavikaistoittain. Viitteet. Varusteet Pa

VAAKA-ASENTEISET VAKIONOPEUSPUMPUT, 3x400V AS-, KN- ja KM-sarjat, laipalliset DN32-DN65. SC-KÄYTTÖVESIPUMPUT - AEP, LP ja ALP




35 Keskipakopuhaltimet molemminpuolin imevät

Uusi. Kammiopuhallin:

Technische Daten Technical data Tekniset tiedot Hawker perfect plus

Useimmat linnut elävät huippu teknisissä halleissä.

Nimi: K 315 L EC KANAVAPUHALLIN Tuotenro.: 2585

Tilauskoodi CJBD/EW /2 B T. Vaihtoehto E.C. TEKNOLOGIA

SVE SVE/PLUS SVE/EW HILJAINEN INLINE-PUHALLIN 40 MM:N ÄÄNIERISTYKSELLÄ ELEKTRONISILLA BRUSHLESS E.C. -MOOTTOREILLA BRUSHLESS

Maks. sähköteho (kw) Suurin virtausnopeus (m 3 /t)

400 C/2 h hihnakäyttöiset imuriyksiköt toimimaan palovyöhykkeen ulkopuolella, joissa reaktiosiipipyörät.

Puhallin: Ilmastointiyksiköt, joissa CBD-sarjan puhaltimet. Eteenpäin kaarevat siipipyörät valmistettu galvanoidusta teräslevystä.

Nimi: K 250 EC SILEO KANAVAPUHALLIN Tuotenro.: 78585

HifeK-huippuimurit Korkean hyötysuhteen huippuimuri

Metsälamminkankaan tuulivoimapuiston osayleiskaava

TULOILMA Ilmavirta l/s Ulkopuoliset paineet 150 Pa

27 Keskipakopuhaltimet molemminpuolin imevät

EC-Aksiaalituuletin - HyBlade

Lapuan myöntämä EU tuki SOLUTION asuinalueille omakoti- tai rivitaloa rakentaville

AC-Aksiaalituuletin. taivutetut siivet (S-rivi) Pyöreällä imukartiolla

Suomen kieli CAL DSR. Keskipakoispuhaltimet Asennus ja kunnossapito

AKKREDITOITU TESTAUSLABORATORIO ACCREDITED TESTING LABORATORY GRANT4COM OY

P ja PR. Muovipuhaltimet. Korroosionkestävät keskipakopuhaltimet OUREX OY Mäkirinteentie 3, Kangasala Puh. (03) ourex.

SÄHKÖKÄYTTÖISET UB 20 / UB 30

2. Keskusimu- ja suodatusjärjestelmät

Tynnyrivaara, OX2 Tuulivoimahanke. ( Layout 9 x N131 x HH145. Rakennukset Asuinrakennus Lomarakennus 9 x N131 x HH145 Varjostus 1 h/a 8 h/a 20 h/a

CONVERSION KITS FOR FRAMES MR8 AND MR9 INSTALLATION INSTRUCTIONS

25 Keskipakopuhaltimet molemminpuolin imevät

Tekniset tiedot AL124L680

Efficiency change over time

HiFEK-huippuimurit Korkean hyötysuhteen huippuimuri

Nimi: K 160 EC SILEO KANAVAPUHALLIN Tuotenro.: 77521

LVI-laitteiden määräykset ja luokitukset. Jorma Railio EKVÜ SuLVI- seminaari

( ,5 1 1,5 2 km

> Vesijäähdytteinen. Uniflair LE LDCV-LUCV kW. Vesijäähdytteiset vakioilmastointikoneet EC-puhaltimilla

Nimi: K SILEO 160 XL KANAVAPUHALLIN Tuotenro.: Version: 50 Hz

Choose Finland-Helsinki Valitse Finland-Helsinki

Lämmitysjärjestelmät

PUHALLINMELU YMPÄRISTÖMELUNLÄHTEENÄ - EPÄVARMUUSTEKIJÖITÄ WÄRTSILÄ FINLAND OY

( ( OX2 Perkkiö. Rakennuskanta. Varjostus. 9 x N131 x HH145

HiFEK huippuimurit Korkean hyötysuhteen huippuimuri

Korkean hyötysuhteen huippuimuri

Vaihteen valinta moottori - taajuusmuuttaja


WindPRO version joulu 2012 Printed/Page :42 / 1. SHADOW - Main Result

BK{ i. Tekniset tiedot ECO L. GTIN Sähkönumero Yleisvalaisin Ensto ECO320 IP44 LED10W/840

ART ART pairs PPE Cat. III SIZE XS (EN 420:2003+A1:2009) SV FI PL

RFTX, RKX Räjähdyssuojatut ATEX-sertifioidut radiaali- ja kanavapuhaltimet

TM ETRS-TM35FIN-ETRS89 WTG

Tilausvahvistus. Anttolan Urheilijat HENNA-RIIKKA HAIKONEN KUMMANNIEMENTIE 5 B RAHULA. Anttolan Urheilijat

Transkriptio:

Merkit "+" ja "-" Mikäli valintaluettelossa puhaltimen edessä on "+"-merkki on optimaalinen toimintapiste ulkopuolella puhaltimen optimaalisen käyttöalueen. Jos mahdollista valitse suurempi puhallin. Mikäli valintaluettelossa puhaltimen edessä on "-"-merkki on optimaalinen toimintapiste ulkopuolella puhaltimen optimaalisen käyttöalueen. Jos mahdollista valitse pienempi puhallin. Fan type 01 02 03 05 06-08 09 10 11-13 14-16 17-19 examples: R L M E 6-2 5 2 8-2 3-1 3 - A R E M 1 1-0 3 1 5-2 W - 1 3 - C R Z R 1 3-1 0 0 0 01... 03: fan - serie 05... 06: fan - execution 08... 11: fan - size 13... 14: motor - pole / efficiency - class. 16... 17: motor - size coded 19: motor manufacturer A = Siemens C = AC Motoren J = Simotop Techtop L = Lafert M = Domel AMCA Seal About AMCA The Air Movement and Control Association (AMCA) is an international, not-for-profit association of the world s manufacturers of fans, louvers, dampers, air curtains, air flow measurement devices, ducts, acoustic attenuators and other air system components. AMCA is dedicated to the certification of performance ratings on fans, louvers, dampers, air curtains, airflow measurement stations, acoustic attenuators, and other air system components for industrial, commercial, and residential markets.

Certified Rating Program (CRP) AMCA International's Certified Ratings Program (CRP) assures that a product line has been tested and rated in conformance with AMCA International's test standards and rating requirements. Each certified product line is subject to continuing check tests in AMCA International's laboratories. Participation in AMCA International's CRP is voluntary and open to members and non-members. AMCA International maintains an up-to-date listing of certified products. The Certified Ratings Programs is the most important function of the Association. Their purpose is to give the buyer, specifier, and user of air movement and control equipment assurance that published ratings are reliable and accurate. Manufacturers' catalogs and published ratings must be submitted to AMCA International's staff for approval before publication. The data in the column AMCA Seal show the standards according to which the respective fans have been tested and certified. - not AMCA licensed AP: SAP: AEP: AESP: FEG: FAP: FSAP: AMCA licensed for Air Performance AMCA licensed for Sound and Air Performance AMCA licensed for Air and Efficiency Performance AMCA licensed for Air, Efficiency and Sound Performance AMCA licensed for Efficiency Grade AMCA licensed for Efficiency Grade and Air Performance AMCA licensed for Efficiency Grade, Sound and Air Performance c = Flow velocity at the outlet Average speed of the conveying medium attributable latest dimension of the fan. For fans with casings (e.g. RZR 10) the area is defined as: - For Installation types A or C (i.e. with free outlet): Area over the cut-off - For installation types B or D (i.e. with ducted outlet) Area in the flange-cross section For plug fans without diffusers (e.g. RLM 50) the area is defined as the circumference multiplied with the outlet width of the blades (B 2 ).

The diameter of the impeller is defined as the diameter measured over the fan blades (blade tip diameter D 2 ). For plug fans with diffusers (e.g. RLM E6) the area is defined as the circumference multiplied with the outlet width of the blades (B 2 ). The diameter of the impeller is defined as the diameter measured over the shroud/back plate. V = Ilmamäärä dp t = Kokonaispaine Puhaltimen paine- ja imuaukolla vallitsevien kokonaispaineinetten erotus. pd 2 = Dynaaminen paine painepuolella Puhaltimen paineaukossa virtaavan kaasun keskimääräisen nopeuden ja tiheyden mukaan laskettu dynaaminen paine. dp fa = Staattinen paine Puhaltimen kokonaispaineen ja dynaamisen paineen erotus. P v = Painehäviö, imupuolen rakenne Asennushäviöt (keskipakopuhaltimille ilman kaapua,kammiopuhaltimet). Imupuolen häviöt (Keskipakopuhaltimet kaavulla) johtuen liian pienistä etäisyyksistä kammion seinään, sekä imupuolen haitoista esim. imupuolen suojaverkko, hihnapyörät, - suojat jne. Antamalla arvo " painehäviö tekijä" syötetyille arvoille, niin nämä häviöt huomioidaan. Ohjeet "painehäviötekijälle saat valitsemalla?. P w = Akseliteho Kertoo puhaltimen akselin tarvitseman tehon, ottamatta huomioon moottorin, taajuusmuuttajan tai invertterin tekemiä häviöitä. P n = Moottorin nimellisteho Kun valitset hihnakäyttöisen puhaltimen niin ohjelma valitsee automaattisesti yksinopeuksisen moottorin riittävällä marginaalilla. Jos tarvitaan toisen tyyppistä moottoria esim. kaksinopeuksista moottoria, IE3 moottoria jne., voidaan tämä valita Moottori -valikosta.

P 1S = Ottoteho Teho, joka ilmoittaa paljonko puhallin tai taajuusmuuttaja ottaa energialähteestä. Sisältää puhaltimen akselitehon, hihnavedon, moottorin ja/tai taajuusmuutajan tuottamat häviöt.. t = Kokonaishyötysuhde.Siipipyörän hyötysuhde (ilman käyttöä, moottoria ja taajuusmuttaajaa) Huom! Ei pidä sekoittaa puhaltimen stattiseen kokonaishyötysuhteeseen Määritelmä: ηt V Δp PW t fa = Staattinen hyötysuhde (puhaltimen) Tarkoittaa siipipyörän hyötysuhde sisältäen dynaamiset ja laakerihäviöt, muttei moottorin, hihnavedon ja mahdollisen taajuusmuuttajan. Määritelmä: ηt V Δpfa PW fas = Staattinen kokonaishyötysuhde. Takoittaa kokonaishyötusuhteen sis puhaltimen, moottorin, sekä mahdollisen hihnakäytön ja tai taajuusmuuttajan HUOM! Kutsutaan myös useasti kokonaishyötysuhteeksi mitä ohjelmassa on kutsuttu koknaishyötysuhteeksi. Kts yllä Määritelmä: ηfa S V Δp P1S fa

L wa = A-painotettu äänitehotaso imu/painepuolella DIN 45 635, osa 38, seuraavien kahdeksan tavan mukaan ohjelma mittaa eri asennuksille imu- tai painepuolelle arvon. L W1 Puhaltimen ääniteho L W2 Kotelon äänitehotaso L W3 Tulokanavaliitäntä ääniteho L W4 Poistokanavaliitäntä ääniteho L W5 Vapaa imu äänitehotaso L W6 Vapaa ulostulo äänitehotaso L W7 Koteloitu ja vapaa sisääntulo äänitehotaso L W8 Kotelo ja vapaa ulostulo äänitehotaso

n v = Puhaltimen nopeus (rpm) Hinta Hinnat hihnakäyttöisille puhaltimille sis. puhaltimen, moottorin,hihnan, joustavat liitokset jne. RZR 1_ sis. vain siipipyörän ja kaavun. Hihnaveto tyyppi RER 13 sis. kehyksen. Suoraveto puhaltimet esim. REM 1_ hinta sis. aina moottorin. Suoravetopuhaltimet esim. RZM 1_ hinta sis.aina moottorin ja kehyksen. Suoravetopuhaltimet esim. RLM sis.moottorin, kehyksen ja ilmamäärämittauyhteen. Tarvikehinnat saat klikkaamalla Optioner/Hinnat. SFP (Specific Fan Power) = Ominaissähköteho eli sähköverkosta otettu teho, joka tarvitaan yhden ilmakuution kuljettamiseen rakennuksen läpi sekunnissa. Se sisältää koko rakennuksen kaikkien tulo- ja poistopuhaltimien yhteenlasketun verkosta otetun sähkötehon jaettuna käsitellyllä ilmavirralla. Jakajana on aina suurempi ilmavirta( tulo tai poisto). ErP-tila 1/ Fans ErP-Direktiivi 2009/125/EG määrittää minimivaatukset puhaltimien energiatehokkuudeksi, joiden ottoteho vaihtelee 0,125-500 kw välillä. Nämä minimivaatimukset ovat sitovia 01.01.2013 lähtien (vaihe 1). 01.01.2015, vaihe 2 tiukentaa vaatimuksia edelleen. Vain puhaltimia, jotka täyttävät nämä vaatimukset saa myydä EU.n alueella. Tämä sarake näyttää myös kyseisen puhaltimen ERP- tila. Seuraavat merkinnät ovat mahdollisia: - ei täytäerp vaatimuksia 2015 2015 täyttää ERPvaatimukset 2015 2015 täyttää minimivaatimukset vuodelle 2015 Ei sovelleta ErP-Direktiivi ei koske puhallinta (esim. ATEX-Puhallin tai moottorin virrankulutus jää alle 0,125 kw) Hihnakäyttöisillä puhaltimilla ErP-Status määrittyy valintaohjelman mukaan Tätä määritettyä ErP-Status voidaan parantaa valitsemalla: - tehokkaampi moottori (esim. valitsemalla IE3 moottori IE 2 tilalle) - tehokkaampi moottori paremmalla hyötysuhteella - lattahihna kiilahihnan sijasta

2/ Ventilation units Huippuimurit ja koteloidut puhaltimet seuraavat EU komission direktiivi: 1253/2014 Direktiivi määrittelee vaadittavat hyötysuhteet näille puhaltimille. Ilmastointiyksiköt pitää noudattaa Ecodesign vaatimukset 01-01-2016 alkaen 01-01-2018 astuu vaihe 2 voimaan kovemmalla vaatimuksilla. Nämä päivämäärät asettavat rajan niille ilmastointilaitteille mitä saa myydä EU:n alueella. Tämä sarake näyttää myös kyseisen puhaltimen ERP- tila. Seuraavat merkinnät ovat mahdollisia: - ei täytäecodesign määräykset 2016 täyttää Ecodesign vaatimukset 2016 2018 täyttää Ecodesign 2018 vaatimukset Ei sovelleta EU direktiivi 1253/2014 ei täyty tälle yksikölle. (tämä on esimerkiksi savunkaasupuhaltimet mitkä ei saa käyttää muutoin)